ML19347D320
| ML19347D320 | |
| Person / Time | |
|---|---|
| Site: | Hatch, Vogtle |
| Issue date: | 03/04/1981 |
| From: | James O'Reilly NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| To: | John Miller GEORGIA POWER CO. |
| References | |
| NUDOCS 8103170079 | |
| Download: ML19347D320 (1) | |
Text
-
g>C Uhq t
UNITED STATES 8
~'g 8 ' ',, 7 j
NUCLEAR REGULATORY COMMISSION c
REGION 11 g-a#
e 101 MARIETTA ST., N.W., SUITE 3100 ATLANTA, GEORGIA 30303 MAR 4 1981 In Reply Refer To:
RII:JP0 50-321 50-366 j;TQD 50 423 3
. ?,
2 c5E324 Y
W Georgia Power Company
. ag O s 7gg 3
L ATTN:
J. H. Miller, Jr.
'6 v,
a Executive Vice President 270 Peachtree Street 1
Atlanta, GA 30303 9
Gentlemen:
IE Bulletin 81-01 has been revised to change the identification of the power reactor facilities with construction permits to which the bulletin is applicable.
This change does not affect your requirements with respect to the bulletin. As a result, the enclosed revised pages 5 and 6 are forwarded to you for information.
Should you have any questions regarding this bulletin revision, please contact this office.
Sincerely, James P. O'Reilly Director
Enclosures:
1.
IE Bulletin No. 81-01 witn revised pages 5 and 6 2.
List of Recently Issued IE Bulletins cc w/ encl:
M. Manry, Plant Manager C. E. Belflower, Site QA Supervisor W. A. Widner, Vice President and General Manager-Nuclear Generation K. M. Gillespie, Construction Project Manager E. D. Grsover, QA Site Supervisor l
D. E. Dutton, Project General Manager
)
810317 0 Og
SSINS No.:
6820 Accession No.:
8005050075 IEB 81-01 UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.
20555 January 27, 1981 IE Bulletin No. 81-01:
SURVEILLANCE OF MECHANICAL SNUESERS Description of Circumstances:
Several instances of failures of mechanical snubbers supplied by International Nuclear Safe. guards Corporation (INC) have been identified that indicate possible deficienc@sinthesesnubbers. A summary of the failures that have occurred is provided below:
1.
On August 9, 1974, the Tennessee Valley Authority submitted event report BFAO-50-260/741W identifying 11 of 14 INC Model MSVA-1A snubbers that were found inoperable on Browns Ferry Nuclear Power Station Unit 2 and subsequently identified 5 of 14 inoperable units ca Browns Ferry Nuclear Power Unit No 3.
All of these units were found to be frozen, and the cause was attributed to a failure to lubricate the parts during assembly.
The failed snubbers were replaced with new units produced by the same manufacturer.
2.
On April 12, 1976, the St. Lucie Plant Unit I facility of Florida Power and Light Corporation submitted event report No. 50-335-76-9 wherein five INC Model MSVA-1 snubbers were identified as inoperable because they were found to be frozen. The failures were caused by oxidation on the internals
.and by.ifnproper.as.sembly. All.INC. mechan.ical snubbers were replaced with units produced by 'ano'ther manufacturer.
3.
On April 8,1977, Iowa Electric Light and Power Company submitted event report No. 77-23 for tne Duane Arnold Energy Center facility that identi-fied 13 INC Model IMSVA-1 Type AS snubbers to be frozen; the cause of failure was attributed to large amounts of interior oxidation.
The units were replaced with those produced by another manufacturer.
l 4.
On December 5,1979, personnel from the Nuclear Regulatory Commission visited Department of Energy (DOE) facilities at Richland, Washington, to obtain information on DOE experience with INC snubbers at the Fast Flux Test Facility (FFTF). The DOE-owned FFTF was equipped with more than 4,000 mechanical pipe restraints (snubbers) supplied by INC.
In 1978, FFTF examined more than 800 from their installation and M*
DUPLICATE DOCUMENT were frozen. The plant was l
seen no service and had bee 1
Entire document previously l
environments for 1 to 2 yea entered into system under:
8005050075 nuo sueb b bulietins No. of pages:
[
~
mwm na