ML19350C321

From kanterella
Jump to navigation Jump to search
Responds to IE Bulletin 79-03A, Longitudinal Weld Defects in ASME SA-312,Type 304 Stainless Steel Pipe. Addl Info Will Be Provided by 810403,pending 810323 Completion of Westinghouse Investigation
ML19350C321
Person / Time
Site: Vogtle  
Issue date: 03/20/1981
From: Dutton D
GEORGIA POWER CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
GN-121, IEB-79-03A, IEB-79-3A, NUDOCS 8103310921
Download: ML19350C321 (2)


Text

.

/ /Q r

Georga Power Company Post Othce Box 4545 h

Atlanta, Georga 303o2 e Project m o mr* 4o4 522 e 3

.p co C

, '4/TD Southem Concany Semces, Inc.

N fQ Pat Ofnu Box 2625 g

B6 Atacama 352o2

\\,n U

4 TeiecNne 205 870-6ct1 4

' ?g

3 D

Cl h4 c?y%U'I March 20, 1981 g

/.

/

i 44 !; 4.a o.

United States Nuclear Regulatory Comission

REFERENCE:

Office of Inspection and Enforcement RII.

.1 pn Region II - Suite 3100

& 4; 50 f2'53 101 Marietta Street Atlanta, GA 30303 File: X7BC24 Log:

GN-121 Attention: Mr. James P. O'Reilly Gentlemen:

Further to our October 6,1980 letter, the following is submitted in response to your April 4,1980 letter concerning I.E. Bulletin 79-03A.

Westinghouse, our NSSS supplier, has completed their investigation with their suppliers and is express mailing their results to us on Monday, March 23, 1981.

Georais Power Company will provide the additional infomation con-cerning tisis bulletin by April 3,1981 if this is acceptable to you.

We apologize for any inconvenience the delay in coordinating the responses to this bulletin may have caused. We have improved our " tickler file" to help assure that suspense dates are complied with.

f r

m,Du tonNMN Doug Project aeneral Manager CWH:tp xc:

U. S. Nuclear Regulatory Comission Office of Inspection and Enforcement Division of Reactor Operations Inspection Washington, DC

!810333oqg[

Mr. James P. O'Reilly RII: JP'J, 50-424/50-425 March 20, 1981 Page 2 xc:

J. H. Miller, Jr.

W. E. Ehrensperger F. G. Mitchell, Jr.

R. J. Kelly R.. E. Conway R. W. Staffa H. C_ Nix K. M. Gillespie C. W. Hayes E. D. Groover D. L. McCrary R. A. Thomas J. A. Bailey M. Z. Jeric J. fi. Purucker J. L. Vota l

I i

i I

l l

i l

,e