Forwards Safety Evaluation Approving 800507 Revised ECCS Analysis.Nrc 781220 Exemption Satisfied & Terminated
ML19350B446
Person / Time
Site: Trojan File:Portland General Electric icon.png
Issue date: 03/05/1981
From: Clark R
Office of Nuclear Reactor Regulation
To: Withers B
PORTLAND GENERAL ELECTRIC CO.
Shared Package
ML19350B447 List:
References
TAC-07718, TAC-7718, NUDOCS 8103200557
Download: ML19350B446 (2)


Text

i

~

go ** c,D UNITED STATES i

1 NUCLE AR REGUL ATORY CO.a.".*ISSION

{

WAsm4GTON. D. C. 20555 C 4 cay,

3

%, %.....s March 5, 1981 Docket No. 50-34.+

Mr. Bart D. Withers Vice President Nuclear Portland General Electric Company 121 S. W. 5almon Street Portland, Oregon 97204

Dear Mr. Withers:

We have completed our review of the revised ECCS analysis provided with your letter of May 7, 1980. This reanalysis of ECCS performance superseced the reanalysis you submittea on March lb,1979 in compliance with the NRC Exemption issued on December 20, 1978, relating to tne zirconium-water error discovered in the Westinghouse evaluation model.

As aiscussed in detail in the enclosed Safety Evaluation, your revised ECCS performance evaluation nas ceen made using an NRC-approved evaluation model which satisfies ti.

requirements of 10 CFR 50.46 and 10 CFR 50, Appenaix K.

Tne reanalysis was cone assuming that 6% of tne steam generator tubes are plugged, with a maximum total peaxing factor of 2.32, resulting in a peak clad. temperature of 19700 F.

No changes to the Technical Specifica-tions are required.

1 The NRC Exemption of December 20, 19/8 has been satisfied and is hereby terminated.

dincerely, M '. 6 ~.I Hobert A. Clark, Chief l

Operating Reactors Branch #3 Division of Licensing l

Enclosure:

Safety Evaluation of Trojan Revised tCCS Analysis

~

g

'm g cc w/ enclosure:

S See next page b

ffr, ih 1

~/ 6U.

,U

$q MnR 111981> 7e e

p j

u.s. g g,uca 4

e _

.a l

8108200 %

Portland General Electric Company cc:

Mr. J. W. Durham, Esquire Senior Vice' President and Corporate Counsel Portland General Electric Coceany 121 S. W. Salmon Street Portland, Oregon 97204 Multnomah County Library Social Science aid Science Departcent 801 S.W.10th Avenue Portland, Oregon 97205 Michael Malmros, Resident Inspector U. S. Nuclear Regulatory Commission Trojan Nuclear Plant P. O. Box 0 Rainier, Oregen 97048 Robert M. Hunt, Chairman Board of County Commissioners Columbia County St. Helens, Oregon 97501 Director, Criteria and Standards Division Office of Radiation Programs (ANR-460)