Text
w-EI)p(~%j 8
UNITED STATES NUCLEAR REGULATORY COMMISSION
'e \\
aC REGION I 3M O
631 PARK AVENUE Y
KING OF PRUSSIA, PENNSYLVANIA 19406 o
pp "
MAR 4 1981 D
s Docket No. 50-289 Metropolitan Edison Company
//
f4 i
ATTN:
Mr. H. D. Hukill f,""lR T3
\\@H."* g% d h sJ Vice President and Director of TMI-1 P. O. Box 480
\\
Middletown, Pennsylvania 17057 O.
v s
- g\\
/ f w
Gentlemen:
IE Bulletin No. 81-01, " Surveillance of Mechanical Snubbers," transmitted to you on January 27, 1981, has been revised to change the identification of the power reactor facilities with construction permits to which the Bulletin is applicable.
This change does not affect your requirements with respect to the original Bulletin.
As a result, the enclosed revised pages 5 and 6, are forwarded to you for information.
If you desire additional information regarding this matter, please contact this office.
Sincerely, CL o
oy e H. Grier Director
Enclosures:
Revised pages 5 and 6 of IE Bulletin 81-01 and List of Recently Issued IE Bulletins i
CONTACT:
D. L. Caphton l
(215-337-5266) l l
l cc w/encis:
R. J. Toole, Manacjer, TMI-1 L. W. Harding, TMI-l Licensing Supervisor E. G. Wallace, PWR Licensing Manager J. B. Liberman, Esquire l
G. F. Trowbridge, Esquire Ms. Mary V. Southard, Chairperson, Citizens for a Safe Environment 8103200112
SSINS No.:
6320 Accession No.:
8005050075 IE5 81-01 UNITED STATES NUCLEAR REG'JLATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.
20555 January 27, 1981 IE Bulletin No. 81-01:
SURVEILLANCE OF MECHANICAL SNU53ERS Description of Circumstances:
Several instances of failures of mechanical snubbers supplied by International Nuclear Safeguards Corporation (!NC) have been identified that indicate possible deficiencies in these snubbers. A summary of the failures that have occurred is provided below:
1.
On August 9, 1974, the Tennessee Valley Authority submitted event report BFAO-50-260/741W identifyirig 11 of 14 INC Model MSVA-1A snubbers that were found inoperable on Browns Ferry Nuclear Power S:.ation Unit 2 and subsequently ident'fied 5 of 14 inoperable units on Browns Ferry Nuclear Power Unit No 3.
All of these units were found to be frozen, and the cause was attri h ted to a failure to lubricate the parts during assembly.
The faile*...uobers were replaced with new units produced by the same manufacturer.
2.
On April 12, 1976, the St. Lucie Plant Unit 1 facility of Florida Power and Light Corporation submitted event report No. 50-335-76-9 wherein five INC Model MSVA-1 snubbers were identified as inoperable because they were found to be frozen. The failures were caused by oxidation on the internals
.and by; improper assembly. All.INC mechanical snubbers were replaced with units produced by another manufacturer.
~
~
3.
On April 8, 1977, Iowa Electric Light and Power Company submitted event report No. 77-23 for the Duane Arnold Energy Center facility that identi-fled 13 INC Model IMSVA-1 Type AS snubbers to be frozen; the cause of failure was attributed to large amounts of interior oxidation. The units were replaced with those produced by another manufacturer.
4.
O'n December 5,1979, personnel from the Nuclear Regulatory Commission visited Department of Energy (DOE) facilities at Richland, Washington, to obtain information on DOE experience with INC snubbers at the Fast Flux Test Facility (FFTF). The DOE-owned FFTF was equipped with more than 4,000 mechanical pipe restraints (snubbers) supplied by INC.
In 1978.
FFTF examined more than wu from their installation and DUPLICATE DOCUMENT were frozen. The plant was seen no service and had bee Entire document previously environments for 1 to 2 yea entered into syste:n under:
00050$00l$
ANO Attacheent:
Recently issued IE bullitins
~