Ack Receipt of 800826 Final Deficiency Rept Re Nonconforming Threads on 3.5-inch Diameter Studs & Nuts for NSSS Steam Generator Lateral Supports
ML19347C273
Person / Time
Site: Callaway Ameren icon.png
Issue date: 09/29/1980
From: Fiorelli G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Bryan J
UNION ELECTRIC CO.
Shared Package
ML19347C274 List:
References
NUDOCS 8010170173
Download: ML19347C273 (1)


Text

'

+*ga maf&q#

UNITED STATES 0,,

NUCLEAR REGULATORY COMMISSION S

REGloN 111 e

'f 799 ROOSEVELT ROAD

/

GLEN ELLYN, ILUNO15 6007 SEP 2 9 1980 Docket No. 50-483 Union Electric Company ATTN:

Mr. John K. Bryan Vice President - Nuclear P:st Office Box 149 St. Louis, MO 63166 Gentlemen:

Thank you for your final report dated August 26, 1980, pursuant to 10 CFR 50.55(e) regarding NSSS lateral support anchor bolt nuts.

We will complete our review of this matter during a future inspection.

Your cooperation with us is appreciated.

Sincerely,

/6 19&mt "Cfft-Reactor Construction and Engineering Support Eranch cc: Director, RCI/IE Directo, AE0D Chief, OEB/MPA IE Files Mr. W. H. Weber, Manager Nuclear Construction cc w/1tr dtd 8/26/80:

Central Files PDR Local PDR NSIC TIC i

Regions I & IV Ms. K. Drey Mr. Ronald Fluegge, Utility Division, Missouri, Public Service Commission

" 01 0170l73