ML19347E220

From kanterella
Jump to navigation Jump to search
Forwards Monthly Status Rept for Apr 1981 Re IE Bulletin 79-14, Seismic Analysis for As-Built Safety-Related Piping Sys
ML19347E220
Person / Time
Site: Browns Ferry  Tennessee Valley Authority icon.png
Issue date: 04/10/1981
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
IEB-79-14, NUDOCS 8104240275
Download: ML19347E220 (31)


Text

4 e

400 Chestnut Street Tower II

. April 10, 1981 Mr. James P. O'Reilly, Director Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission f

j Region II - Suite 3100

{6. 7 "4

8?

i 6/gA 'I 101 Marietta Street

~

Atlanta, Georgia 30303

%D

Dear Mr. O'Reilly:

/

Y CE OF INSPECTION AND ENFORCMENT BULLETIN 79 RII:JP

@ @ BROWNS FERRY NUCLEAR PLANT

-2 Enclosed is the monthly status report for work related to IE Bulletin 79-14 being performed at the Browns Ferry Nuclear Plant. This report presents the status of work as of April 1, 1981.

If you have any questions please get in touch with Jim Domer at FTS 857-2014.

To the best of my knowledge, I declare the statements contained herein are complete and true.

Very truly yours, TENNESSEE VALLEY AUTHORITY

/.. ;.

L. M. Mills, Manager Nuclear Regulation and Safety Enclosure l

l l

l g

l l

l l

8104240275

o s

BROWNS FERRY NUCLEAR PLMfr IE BULLETIN 79-14 PROGRESS REPORT APRIL 1981 SECTION A REPRESENTS OVCRALL PERCENTAGE COMPLETION OF 79-14 AT BROWNS FERRY SECTION B REPRESENTS DRAWING CONFIGURATION INSPECTION SECTION C REPRESENTS PIPE SUPPORT INSPECTION 1ECTION D REPRESENTS FLOOR AND WALL PENETRATION INSPECTION SECTION E REPRESENTS VALVE INSPECTION l

{

{

8 m

o c'

Al OVI'.1:Al.i. I'F.!(CE.:TAGE UNIT 1 ITNIT 1 UNIT 2 UNIT 2 CNIT 3 (0:IT 3 SYSTDI ACCESSIBLE INACCESSIBLE ACCESS IBLE INACCESSIBLE ACCESSILLE INACCESSIBLE Cors Spray 100%

100%

0%

100%

100%

100%

CitD 100%

100%

75%

100%

100%

100%

CSS 100%

NA 0%

NA 100%

NA Ring Hender DW & Torus 100%

NA 0%

NA 100%

NA Purge Piping Drywell NA 100%

NA 100%

NA 100%

Spray Hrader

~

Torus NA 100%

NA 100%

NA 100%

Spray llender Drywell NA 100%

NA 100%

NA 100%

l Control Air EECW 95%

NA 30%

NA 40%

NA Fe:dwater NA 100%

NA 100%

NA 100%

FPC 100%

100%

0%

100%

100%

100%

~

.Q.,e

.-s a <

wr.

=

e.

  • .--.s-

.m--_.

~

S e'

A2 OVERALL l'ERCENTAGE UNIT 1 UNIT 1 UNIT 2 C:IT 2 r:IT 3

7. !T 1

)

SYSTDI ACCESSIBLE INACCESSIBLE ACCESSI LE INACCESSIBLE ACCESSILLE !'.!ACC SSISLE

!!PC1 100%

1007.

o.:

100%

3 5l'.

'N 7. -

Main NA 100%

!L\\

100%

NA 100%

Stcam Torus 100%

NA 100%

NA 100*

A Ring H:ader RBCcti 100%

100%

30%

100%

100%

100%

RCIC 100%

100%

85".

100%

85%

100".

Recircu-NA

..J%

NA 1007.

NA 100%

lation l

Ri!R 100%

100%

15%

100%

50%

100%

RilRS11 95%

NA 5%

NA 95%

NA i

I Rt!CU NA 1007.

NA 100%

NA 100" j

l l

Radwaste 100%

100%

60%

1007.

100%

100%

Sump Ptimp l

Dischar;;c pg 6f g & p a

1-

.---.d.-

...--.m,___--.

=xa m:-,_

. ~, -,

t

. '. 3 (WERALL PERCE::TAGE liNIT I U: IT 1 U;IIT 2 ti::IT 2 1:::IT

  • IJ::IT 3 SYSTDI ACCESSIBLE 13/<CESSIBLE ACCESSLCLE (MACCESSILLE ACCESS;;LE 1:: ACCESSIBLE Its Drain NA L00%
A 100%
A 100%

& Vent SGT 100%

NA 100%-

NA 100';

A SLC 100%

100%'

0%

100%

1000 100%

W i

4 1

me ear,'a,

.. 6...e.% [.. ~

  • m r=[ e ---.,2 g m m _ a, _ _ g.

g y.,__.

_ _,. - ~. _ -. - _.

?

8 i

1 -

i DR4 WING CONFICURATION INSPECTION 7

NimBER.

NtRIBER UNIT SYSTEM INSPECTED WITH 31G 'IFIC.u;T r.!BER TO DATE DEVIATIONS DEVIATIONS

/IPAIRED 1

Core Spray 3

0 0

0 4

t 2

0 0

'O 2

Core Spray _

1 J

3 Core Spray 8

3 0

2 1

1 CRD 3

1 2

0 I

2 CRD 8

3 1

0 l

l l

a 3

CRD 7

4 1

0 0

1 CSS Ring Header 1

1 0

0 l

i 2

CSS Ring. lieader 1

1 0

0 I

i 3

CSS Ring IIeader 1

1 0

0 i

i 1

DW and Torus 4

4 0

0 Purgo Piping 2

DW and Torus 0

0 0

0 Purgo Piping

)

3 DW and Torus 1

1 0

0 Purge Piping a /W8. *

- 2

.m=.:.z m -r--,eara ua rm..=m

.. ~..

. _........,_._.., _. _ _ _...._,. _, -.._ _ __ ~ _.

e 02 DELWING CONFICURATION I::SPECTION

':UllBER MittBER UNIT SYSTD1 1;;SPECTCD 11 I 1 11 S IG::IF LC/J.~f

0!BER TO DATE DEVIATIO::S DE'.* f ATIO:!S REPAI*tED 1

Dryvell Spray 4

1 0

0 Header 2

Dryuell Spray 1

0 0

0 Header 3

Drywell Spray 1

0 0

0 Header 1

1 Torus Spray 1

1 0

0 Header 2

Torus Spray 1

0 0

0 Header 3

Torus Spray 1

1 0

0 1

Header 1

Drywell 1

0 0

0 Control Air 2

Drywell 1

1 0

0 Control Air 3

Drywell 4

0 0

0

~

Coctrol Air 1

EECW 17 14 2

0 2

EECW 0

0 0

0 3

EECW 8

5 1

0 ne m

'yI

'e V

4

+.. z.r aw. w =_m.-=r r.ar.a.2..s.._ r.tx t_:ar- -- -

1)RAtlI:3; CONFICURATION IMSPECTIOil "J

U>tBER MDIBER UNIT SYSTD1 INSPECTED WIT 11 SIG::IFIC.\\:iT
E!BER TO DATE 1)EVIATIOMS DEVIATIOMS E?AIPED 1

Feedwater 1

0 0

0 2

Feedwater 1

0 0

0 3

Feedwater 1

0 0

0 1

FPC 4

2 0

0 2

FPC 2

0 0

0 3

FPC 2

2 0

0 t

itPCI 4

2 0

0 2

ilPCI 3

2 0

0 3

IIPCI 2

1 0

0 l

l l

1 5tain Steam 3

1 0

0 2

Sta in S t eam 2

L 0

0 3

Stain Steam 3

2 0

0 r %...,~. y e- @:*,

4

-- - -.m a _...,,... _,. ___

__..._<f"-

DRAUING CONFICURATION I:SPECTION

iU11BER
C13ER UNIT 3YSTCt I:ISPECTED WITil SIG'IFICA:;T
C!BC!!

TO DATE DEVIAT[0 :S DEVI ATIO:IS

!!EPAIRCD 1

Torus Ring Header 1.

1 0

0 2

Torus Ring Header 1

0 0

0 3

Torus Ring Header 1

1 0

0 1

RSCct 11 5

13 13 2

RBCCW 3

1 0

1 3

RSCCI 7

2 3

0 4

3 0

0 1

RCIC 2

RCIC 4

4 0

0 3

RCIC 7

5 0

0 i

l l

1 Recirculation 1

0 0

0 1

2 necirculation 2

1 0

0 i

3 Recirculation 3

0 0

0 e

an.

~ -

e" I e <

'm..

M* M

  • 3 3 M Mg',*,,-- -* --- * *
  • a

, yg ae.=

0 DR.\\WI::G CONFIC!,!RXilON INSl'ECr(0:4

1?tBE!
1,7tBER SIG::IFICJdir

..::3ER UITil UNIT SYSTEM I::SPECTED DEVINCIO::S

.I??,I2ED TO DATE DEVIXEIO;;S 1

0 13 13 L

RHR 0

0 1

0 2

RHR 0

0 6

12 3

RHR 1

1 0

1 1

RHRSU 0

1 0

C 2

RHRSU 0

0 1

1 3

RHRSU 0

0 0

2 1

RUCU 0

0 1

2 2

RWCU 0

0 1

2 3

RUCU l

10 0

2 2

1 Radwaste Sump l' ump Discharge 4

1 0

4 2

Radwaste Sump Pump DLscharge 1

0 1

1 3

Radwaste Sump Pump Discharge e,,,,A

~

s

,p' d---=-

~

.w.kW~l K s.u.::.~..s ;_5-_:

'CT:LL*~=.~;

~

1 a

als ORx!U:s: CONY LI:l:RATlott l:::il*CCr LU.t NQtBER

EISER UNIT SYSTCt INSPECTED WIIll SIG:;IFICl.::T
QtBER TO DATE DEVIATIONS DEVIAT NSS i
EPAIT,E3 1

RX Drain and 1

1 0

.0 i

Vent 2

RX Drain and 2

2 0

0 Vent 3

RX Drain and 2

1 0

0 Vent 1

SGT 1

1 0

1 2

SGT 1

0 1

1 3

SGT 1

1 0

0 l

1 SLC 3

3 0

0 l

2 SLC 1

1 0-0 b

l 3

SLC 4

0 0

i l

l

{

i

==e

  • -**g 94*y ah.

~..- -- m v - -- ~~e-

~

--n= -a:t.w:.ws.v:

's.

m

..,--m.

-,_._,,x-,

,,._....,_.,,_,,.-.-r.~

1:1 PIPE SUPPollT I:1SPECTIO:1

lD!BER
D!l5EI' U!i1T SYSTDI I!!SPECTED

'JIT11 31G::IFICA:T

"L'.!BER TO DATE DEVIATf 0
:S DEVTATIq::S

'!? AIRED 1

Core Spray 92 38 0

L6 2

Core Spray 16 5

0 4

3 Core Spray 106 64 0

1 1

CRD 89 24 0

3 2

CRD 107 16 0

0 83 17 0

0 3

CRD 1

CSS Ring Header 29 7

0 3

2 CSS Ring Header 0

0 0

0 3

CSS Ring Header 32 32 5

0 i

1 Dti and Torus 31 0

0 5

Purge Piping 2

011 and Torus 0

0 0

0

(

Purge Piping t

3 Ott and Torus 27 0

0 0

Purge Piping m

.....e.

_s nA='

Y

  • ' s n.

r-A f e,*

Cl PIPE SUPPORT I::SPECT[0:I NU:fBER

ElBER UNIT SYSTC!

INSPECTED WITll SIG :IFIC/C:T lr.!BER TO DATE DEVIATIO.S DEVIATIC::S REPAIRED 1

Drywell Spray 12 0

0 0

Header 4

2 Drywell Spray 8

0 0

0 Header 3

Drywell Spray 16 0

.0 0

Header 1

1 0

0 1

Torus Spray Header 2

Torus Spray 16 16 0

0 Header 3

Torus Spray 16 16 0

0 Header 4

2 0

0 1

Drywel Control Air 3

3 0

1 l

2 Drywell Control Air 3

Drywell 19 3

0 0

f Control Air 1

EECW 269 61 2

13 2

EECW 18 10 0

2 3

EECW 159 70 1

2 t

Jby,,5 '.*

  • p, e*

m

~

.T!.*.*.~ ~

%<MM~M%.;y,,wy;my.

,._-gg,..

~ ~ ~ "

  • C3 PIPE SUPPORT I:!SPECTION NID!BER I't;;tBr.t:

UNIT SYSTDI INSPECTED WIT!!

SIG::LFICA:;T

~;CtBER TO DATE DEVL\\TIONS DEVIATIO:is

-EPAIRED 1

Feedwater 28 9

0 0

2 Feedwater 40 13 0

0 3

Feedwater 36 24 0

8 1

FPC 134 4S 0

9 2

FPC 7

0 0

0 107 60 1

1 3

FPC 88 SS 2

24 1

IIPCI 2

HPCI 25 23 0

3 3

HPCI 82 27 2

3 85 8

0 0

1 Main Steam 2

Main Steam 118 24 0

3 3

Main Steam 115 15 0

1 4

'8 m

'T l'

49 M

,' T="a * *

. _w*s=r -._-:rsa ?

r.Jer._. a:=-

n m

':4 P[PE SUPPORT I::SPECTf 0N NUtBER

U:1BER U:!IT SYSTDI INSPECfED

!!ITil SIG::IFICA:T

':'C.1B ER TO DATE DEVIATIO!S DEVIATIO!:S REPAIRED 1

Torus Ring Header 23 4

0 0

2 Torus Ring Header 24 8

0 0

3 Torus Ring Header 30 30 0

0 1

RBCCJ 17 6 153 2

77 2

RBCC;J 81 76 0

1 3

RBCCJ 184 158 2

14 1

RCIC 57 38 1

11 2

RCIC 64 37 0

8 3

RCIC 65 30 0

5 1

RCtf 5

5 0

2 2

RCJ 2

2 0

2 3

RCi 1

1 0

1 GD W

  • ~ ~ ~

?.

9

C3 PIPE SUPPORT INSPECTION

UMBER
UllBER UNIT SYSTE!!

INSPECTED WITH SIG::IFICA::T

I~.ICER TO DATE DEVIATIONS DEVIATIONS
.E? AIRED 1

Recirculation 47 3

0 0

2 Recirculation 39 38 1

3 3

Recirculation 61 35 0

0 1

RHR 296 220 4

63 2

RHR 36 15 1

2 3

RHR 178 35 3

15 1

RHRSW 50 36 6

17 2

RHRSW 11 6

2 3

3 RHRSW 15 9

0 1

1 RUCU 15 4

0 1

2 RWCU 7

7 0

1 3

RUCU 14 4

0 1

~

-,,4 {,"

..c

~

- - - - ~ ~ - - - ~ -

==

' ; s:L N.~0 T.@h.4..,,ga t ;=s a - -- -,.

-" ' ~ ~ *

  • d5
  • PIPE SUPPORT I:SPECTION

!U:1BER lMIBER UNIT SYSTDI INSPECTED WITH SIC'.!IFICA::T

E:3ER TO DATE DEVIATIO::S DEVIATIO:iS itEPAIRED 1

Recirculation 47 3

0 0

2 Recirculation 39 38 1

3 3

Recirculation 61 35 0

0 1

RRR 296 220 4

63 2

RHR 36 15 1

2 3

RHR 178 35 3

15 1

RHRSW 50 36 6

17 2

R11RSW 11 6

2 3

s 3

RHRSU 15 9

0 1

1 RWCU 15 4

0 1

l l

2 RWCU 7

7 0

1 l

3 RUCU 14 4

0 1

l l

.e

- nw..

m....,

-. a m._ _

_ _ _.. a; g. _. ; __

':6 O

PIPE SUPP01tT INSPECTION NLRIBER

U:tBER UNIT SYSTEdi INSPECTED WITIl SIG:IFICANT

':O'BER TO DATE DE'fIKrIONS DEVIATIO :S

.EPAI:tED 65 12 1

8 1

Radwaste Sump Pump Discharge 62 2

1 0

2 Radwaste Sump Pump Discharge 73 60 0

1 3

Radwaste Sump Pump Discharge 17 11 1

0 L

RX Drain and Vent 20 15 1

3 2

P.X Drain and Vent 21 18 0

0 3

RX Drain and Vent 24 5

0 12 1

SGT 19 6

0 0

2 SCT 13 5

0 0

3 SGT 60 18 0

0 1

SLC 16 2

0 1

2 SLC 76 24 0

6 3

SLC O

6

--n---

-.-=~-_

. w~~~w

.num 9

~ - * -

I i

DI FLOOR AND t/ALL PENETRATION I::SPECTION NID!BER NUMBER UNIT SYSTDI INSPECTED

!!IT11 SIG::IFICA!;T lr.!BER TO DATE DEVIATIONS DEVIATIO::S REPAIRED 1

Core Spray 15 0

0.

0 2

Core Spray 1

0 0

0 3

Core Spray 3

1 0

1 1

CRii 1

0 0

0 4

2 CRD 4

0 0

0 3

CRD 2

0 0

0 l

1 CSS Ring liender 0

0 0

0 2

CSS Ring IIeader 0

0 0

0 t

3 CSS Ring Header 1

0 0

0 l

)

1 Dti and Torus 3

0 0

0 Purge Piping i

2 011 and Torus 0

0 0

0 Purge P Lping

+

3 011 and Torus 3

0 0

0 Purge Piping i

=+

a--,-.

6..., -

l

.a_..

_.wa

-a _

--- ~.-,-_,

FLOOR AND IJALL PENETRATION INSPECTIO:;

NIDIBER

.: UMBER UHIT SYSTDI INSPECTED WIT 11 3[C:!IFICA :T

"' 3CP TO DATE DEVIATIONS DEVIATIONS

'. P.'. IRED 1

Drywell Spray 0

0 0

0 Header 2

Drywell Spray 0

0 0

0 Header 2

0 0

0 3

Drywell Spray Header 0

0 0

0 1

Torus Spray Header 0

0 0

0 2

Torus Spray Header 0

0 0

0 3

Torus Spray Header 1

0 0

0 1

Drywell Control Air 2

0 0

0 2

Drywell Control Air 2

1 0

0 3

Drywell Control Air 17 0

0 0

1 EECil 0

0 0

0 2

EECW 3

EECil 5

0 0

0 n pp.,

y ::-g c-

~

-wa.

n.

-w

.-.-.----m.

~_

-c-

~-- - - - - - -

e

01 F(40lt AND WAl.t. P!2iETRATIO*! 1 :SPl?Cr f u.';

NUMBER

E!BER UNIT SYSTEM INSPECTED WITH SIG
!IFICA'T 2r!BER TO DATE DEVIATIONS DDlIATIONS itEPAIRED 1

Feedwater 0

0 0

0 9

i 2

Feedwater 1

0 0

0 3

Feedwater 2

0 0

~2 i

1 FPC 0

0 0

0 2

FPC 3

0 0

0 3

FPC 2

2 0

0 1

HPCI 13 3

0 0

3 2

HPCI 1

0

-0 0

l l

3 0

0 0

3 HPCI l

l 1

!!ain Ste.,m 0

0 0

0 I.

2 Main Steam 2

0 0

0 i

3 Mair. Steam 3

0 0

0 l

,.,+ '

.p, n,

l Ew

, w--

- - - - - - + _ _,, _ _ _

L ____

-=~~4

D' FLOOR AND WALL PENETRATION INSPECTION NUMELR

L71BC*1 UNIT SYSTDI INSPECTED WITil SIC::IFICANT
7CIBER TO DATE DEVIATIONS DEVIATIONS

?.I? AIRED 1

Torus Ring Header 0

0 0

0 2

Torus Ring Header 0

0 0

0 3

Torus Ring Hender 0

0 0

0 1

RBCCW 5

0 0

0 2

RBCCW 2

0 0

0 3

RBCCW 7

2 0

0 1

RCIC 11 0

0 0

2 RCIC 12 0

0 0

3 RCIC 13 0

0 0

l 1

Recirculation 1

0 0

0 l

I

(

2 Recirculation 1

0 0

0 l

3 Recirculation 12 0

0 0

l

_ _,./

, ' 35'k;M;4*:$

~~

t w-r._.....


m

rd FLOOR A :D t/ALL PE! ETRATIO~;I I::SPECTIO:-I NU.!BER

~U:tBER UNIT SYSTDI IN WECTED WITil SIC::IFICANT.
ElBER Ti' 9 ATE DEVIATIO::S DEVIATIO:IS REPAIRED 7

2 0

0 1

RHR 2

RHR 1

0 0

0 1

0 0

0 3

RHR 1

RilRSW 3

0 0

0 2

RHRSW 0

0 0

0 3

RHRSW 0

0 0

0 1

Rt/CU 1

0 0

0 2

RtiCU 1

0 0

0 3

Ri/CU 2

0 0

0 1

Radwaste Sump 2

0 0

0 Pump Discliarge 2

Radwaste Sump 2

1 0

0 Pump 01scliar;;e 3

Radwaste Sump 2

0 0

0 Pump Discharge 66

__- n.,--

- *~ a

~

as_

i. zen---

06 FLOOR.CD WALL PE:!ETRATION INSPECTIOU e

NIDIBER

CIBER UNIT SYSTDI INSPECTED WIT 11 SI(:::IFICANT
".1!3ER TO DATE DEVIATIONS DEVIATIONS
'T.? AIRED 1

RX Drain and 0

0 0

0 Vent 2

RX Drain and 0

0 0

0 Vent 3

RX Drain and 1

0 0

0 Vent o

-o 0

0 1

SGT 0

0 0

0 1

l 2

SGT 0

0 0

0 3

SGT l

1 0

0 0

1 SLC 0

0 0

0 2

SLC 11 0

0 0

3 SLC f

i e

- //

G-@&)ir..; - -,.-4l",

l m

~.

..... a._

s..w

.n.n _.n.

dl e

VALVE I::SPECTION NU:tBER

tallW.R UNIT STSTC1

[NSPECTED WITil 3iC::Il*Ica:: r NU)!BER TO DATE DEVIATIO::S UtVIATIO :S i:EPAIRED 1

Core Spray 63 1

0 0

4 0

0 0

2 Core Spray 3

Core Spray 82 0

0 0

1 CRD 5

0 0

0 2

CRD 30 0

0 0

3

,CRD 17 0

0 0

1 CSS Ring liender 0

0 0

0 l

l 2

CSS Rin;; IIcader 0

0 0

0 i

i 3

CSS Ring Header 0

0 0

0 I

1 DW and Torus 9

0 0

0 Purge Piping i

I 2

DW and Torus 0

0 0

0 Purgc Piping l

I l

3 DW and Torus 7

0 0

0 l

Purge Piping a..... :

l

.-.-+,.-.,.-_-==a_s_-______

. - - ~,. _ _, _ _ - - _ - -.. -

E2 VALVE INSPECTION NID1BER

IniBER

~

UNIT SYSTD1 INSPECTED WIT 11 SIC:lIFICANT

..T3ER TO DATE DEVIATIO::S DEVIATIO;;S 3E? AIRED 0

0 0

0 1

Drywell Spray Header 0

0 0

0 2

Drywell Spray Header 0

0 0

0 3

Drywell Spray Header 0

0 0

0 1

Torus Spray Header 0

0 0

0 2

Torus Spray Header 0

0 0

0 3

Torus Spray Header 5

0 0

0 1

Drywell Control Air 5

0 0

0 2

Drywell Control Air 8

3 0

0 3

Drywell Control Air 1

EECW E06 4

2 0

2 EECW 2

L 0

0 71 2

0 0

3 EECJ y 7-+ >.

- ;g,._,,...,

.g.,,

_:===:m-a. 2u_

-_-g r=.,.,,

VALVE 1::SPECTION 0

4

..CIBER

U'IBER UNIT SYSTE!

I:!SPECTED ti1Til SIG:;IFIC.u.i E.GER TO DATC DEVIATIO:iS DE'.*IAT 3::S REPAIRED 1

Fe edwater 8

0 0

0 2

Feedwater 6

0 0

0 3

Feedwater 6

0 0

0 I

1 FPC 40 0

0 0

2 FPC 2

0 0

0 3

FPC 41 0

0 0

1 HPCI 21 2

0 0

2 IIPCI 5

0 0

0 3

HPCI 21 0

0 0

1

!!ain Steam 8

0 0

0 2

!!ain Steam 34 1

0 0

l 3

!!ain Steam 36 0

0 0

l p6

e.

E '.

o-VA'LVE I::SPECTION l;U5!BER

Ul!BER UNIT SYSIE:t INSPECTED UITH SIC::IFICA!Tr

'.I:4BEP.

TO DATE DEVIATIONS DEVIATIONS

2? AIRED 0

0 0

0 1

Torus Ring Header 0-0 0

0 2

Torus Ring Header 0

0 0

0.

3 Torus Ring Header 61 1

0 0

L RBCCW 23 0

0 0

2 RBCCW 49 2

0 0

3 RBCCJ 18 0

0 0

1 RCIC 21 1

0 0

2 RCIC 1

0 0

30 3

RCIC 6

0 0

0 1

Recirculation 0

0 0

14 2

Rec ircula tion 6

0 0

0 3

Recirculation g.#.. _,,_..

.am__

--...A

C3 V.1LVE INSPECTIO:1 NIR!BER NCISER UNIT SYSTCt INSPECTED tlITil SIC::IFICA::T

CIBER TO DATE DEVIATIONS DE*.'IATIO::S

?.EPAIRED 1

RRR 108 3

0 0

2 RER 23 4

0 0

3 RHR 93 6

0 0

1 RHRSW 12 0

0 0

2 RliRSU 11 0

0 0

3 RHRSW 0

0 0

0 1

RWCU 6

0 0

0 2

RWCU 5

0 0

0 3

RUCU S

0 0

0 1

Radwaste Sump 47 0

0 0

Pump Discharge 2

Radwasto Sump 45 0

0 0

Pump Disciurge 3

Radwaste Sump 39 4

0 0

l Pump Discharge l

l

~

l

~

,t.>>

.~.-r~,.

3 ny e

e.

j o

a:6 VALVE I::SPECTION CIBER

UtnElt UNIT SYSTEM INSPECTED

'.1ITil SIG:;Ll'IC.i:?T

'CISER TO DATE DEVIATIONS D E','IATICNS

'I?.iIRED 1

RX Drain and 8

0 0

0 Vent 2

RX Drain and 9

0 0

0 Vent 3

RX Drain and 8

0 0

0 Vent 0

0 0

0 1

SGT 2

0 0

0 2

SGT 2

0 0

0 3

SGT 47 0

0 0

1 SLC 4

0 0

0 2

SLC l

45 0

0 0

3 SLC l

y m....

m Z,.. ;TT,

./

ers w.

..u.._,.___

-