Text
e j*
Fo.m4<18 U.S. NUCLEAR REGULATORY COMMISSION
" 88 10chR71 CERTIFICATE OF COMPUANCE j
For Radioactive Materials Packagse 1.(al C f to Number 1.(b) Revision No.
1.(c) t n No.
1.(d)
No. 1.tel Tot No. Pages
- 2. PRE AMBLE 2.lal This certificate is issued to set 6sfy Sectens 173.393e,173.394,173.395, and 173.396 of the Department of Transportation Hazardous Materials Regulations (49 CFR 170189 and 14 CFR 103) and Sections 146-19-10s and 146-19-100 of the Departreent of Transportation Dengerous Cargoes Regulations (46 CFR 146-149), as amended.
2.(b)
The packaging and contents described in itern s be6ow, rneets the safety standards set forth in Subpart C of Title 10. Code of Federal Regulations, Part 71," Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditens."
2.(c)
This certificate does not refieve the consignor from compliance with my requirement of the regulations of the U.S. Department of Transportation or other applicacie regulatory agencies, including the government of any country through er into which the package will be tronoported.
- 3. This certificate N issued on the basis of a safety analysis report of the pectage design or application-3.(a)
Prs,cated by (Name and address):
3.(b)
Title and identification of report or applicaten:
Advanced Medical Systema, Inc.
Picker Corporation application dated 1020 London Road December 19, 1974, as supplemented Cleveland, OH 44110 3.(es ooc =ei No.71-5796 4 CONDITIONS This cert 6ficate is conditional upon the fulfilling of the reavirements of Sute art O of to CFR 79, as applicable, and the conditions specified in item $ be60w.
S. Description of Packaging and Author 4:ed Contents, Model Number, Fiss le Ct.se, Other Conditions, and
References:
(a) Packaging (1) Model Nos.:
181375 and 181361 (2) Description Overpacks that provide impact and thermal protection for teletherapy head assemblies or source exchange assemblies.
The cubical overpacks consist of laminated 2x4 hardwood maple panels bolted together and covered with 16 gage steel panels.
Reinforcing steel straps and angles are welded together and spaced to limit the openings between them to less than 6 inches. Skid runners are provided to facilitate fork lift usage.
Dimensions of the Model No. 181375 are 37'x40"x41" with a maximum gross weight of 3,325 pounds. Dimensions of the Model No. U ~ 361 are 39"x39.5"x 48" with a maximum gross weight of 4,000 pounds.
(3) Drawings The packagings arn constructed in accordance with f.he following Picker Corporation Drawing Nos.:
(1) Model No. 181375: 0-18375, Rev. G; C-181368, Rev. 3; 0-181369, Rev. 3; and C-55156, Rev. B, with teletherapy heads Drawings Nos.; D-63790; C-46879, Rev. C; 0-184713; B-184704; 0-16424-E, Rev. 0; 0-164238 s Rev. F; and B-T60A-547.
810 6 2 3 070l.
,b Page 2 - Certificate No. 5796 - Revision'No. 4 - Docket No. 71-5796 5
(a) Packaging (continued)
(3) Drawings (continued)
(ii) Model No. 181361: 0-181361, Rev. 0; C-181357, Rev. D; ^-181:36, Rev. 0; B-181350, Rev. A, with source exchange assembly Drawing Nos. ; D-T60-478; B-13708-A; B-37092-A, Rev. C; C-13707-A, Rev. C:
B-14241A; D-T60-558;~and C-13709A or C-137098.
(b) Contents (1)_ Type and form of material (1)
Cobalt-60 sealed sources that meet the-requirements of special form as defined in 171.4(o) of 10 CFR Part 71.
The sources are to be packaged in secondary inner containers as described in 5(a)(3)(1) or 5(a)(3)(ii) Drawing Nos.
(ii) Cesium-137 in the form of cesium chloride encapsulated in saaled sources that meet the requirements of special form as defined in 171.4 o, of 10 CFR Part 71 or in sealed sources constructed and 5
inspected in accordance with Picker Corporatica letter dated January 4,.
1980. The sources are to be packaged in secondary inner containers as described in 5(a)(3)(ii) Drawing Nos.
(2) Maximum quantity of material per package (i)
For the contents described in 5(b)(1)(i).
13,680 curies, with a radioactive decay heat load not to exceed E00 watts.
(ii)
For the contents described in 5(b)(1)(ii).
2,200 curies, with a radioactive decay heat load not to exceed 17 watts.
6.
The packages authorized by this certificate are hereby approved for use under the general license provisions of 10 CFR 171.12(b).
7.
Expiration date: September 30, 1981.
e
+
n
'o
'{u
~
- Page -3.--' Certificate No. 5796 - Revision No. 4 - Docket No. 71-5796 REFERENCES'
. Picker Corporation application dated December 19, 1974.
Supplements dated: October 17, 1975; May 29 and August 15, 1979; and January 4, 1980.
FOR THE-U.S. NUCLEAR REGULAT0T.' CCtNISSION Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety
.JUN 0 91987 Date:
A' l
l 4
-_.w
.~w,.-..
,., -,.,..