ML19350B360

From kanterella
Jump to navigation Jump to search
Forwards IE Info Notice 81-07, Potential Problem W/Water-Soluble Purge Dam Matls Used During Inert Gas Welding. No Response Required
ML19350B360
Person / Time
Site: Bailly
Issue date: 03/16/1981
From: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Shorb E
NORTHERN INDIANA PUBLIC SERVICE CO.
References
NUDOCS 8103200328
Download: ML19350B360 (2)


Text

--. _

. as ut

'~

/

i' UNITED STATES 8

'n NUCLEAR REGULATORY COMMISSION E

REGION lli b[

790 ROOSEVELT ROAD g

GLEN ELLYN, ILLINOIS 80137 o

March 16, 1981 Gentlemen:

This IE Information Notice No. 81-07 is provided as an early notifi-cation of a possibly significant matter.

It is expected that recipients will review the information for possible applicability to their facilities.

No specific action or response is requested.at this time.

If further NRC evaluations so indicate, an IE Circular or Bulletin will be issued to recommend or request specific licensee actions.

If you have questions regarding this matter, please contact. this office.

Sincerely, s

k

. / h James G. Keppler U

Director

Enclosure:

IE Information Notice No. 81-07 slossoo Y

~

v,-,wna q..av~r_g, 4

ne-e,--

g n,

=

g

~ _

i i

J i

Docket No. 50-367 Northern Indiana'Public Service Company (TTN:

Mr. Eugene M. Shorb Senior Vice President 5265 Hohman Avenue

Hammond,

' 46325 cc encl:

atral Files AD/ Licensing AD/ Operating Reactors.

PDR Loca1.PDR NSIC

. TIC Mary Jo Murray, Office of l Assistant Attorney General.

1 i

e O) ge i s is,/ A,~>

Q

.'**r j}

&g/

=

SSYNS No.: 6835 Accession No.:

8011040267 IN 81-07 UNITED STATES NUCLEAR REGULATORY C0f t11SSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C. 20555 March 16, 1981 IE Information Notice No. 81-07:

POTENTIAL PROBLEM WITH WATER-SOLUBLE PURGE DAM MATERIALS USED DURTNG INERT GAS WELDING Description of Circumstances:

Recent experiences with water-soluble purge dam materials at several nuclear construction sites have shown the need to develop welding procedures that address the potential for thermally decomposing the purge dam material during inert gas welding or post-weld heat treatment operations.

Specifically, polyvinyl alcohol film manufactured by Chris-Craft Industries was the purge dam material used at these construction sites.

The decomposition of this purge dam material at elevated temperatures causes the material to lose its solubility in water. As a result, the purge dam material cannot be completely dissolved during subsequent piping system flushing and cleaning operations.

The failure of this material to completely dissolve could cause significant problems during reactor plant operation.

Specimens of polyvinyl alcohol film were recently obtained from the Mono-Sol Division of Chris-Craft Industries and tested at Franklin Research Center (FRC) to determine, among other things, the threshold temperature at which the material becomes insoluble in water.

The results of this test program indicate that (1) the solubility of the purge dam material in water rapidly approaches zero if the material is heated and held at temperatures in excess of 300 F; (2) the purge dam material hardens and becomes difficult to break if subject to temperatures in the range of 300 F to 400 F, and becomes brittle if heated to 450 F; and (3) purge dam material heated above its threshold temperature is not soluble in commonly used laboratory solvents.

The inde-pendent testing laboratory (FRC) therefore concludes that the Mono-Sol poly-vinyl alcohol film will not dissolve during aqueous flushing of the system if the material has been heated to temperatures in excess of 300 F.

Recommended Actions for Holders of Operating Licenses and Construction Permits:

It is recommended that all welding operations involving polyvinyl alcohol purge dam materials be governed by procedures that require the material to be located in areas that are sufficiently removed from heat so that the temperature of the material does not reach 300 F.

No written response to this information notice is required.

If you reouire additional information with regard to this subject, please contact the appropriate NRC Regional Office.

Attachment:

Recently issued IE Information Notices

s -

Attachment IN 81-07 March 16, 1981 RECENTLY ISSUED IE INFORMATION NOTICES Information Date of Notice No.

Subject Issue Issued to i

81-06 Failure of ITE Model 3/11/81 All power reactor K-600 Circuit Breaker facilities with an OL or CP 81-05 Cegraded DC System at 3/13/81 All power reactor Palisades facilities with an OL or CP 81-04 Cracking in Main Steam 2/27/81 All power reactor Lines facilities with an OL 81-03 Checklist for Licensees 2/12/81 All power reactor Making No*.ifications of facilities w'th an Significant Events in OL Accordance with 10 CFR 50.72 81-02 Transportation of 1/23/81 All Radiography Radiography Devices licensees 81-01 Possible Failures of 1/16/81 All power reactor General Electric Type facilities with an HFA Relays OL or CP.

80-45 Pote-tial Failure.of 12/17/80 All PWR facilities BWP Sackup Manual Scram with an OL or CP Capability 80-44 Actuation of ECCS in the 12/16/80 All PWR facilities Pacirculation Mode While with an OL or CP in Hot Shutdown 80-32 Failures of the Continuous 12/5/80 All power reactor Water Level Monitor for facilities with an the Scram Discharge Volume OL or CP at.Dresden Unit No. 2 80-42 E*fect of Radiation '..

11/24/80 All power reactor

~

Hy6roolic Snubber F;eio facilities with an r

OL or CP

.. ~ - -

0L = Operating Licenses CP = Construction Permits