UNITED STATES NUCLEAR REGULATORY COMMISSION-0FFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.
20555 IE Bulletin No. 81-01 January 27, 1981 Page 1 of 7 SURVEILLANCE OF MECHANICAL SNUBBERS Description of Circumstances:
Several instances of failures of mechanical snubbers supplied by International Nuclear Safeguards Lorporation (INC) have been identified that indicate possible deficiencies in these snubbers.
A summary of the failures that have occurred is provided below:
-1.
On August 9, 1974, the Tennessee Valley Authority submitted event report BFAO-50-260/741W identifying 11 of 14 INC Model MSVA-1A snubbers that were found inoperable on Browns Ferry Nuclear Power Station Unit 2 and suosequently identifi N 5 of 14 inoperable units on Browns Ferry Nuclear Power Unit No 3.
All of these units were found to be frozen, and the cause was attributed to a failure to lubricate t'le parts during assembly.
The failed snubbers were replaced with new units produced by the same manufacturer.
2.
On April 12, 1976, the St. Lucie Plant Unit 1 facility of Florida Power and Light Company submitted event report No. 50-335-76-9 wherein five INC Model MSVA-1 snubbers were identified as inoperable because they were found to be frozen.
The failures were caused by oxidation on the internals and by improper assembly.
All INC mechanical snubbers were replaced with units produced by another manufacturer.
3.
On April 8, 1977, Iowa Electric Light and Power Ccmpany submitted event report No. 77-23 for the Ouane Arnold Energy Center facility that identi-fied 13 INC Model 1MSVA-1 Type AS snuocers to be frozen; tne cause of failure was attributed to large amounts of interior oxidation.
The units were replaced with those produced by another manufacturer.
4.
On Decemoer 5, 1979, personnel from the Nuclear Regulatory Commission visitec Deoar ment of Energy (00E) facilities at Ricnland, Wasnington, to cotsin information on 00E experience with INC snubbers at the Fast Flux Test Facility (FFTF).
The DOE-owned FFTF was equipped with more than 4,000 mechanical pipe restraints (snuobers) supplied by INC.
In 1978, FFTF examined mere than 800 oi these mechanical snubcers by removing them from their installation and fotnc that 43, or about 5% of those examinec, i
were frozen.
The olant was still under construction so the snuocers nad seen no service and had been subjected to only normal construction environments for 1 to 2 years.
8&l 44&a76
o -.
IEB'81-01 January 27, 1981 Page 2_of 7 Tests were' conducted on three operable snubbers by installing them on a
.Hanford Engineering and Development Laboratory (HEDL) process line.
The three snubbers were subjected to flow-induced low-amplitude vibration.
'(0.003 inches or less). These snubbers were of both the combined carbon steel and stainless steel construction and the all stainless steel con-struction.
Detailed test data are not available to the NRC at this time.
'However, all three snubbers froze after being subjected to the vibration -
for periods of 3 to 30 days.
The failure modes on all units inspected and tested involved a number of different mesnanisms ' leading to the freezir.g of i.he snubbers.
Followirg disassembly of some of caused by imprcper asse.the snubbers, inspections showed the failures were mnly; overheating of internal components caused by welding (during fabrication); and sensitivity of the design to. dirt, corrosion, and inadequate or excessive lubrication.
00E concluded that
' there were generic deficiencies in the design of the' snubbers of this specific manufacturer for application' to the FFTF facility and for pipes subjected to vibration.
All INC mechanical snubbers in FFTF have'been replaced with snubbers produced by another manufacturer.
5.
On May 31, 1980, Georgia Power Company reported eight INC snubbers located on instrument and drain lines at Edwin I. Hatch Nuclear Plant Unit 1 were identified as inoperable (LER 321-80-55).
The cause of the failures was identified as internal corrosion that caused a frozen condition.
In an attempt to free a snubber (750 pound capacity), forces up to 1500 pounds wer2 applied in both the " extend" and " retract" directions and the snubber did not move. The inspection of INC snubbers was completed at the Hatch facility and, on June 30, 1980, NRC received a supplemental report that r
45 of the 61 snubbers that had been inspected on Unit I had been identi-fied as inoperable and three of the 42 snubbers that were inspected on Unit 2 were inoperable. All inoperable snubbers were replaced prior to startup of the affected unit.
Some were replaced with mechanical units produced by another manufacturer, some were replaced with later-model INC i
snubbers, and three were replaced with rigid restraints.
Plans are being made to replace all INC snubbers during upcoming refueling outages.
Analyses are also being performed on the piping affected by the locked up snubbers.
In addition to INC snubber failures, failures of mechanic.al snubbers by another manufacturer are identified below:
~1.
On Septemoer 7, 1979, Puolic Service Electric and Gas Company reporteo the failure of three Model PSA-3 mechanical snubbers manufactured by Pacific Scientific Comoany that were located on a main feedwater line of Salem Nuclear Generating Station Unit 1 (LER 79-54).
These three snubbers could F
not be rotated around their spherical rod end bearings.
The snuobers were removed and inspection revealed that the lead scr w and traveling nut assemoly, wnien translates linear to rotational motion, had failed.
The snubbers no longer provided seismic shock restraint under this condition.
T
+
e e
,,, ~. ~ - -,
,e
--,-~m
,. w -- e,
-w,
-n,
-,-,-,-mm,,
,,,m,
-,w---e-,
c,
-gw
.o IEB 81-01 January 27, 1981 Page 3 of 7 These snubbers ar?. directly upstream of the nuclear Class II pi?f g boundary and are included in the stress calculations for the seismic analysis of the nuclear portion of the main feedwater piping.
Failure of the snubbers appeared to result from a force many times greatsr than the design load of the snubbers. This force was either an extreme shock load or occurrec when the snubber was in the fully retracted condition.
The snubbers were replaced with units produced by the same manufacturer.
2.
On April 10, 1979, Consumers Power Company reported a failure of eight r
Model-PSA-3 Pacific Scientific snubbers at their Big Rock Point Nuclear
' Plant facility (LER 79-017/03L-0).
The cause of the failure was improper s.
installation in that a spherical washer was omitted from the transition tube.
3.
On Maren 15 and June 11, 1979, Florida Power and Light Company reported failures of Pacific Scientific Company mechanical snubbers on main steam and feedwater systems at Turkey Point, Plant Units 3 anti 4 (LER 79-006/03L-0 and 79-009/03L-0, respectively).
The cause in both cases was attributed to excessive loading.
T'he nature of the above mechanical snubber failures is to p event the piping systems, to which they are attached, from moving freely during the normal thermal heat up and cool down associated with plant cperations.
Restraining this thermal motion results in higher than normal stresses which, if high enough and repeated frequently erough, can lead to a premature fatigue failure of the piping system.
These mechanical snubbers have been installed for,a number of years without any NRC requirements for periodic surveillance to determine their condition.
As a result, their current condition is unknowr to NRC and therefore NRC is requesting a prompt examination of all mechanical snubbers installed to date.
Because of the high percentage of failures discovered with the INC snubbers, the time frame for their examination is the shortest and additional opera-bility tests are called for.
t Actions to be Taken by Licensees of Ocerating Reactors:
1.
Within 30 days of the issuance date of this bulletin, all r.ornally accessible" INC mechanical snubbers installed on safety-related systems or.in storage shall be visually examined and tested as follows:
a.
Perform a visual examination for damage and, without causing the system to be inoperable except as permitted by the facility technical specifications, verify that the snubbers have freedom of movement by performing a manual test over the range of the stroke in both com-pression and tension.
f
""Normally access 1 Die" refers to those areas of the plant that can be entered during reactor operation.
c IEB 81-01 January 27, 1981 Page 4 of 7 b.
Perform an operability test to confirm that (1) activation (restraining action) occurs in both compression and tension, and (2) the drag forces are within the specified range in both compression and tension.
The tests shall be performed en all snubbers in storage
. and on a representative sample (10% of the total of this type of snubber in use in the plant or 35, which ever is less) of the normally accessible snubbers that are in service and can be indiv-idually removed without causing the system to be inoperable, except as permitted by the facility technical specifications.
For each snubber that does not meet the test acceptance criteria, an additional p
representative sample (as defined above) of this type of snubber shall-be tested.
For each of these additional snubbers that Jo not meet the
'l test acceptance criteria, another representative sample of this type of snubber shall be tested. This cycle shall be repeated until no more failures have been found or until all snubbers of this type have been tested.
The samples should be made up of snubbers representing the various sizes.
Snubbers which have been examined and tested in a manner comparable c.
to Items la a H lb above within the last six months may be exempted.
d.
If any failures are identified in Items la or Ib above, take corrective action and evaluate the effect of the failure on the system operability pursuant to the facility technical specifications for continued operation, If failures are identified in Items la and lb above, and if INC snubbers e.
are known to be located in any inaccessible areas, a p bnt shutJown shall be performed within 30 days after the discovery of the first inoperable snubber and inspections conducted in accordance with Item 2a and 2b below, unless justification for continued operation has been provided to the NRC.
2.
Visually examine and test all inaccessible INC mechanical snubbers installed on safety-related systems at the next outage of greater than five days duration as follows:
Visually examine and manually test all inaccessible snubbers as a.
described in Item la above.
b.
Perform an operability test on a represe..tative sample of inaccessible snubbers as described in Item lb above, Snubbers which have been examined and tested in a manner comoarable c.
to Items 2a and 2b above within the last six months may be exempted.
d.
If any failures are identified in Items 2a or 23 above, take corrective action to evaluate the effect of the failure on system coeraoility pursuant to the facility technical specifications for resuming ooeration.
a IEB 81-01_
January 27, 1981 Page 5 of 7 3.
Provide a schedule for an inspection program covering mechanical snubbers
. produced by other manufacturers. As a minimum, this inspection program shall:
Include all snubbers installed on safety-related systems; a.
b.
Include the visual examination and manual test described in Item la above for all snubbers;
_ Snubbers which have beer examined and tested in a manner comparable c.
to Item 3b above within the last twelve months may be exempted; d.
Regt;re the corrective action and evaluations described in Items ld and 2d above; and Be completed prior to the completian of the next refueling outage.
e.
Plants which are currently in a refueling outage should perform the visual examination and manual tests of inaccessible mechanical snubbers before resumption'of operations unless some other basis for assurance of snubber operability is provided to the NRC.
4.
Submit a report of tha results of the inspections, testing and evaluation requested in Item 1 to NRC within 45 days of the issuance date of this bulletin.
Report the results of the inspections, testing and evaluation requested in Itec 2 within 30 days after the inspection and testing have been completed.
The response to Item 3 shall be submitted within 60 days of the issuance date of this_ Bulletin.
The results of the inspections performed for ' tem 3 shall be submitted within 60 days after the comoletion of the inspection.
The reports shall contain the following:
A description of the visual examinatiens and tasts performed.
a.
b.
Number of snubbers examined and tested. Grouping by manufacturer name, model number, and size is acceptable.
Number of failures identified; manufacturer name, model number, size, c.
mode of failure, cause of failure, corrective action, snuober location.
effect af failure on plant and system safety, and justification for continuing or resuming operation, i
d.
The above information shall also be provided for the snubbers exempted by Items Ic, 2c, and 3t anove.
q m-4 IEB-81-01, Rev. 1 March 4, 1981
-Page 6 of 7 Actions to be Taken by the Following Licensees Holding Construction Permits:
Diablo Canyon Nuclear. Power Plant Units 1 and 2; Grand Gulf Nuclear Station,
~
R1 Unit 1; LaSalle County Station, Unit 1; Virgil C. Summer Nuclear Station, R1 Unit 1; and Susquehanna Steam Electric Station, Unit 1 shall perform the R1 following:
R1 1.
After preoperational and/or hot functional testing and preceding fuel loading, visually examine and test the mechanical snubbers installed on safety rela'ed systems as follows:
For all snubbers perform a visual examination for damsge and verify a.
that the snubbers have freedom of. movement by performing a' manual test over the range of the stroke in both compression and-tension.
b.
For INC snubbers, perform an operability test to confirm that (1) activation (restraining action) occurs in both compression and tension, and (2) the drag forces are within the specified range in both compression arid tension.
The tests shall be performed on a representative sample (10% of the total of this type of snubber in use in the plant or 35, whichever is less).
For each snubber that does not meet the test acceptance criteria, an additional representative sample (as defined above) of this type of snubber shall be tested.
For each of these additional snubbers that do not meet tne test acceptance criteria, another representative sample of this type of snubber shall be tested.
This cycle shall be repeated antil no more failures have been found or until all snubbers of this type have been tested.
The samples should be made up e.f snubbers that represent the various sizes.
If any failures are identified in Items a or b above, take corrective c.
action prior to fuel loading.
2.
The schedule for the inspections and tests requested in Item 1 above, shall be submitted within C0 days cf the issuance date of this bulletin.*
ihe R1 results of the inspections, testing, and evaluation requested in Item 1 shall be reported to NRC within 30 days after the inspection and testing nave been com;;?.sted.
The reports shall'contain the following:
A description of the visual examinations and tuts performed.
a.
l l
^The 'issanch date of this oulletin" shall be considered to be the date R1 of issuance of revision 1 for the following iicen=ees holding :onstruction R1
. permits; Diablo Canyon Nuclear Power Plant, Unit 2; Grand Guif Nuclear R1 Station, Unit 1; LaSalle County Station, Unit 1; and Susquehanna Steam R1 L
Electric Statien, Unit 1.
R1 l.
c:
?
._.__.__..,,...._...m.,,
L,
~
~
o IEB 81-01, Rev.1 March 4, 1981 Page 7 of 7 b..
Number of snubbers examined and tested.
Grouping by manufacturer name, model number, and si:e is acceptable.
Number of failures identified; manufact9rer name, model number, c.
size, mode of failure, cause of failure, corrective action, and snubber location.
Reports, signed under oath or affirmation, under the provisions of Section 182a of the Atomic Energy Act of 1954, shallsbe submitted to the Director of the appropriate NRC Regional Office and a copy shall be forwarded to the Director of the NRC Office of Inspection and Enforcement, Washington, D. C.
20555.
If you desire additional information regarding this matter, please contact the appropriate IE Regional Office.
Approved by GA0 B-180225 (581003) expires December 31, 1981.
I e
,.__._..,v.
,, _ -, _ _., _, _. _ _.. ~., - -...,
,,.,...,__,w.
., d a _.
M IE Bulletin No. 81-01,.Rev 1 March'4, 1981-RECENTLY-ISStlE0 IE BULLETINS Bulletin Subject Date. Issued Issued To
-~No.
. 80-21 Valve Yokes Supplied by
. 11/6/80-All light water Malcolm Foundry Company, Inc.
reactor facilities-holding noerating Licenses (OLs)-
or : onstruction Permits (cps) 80-22 A'utomation: Industries, 9/11/80 All radiography licensees-Model 200-520-008 Sealed-Source Connectors 80 Failures of Solenoid 11/14/80 All power reactor facilities Valves Manufactured by with Operating License (0L)-
Valcor Engineering or Construction Permit (CP)
Corporation 80-24 Prevention of Damage 11/21/80 All power reactor' facilities Due to Water Leakage with Operating License (0L)
Inside Containment.
or Construction Permit (CP)
(October 17, 1980 g
-Indian Point 2 Event)
Sup..4 Failure of Control Rods 12/18/80 To specified BWRs with Bulletin to Insert During A Scram an Operating License (OL) 80-17 at a BWR and All BWRs with a Construction Permit (CP) 80-25 Operating Problems with 12/19/80 All BWR facilities with Target Rock Safety-Relief Operating License (OL)
Valves at BWRs and specified near term Operating License (OL)