YANKEE ATOMIC ELECTRIC COMPANY
* ~
X*
2.C.2.1
-.v,
K 4 ).-
1677 Worcester Kood, from ag6am, Mossochusetts 01701 FYR 81-44
'Y4mxes fa4 March 20, 1981 N
MAR 3 01981 >
Ws.NxuAn nouwors /g.31 coawsuon United Sta tes Nuclear Regula tory Commission j
S Wash ington, D. C.
20555 in D
Attention:
Mr. Paul S. Check, Assistant Directer for Plant Systems Division of Systems Integration j
Office of Nuclear Reactor Regula tion
References:
(a)
License No. DPR-3 (Docket No. 50-29)
(b)
License No. DPR-36 (Docket No.59-309)
(c) USNRC Letter to YAEC, dated June 26, 1980,
Subject:
Prediction Requirements of LOFT Small Break Test L3-6 (d)
RELAPS/ MOD 1, NUREG/CR-1826, November 1980 (Draft)
Subject:
LOFT L3-6 Post-Test Prediction
Dear Sir:
Attached please find the Yankee Atomic Electric Company's Post-Test Prediction and Comparison With Test Data for LOFT Small Break Experiment L3-6.
The prediction was made using RELAP 5/ Mod 1.
This prediction is an Appendix to the RELAP 4/ Mod.. prediction submitted on March 3, 1981.
We trus t th is information is acceptable to you; however, should you have any ques tions, please contact us.
Very truly yours,
YANKEE ATOMIC ELECTRIC COMPANY J, A. Kay
-Senior Engineer - Licensing JNL/jgh Att achme nt r
BN6'S'310.