Omaha Public Power District Docket No. 50-285 NOTICE OF VIOLATION As a result of the inspection conducted on January 1-31, 1981, and in accordance with the Interim Enforcement Policy, 45 FR 66754 (October 7, 1980), the following violations were identified:

1.

Radiation Protection Manual, Section 3.1.8.2 "Very High Radiation Area Controls," paragraph c. states, " Access door to very high radiation areas will be kept locked unless someone is actually inside or has continuous and direct control over the entrance to the area."

Contrary to the above, on January 21, 1981, the inspector observed that the door to room 68 (Cask Decon Room) was ajar and unattended.

This room is posted as a "Very High Radiation Area."

This is a Severity Level IV Violation (Supplement I.D.3).

2.

Raciation Protection Manual, Section 2.11.2, "Use of Protective Clothing,"

paragraph 2.11.2.1 states in part, " Specific articles of protective clothing are worn as specified for Control Areas.

The requirement for protective clothing will be listed on the RWP."

Contrary to the above, on January 21, 1981, the inspector observed one licensee employee in the new fuel receipt room who was not wearing a surgeon's cap as specified in RWP #20.

I This is a Severity Level V Violation (Supplement I.E.).

Pursuant to the provisions of 10 CFR Part 2.201, Omaha Public Power District is hereby required to submit to this office within twenty-five days of the date of this Notice, a written statement or explanation in reply, including:

(1) the corrective steps which have been taken and the results achieved; (2) the corrective step which will be taken to avoid further items of noncompliance; and (3) the date when full compliance will be achieved.

Under the authority of Section 182 of the Atomic Energy Act of 1954, as amended, this response shall oe submitted under oath or affirmation.

Date 2 l91/?/

/J kkhs v-G. L. Madsen, Chief, Reactor Operations and Nuclear Support Branch 810415 0 C)W

.