ML19350C209

From kanterella
Jump to navigation Jump to search
Forwards LER 81-004/03L-0
Date released: 12/30/2019 Download: ML19350C209


LER 81-004/03L-0:on 810227,diesel Fire Pump Battery Bank Surveillance Test Found Not Completed within Grace Period. Caused by Failure to Notify Supervisor That Procedure Could Not Be Completed During Shift
ML19350C210
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 03/25/1981
From: Bramlett L
ARKANSAS POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19350C210 (1)
Forwards LER 81-004/03L-0
ML19350C208
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 03/25/1981
From: Trimble D
ARKANSAS POWER & LIGHT CO.
To: SEYFRIT K V
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19350C208 (1)