ML19347C650
| ML19347C650 | |
| Person / Time | |
|---|---|
| Site: | Marble Hill |
| Issue date: | 12/18/1980 |
| From: | Shields S PSI ENERGY, INC. A/K/A PUBLIC SERVICE CO. OF INDIANA |
| To: | Eisenhut D Office of Nuclear Reactor Regulation |
| References | |
| 1219804025, NUDOCS 8101050015 | |
| Download: ML19347C650 (4) | |
Text
1219804025 y
PUBLIC a
SERVICE i
T:
=
o O
S. W. Shields Sernor Vice Prescent -
December 18, 1980 Nuclear Division Mr. Darrell G. Eisenhut, Director Docket Nos.-
STN 50-546 Division of Licensing STN 50-547 Office of Nuclear Reactor Regulation Construction Pernit Nos. :
U. S. Nuclear Regulatory Commission CPPR - 170 Washington, D. C.
20555 CPPR - 171 Marble Hill Nuclear Generating Station - Units 1 and 2
Dear Mr. Eisenhut:
Please reference my October 31, 1980, letter in response to your request that Public Service Company of Indiana, Inc. (PSI) voluntarily submit information relative to the environmental qualification tests to be conducted within the next two years on safety-related equipment. Due to the large volume of infomation to be processed and the latc date at which PSI received the letter, it was not possible to respond by November 1, 1980.
During the intervening time PSI has contacted the architect-engineer and various vendors requesting information on environmental qualification of safety-related equipment. Attached is a list that PSI has compiled by using the information currently available to us.
The dates reflected in the attachment are our best estimates at this time and may be subject to change. The following informatien is provided:
1.
Equipment description (type, model, manufacture).
2.
The system where tne equipment is installed.
3.
The test location and schedule.
The cognizant licensee contact for the environmental qualification tests is Mr. T. R. Burns, Project Engineering Manager.
If you have any questions please contact Mr. Burns or myself.
Sincerely
\\
b1020*c:(JC6 Y9 1
S. W. Shields l
GAS /cg P.O. Box 190, New Washington, Indiana 47162 812. 293.4441
PUBUC SERVICE INDIANA Letter:
Mr. Eisenhut December 18, 1980 cc:
Mr. James G. Keppler, Director U. S. Nuclear Regulatory Commission Region III Glen Ellyn, Illinois 60137 E. R. Schweibinz, P. E.
J. J. Harrison l
l l
t l
l l
l I
l l
l t
l i
LISTING OF SAFETY-RELRTED EQUIPMENT TO BE OUALIFIED FOR PiARBLE IIILL NUCLEAR GENERATING ATION - UNITS 1 RND 2 Tvpo-
!!anufacture Model System ~
Fuarterl Schedule Location Thermostat Switch Allen Bradley 837-V2J Diesel Generator 2nd. - 1981 Iluntsville,A14 WVIe Labs RTD Thermo Electric 16311-0900 9oleneid Valve Circle Seal N2990-9637-1 In Testing Interlock Switch Micro Switch BZE6-2RO 2nd. - 1981 Pressure Switch ASCO SBilA 2nd. - 1981
'iner & Solenoid In ersoll-Rand 15T2 2nd. - 1981 Level Switch Ge.s Sensor Div.
LS-1900 2nd. - 1981 Temperature Switch Allen-Bradicy 837-A4J-X706 2nd. - 1981 Differential Press. Sw.
United Electric J27KB-232 2nd. - 1981 Differential Press. Sw.
Barksdale DPD1T-M3SS 2nd. - 1981 Terminal Block Ge.eral Electric CR2960SY 139C3C 2nd. - 1981 Motor Control Center Westinghouse Five-Star Auxiliary Power 3rd. - 1981 Westinghouse Chicago Timer Agastat E7012AE&PD IIVAC 4th. - 1982 Hot Known
'"emp. Controller United Electric C303-103 IIVAC 4tl. - 1982 Not Known F302-5BS Lugs & Splices Ari?
53415-1 4th. - 1982 53416-1 4th. - 1982 53418-1 4th. - 1982 52980 4th. - 1982 52979 4th.
M82 53935 4th. - 1982 52941 4th. - 1982 Scienoid Valve ASCO NP8320A172E 4th. - 1982 Fuse Bussman FRN-30 4th. - 1982 Cable General Electric
- SIS 57275 4th. - 1982 SIS 58764 4th. - 1982 Pull Out Gould ITE-P302-C 4th. - 1982 Terminal Block General Electric CR151B2 4th. - 1982 Pressure Switch solca PS11DW 4th. - 1982 Trans former General Electric 9T51B104 4th. - 1982 Controller Love 541-838-851-8134-8174 4th. - 1982 54-8115-851-8134-8174 4th. - 1982 5 witches Westinghouse OTS1W & W-2 4th. - 1982 Relay Westinghouse 880AR 4th. - 1982 Analog Instrumentation Westinghouse 7300 Line BOP Control System In Testing Westinghouse NSSS Equipment Westinghouse Refer to WCAP 8587 Pittsburgh Ba tte ry Gould MCX-340 D. C. System 1st. - 1982 Kankakee, Ill.
NCX-600 FPS-13 L
' Typs Manufacturer Model System.
Schedule Location (quarter) i
'lotor/ Blower Reliance / Fan Eng. Co., Inc.
J-554 Ilydrogen Recombiner 1st. - 1981 Norco, CA.
N139000181-01 Wyle Labs Motor / Blower.
Reliance /Rotron N00lST770605-04 same j