ML19347C668

From kanterella
Jump to navigation Jump to search
Forwards Anl Rept, Failure Analysis of Cracked Core Spray Piping from Quad Cities Unit 2 Bwr
ML19347C668
Person / Time
Site: Quad Cities 
Issue date: 12/29/1980
From: Janecek R
COMMONWEALTH EDISON CO.
To: Ippolito T
Office of Nuclear Reactor Regulation
Shared Package
ML19347C669 List:
References
9261A, NUDOCS 8101050066
Download: ML19347C668 (1)


Text

-

Commonwealth EdisoA

'9 ono >,rst Nat on;11 Plan ' Chicago limior,

=9 g's/ ' [^ Address Reply to-Post Olhce Box 7G7 t;,_

c *:

MChrcago. m>noe 60690

.s

< n g) t.

N a

h'-~

~j:

De cembe r 29, 1980 Mr.

T.

A.

Ippolito, Chief Operating Reactors - Branch 2 Division of Operating Reactors U.S. Nu clear Regulatory Commission l

nashington, DC 20555

(

Subj e ct :

Quad Cities Station Unit 2 Core Spray Piping Failure Analysis NRC Do cke t No. 50-265 l

Dear Mr. Ippolito:

Encloseu for your use is the report, "Falure Analysis of Cracked Core Spray Piping from the Quad Cities Unit 2 Uoiling Waler Rea cto r. "

Also enclosed is a page identifying and corre ct in0 an error on page 23 of the report.

One (1) signed original and thirty-nine (39) copies of this transmittal letter and five (5) copies o f this report are provided for your use.

Very truly yours, lc,-

.>..<s' f Robert F.

Ja ne ce k

/, Nu clea r Li cens ing Adminis t rato r Boiling Water Heactors E n clo su r e s cc:

RIII Inspector, Quad Cities 9261A o c) s l/

8]O1050 % C:>

h

-