Responds to Re Request for Exemption from 10CFR50 App R,Item III.0 to Remove Requirement for Oil Collection Sys in Reactor Coolant Pump Bay & Item Iii.A to Drop Addl Fire Pump.Requirements Suspended Until Further NRC Action
ML19347E949
Person / Time
Site: La Crosse File:Dairyland Power Cooperative icon.png
Issue date: 05/06/1981
From: Harold Denton
Office of Nuclear Reactor Regulation
To: Linder F
DAIRYLAND POWER COOPERATIVE
References
LSO5-81-05-004, LSO5-81-5-4, NUDOCS 8105140396
Download: ML19347E949 (2)


Text

. A _.

pa raggjo UNITED STATES

+

g

,y g

NUCLEAR REGULATORY COMMISSION p

WASHINGTON. D. C. 20556 3 *-

0

%,,,. */

May 6, 1981 69 g

-t,[] f4 Docket No. 50-409 LS05-81 004

\\\\

9+

IAIN 1 g ggle

$q v.s.$5%,, $

Mr. Frank Linder General Manager Dairyland Power Cooperative 7

2615 East Avenue South 4

Lacrosse, Wisconsin 54601 to

Dear Mr. Linder:

By letter dated March 19, 1981, you requested an exemption to 10 CFR 50, Appendix R, Item 111.0 for,the Lacrosse Boiling Water Reactor (LACBWR).

This exegtion would remove the requirement for an oil collection system in the Reactor Coolann Pump (RCP) bay based on the substitution of a non-flammable fluid in the Forced Circulation Pump (Reactor Coolant Pump)

Coupling Oil System thereby reducing the quantity of flamable oil by about 90% to 15 gallons for each of the two pumps. Therefore, you assert that these measures would provide adequate fire protection.

You also requested an exemption to 10 CFR 50, Appendix R, Item III.A. This exemption would remove the requirement for an additional fire pump since you have already installed a new Emergency Service Water Supply System (ESWSS) and plan to upgrade the existing Fire Pugs by the addition of a sixth impeller stage to each pump. Therefore, you assert that the existing water supplies with modifications to the ESWSS meet the intent of Appendix R Item III.A and that another fire pump is not justified.

You should note that 10 CFR 50.48(c)(6) states that requests for exemptions from the requirements of Appendix R must assert either that the Appendix R require-ment would not enhance fire protection safety at the facility or that implementa-tion of the requirement would be detrimental to overall facility safety. Your letter does not explicitly make either assertion. We assume that you intend to rely on the first of these criteria, and will review your request on that basis.

If you also wish to rely on the second criterion, you should supplement your exemption request imediately.

On this basis we find that your requests provide sound technical basis warranting further staff review.

The schedule requirements for these items are, therefore, suspended in accordance with 10 CFR 50.48(c)(6) until final Commission action on these requests.

Sincerely, h$$

Harold R. Denton, Director Office of Nuclear Reactor Regulation l

i

.1 Mr. Frank Linder May 6, 1981 cc:

Fritz Schubert, Esquire Director Standards and Criteria Staff Attorney Division Dairyland Power Cooperative Office of Radiation Programs 2615 East Avenue South (ANR-460)

La Crosse, Wisconsin 54601 U. S. Environmental Protection Agency

0. S. Heistand, Jr., Esquire Washington, D. C.

20460 Morgan, Lewis & Bockius 1800 M Street, N. W.

Washington, D. C.

20036 U. S. Environmental Protection Agency Mr. R. E. Shimshak Federal Activities Branch La Crosse Boiling Water Reactor Region V Office Dairyland Power Cooperative ATTN: EIS COORDINATOR P. O. Box 135 230 South Dearborn Street Genoa, Wisconsin 54632 Chicago, Illinois 60604 Ms. Anne K. Morse Charles Bechhoefer, Esq., Chairman Coulee Region Energy Coalition Atomic Safety and Licensing Board P. O. Box 1583 U. S. Nuclear Regulatory Comission La Crosse, Wisconsin 54601 Washington, D. C.

20555 La Crosse Public Library Dr. George C. Anderson 800 Main Street Department of Oceanography La Crosse, Wisconsin 54601 University of Washington Seattle, Washington 98195 U. S. Nuclear Regulatory Comission Resident Inspectors Office Mr. Ralph S. Decker Rural Route #1, Box 225 Route 4, Box 1900 Genoa, Wisconsin 54632 Cambridge, Maryland 21613 Town Chairman Dr. Lawrence R. Quarles Town of Genoa Kendal at Longwood, Apt. 51 Route 1 Kenneth Square, Pennsylvania 19348 Genoa, Wisconsin 54632 Thomas S. Moore Chairman, Public Service Comission Atomic Safety and Licensing Appeal Board of Wisconsia U. S. Nuclear Regulatory Comission Hill Farms State Office Building Washington, D. C.

20555 Madison, Wisconsin 53702 Mr. John H. Buck Alan S. Rosenthal, Esq., Chairman Atomic Safety and Licensing Appeal Boarc Atomic Safety and Licensing Appeal Board U. S. Nuclear Regulatory Comission U. S. Nuclear Regulatory Comission Washington, D. C. 20555 Washington, D. C.

20555 U. S. Nuclear Regulatory Comission Mr. Frederick Milton Olsen, III Resident Inspectors Office 609 North lith Street Rural Route #1, Box 225 Lacrosse, Wisconsin Genoa, Wisconsin 54632