y (&

[

UNITED STATES c(

NUCLEAR REGULATORY COMMISSION y

",'gE W ASHINGTON, D. C. 20555 g

j

%y... 4 Docket No. 50-358 ~

NOV 18 SD Mr. Earl A. Borgmann Vice President - Engineering Cincinnati Gas & Electric Company P. O. Box 960 Cincinnati, Ohio 45201

Dear Mr. Borgmann:

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION As a result of the occurrence of a moderate earthquake approximately 45 miles southeast of the Zinner site near Sharpsburg, Kentucky on July 27, 1980, the staff will issue a SER supplement to the seismology section providing a complete discussion of this earthquake.

In order to obtain the information required to issue this supplement, we have prepared the following questions. Upon receipt of your response, we estimate that it will take 30-60 days to complete our review and provide the supplement.

Please advise us as to when you will be able to respond.

We will be available to discuss these questions at a meeting or by telephone conference call.

Sincerely,.

)

RoMt L. T sco Assistant Director for Licensing Division of Licensing

Enclosure:

Request for Additional Information cc w/ enclosure:

See next page E

8012010053

a

.~.

Mr. Earl A. Borgmann Vice President - Engineering Cincinnati Gas & Electric Company D 18 %

P. O. Box 960 Cincinnati, Ohio 45201 cc: Troy B. Cnnner, Jr., Esq.

Leah S. Kosik, Esq.

Conner, Mo. ire & Corber 3454 Cornell Place 1747 Pennsylvania Avenue, N.W.

Cincinnati, Ohio 45220 Washington, D.C.

20006 W. Peter Heile, Esq.

Mr. William J. Moran Assistant City Solicitor General Counsel Room 214, City Hall Cincinnati Gas & Electric Company

' Cincinnati, Ohio 45220 P. O. Box 960 Cincinnati, Ohio 45201 John D. Woliver, Esq.

Clermont County Comunity Council g

Mr. William G. Porter, Jr.

Box 181 Porter, Stanley, Arthur Batavia Ohio 45103 and Platt 37 West Broad Street Mrs. Mary Reder Columbus, Ohio 43215 Box 270, Rt. 2 Mr. James D. Flynn, Manager Licensing Environmentai Affairs Andrew B. Dennison, Esq.

Cincinnati Gas & Electric Company 200 Main Street P. O. Box 960 Batavia, Ohio 45103 Cincinnati, Ohio 45201 Robert A. Jones, Esq.

David Martin, Esq.

Prosecuting Attorney of Clennont Office of the Attorney General County, Ohio 209 St. Clair Street 154 Main Street First Floor Batavia, Ohio 45103 Frankfort, Kentucky 40601 Resident Inspector /Zimmer Dr. Frank F. Hooper RFD 1. P. O. Box 2021 School of Natural Resources U. S. Route 52 University of Michigan Moscow, Ohio 45153 Ann Arbor, Michigan 4B109 Charles Bechhoefer Esq., Chaiman Atomic Safety & Licensing Board Panel U.S. Nuclear Regulatory Comission Washington, D.C.

20555 Mr. Glenn O. Bright Atomic Safety & Licensing Board Panel U.S. Nuclear Regulatory Commission Washington, D.C.

20555 NMg h@M.

_ WW -

9 aM eh e p Gg W,,, _ _

_W-h

.(.--

Zimmer Geosciences Branch 323.22 (2.5.2.5) 27 July 1980 Sharpsburg KY, Earthquake On 27 July 1980, a moderate earthquake occurred near the town of Sharpsburg, Kentucky atarc 42-45 miles SE of the Zimmer plant site.

Supply a complete report discussing all essential elements concerning this earthquake including:

1.

All magnitude estimates (Ms, MbLg, Mb,teleseismic) 2.

Epicentral Intensity and Isoseismal map 3.

Written description of felt effects and intensity at the plant site.

4.

Effect of the Ohio River valley on the intensity distribution of this event.

5.

All available references 323.23 Assuming the 27 July 1980 earthquake reoccurred in the immediate vicinity of the site, compare the estimated ground motion (Response spectra and peak) from this assumed earthquake to the SSE.

123.24 Since the Anna, Ohio earthqJake was considered to'be the basis for the SSE, both the 1937 Anna Ohio earthquake and the 27 July 1980 Sharpsburg, KY are spatially located near the Cincinnati Arch basement feature. Discuss these earthquakes in terms of their impact on your tectonic framework for the Central Stable Region and the Zimmer site area.

1