ML19347C197

From kanterella
Jump to navigation Jump to search
Forwards Mechanical Engineering Branch Position on Facility Leak Testing Program Re RCS Pressure Isolation Valves.W/O Encl
ML19347C197
Person / Time
Site: Farley 
Issue date: 09/29/1980
From: Bosnak R
Office of Nuclear Reactor Regulation
To: Schwencer A
Office of Nuclear Reactor Regulation
References
NUDOCS 8010170011
Download: ML19347C197 (1)


Text

-

' A) h,-

REGCLU0!lY DCCKET FM COPY Q ggQ m 2 91980 MEHORANDUM FOR:

A. Schwencer, Chief Licensing Branch f2 Division of Licensing FROM:

Robert 'J. Bosnak, Chief Mechanical Engineering Branch Division of Engineering

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION - FARLEY UNIT NO. 2 -

REACTOR COOLANT SYSTEM (RCS) PRESSURE ISOLATION VALVES Following recent discussions with L. Kintner and the applicant it has been detemined that additional inforation is required to evaluate the adequacy of their leak testing program for RCS pressure isolation valves. Leak testing is required to reduce the probability of an intersystem LOCA caused by the RCS high pressure fluid comunicating with low pressure systems. All pressure isolation valve configurations sh uld be addressed (including event V) by the applicant.

L. Eintner of DL has a copy of the draft staff position and request for infomation discussing this matter. Enclosed please find the final version (withnochanges). We understand that the applicant has received our request and will asspood at possibles eq #cteter 13, U'01 at 5thech, "d.

Robert J. Bosnak, Chief Mechanical Engineering Branch Division of Engineering

Enclosure:

As stated cc:

J. Knight, DE A. Cappucci, DE D

suTION H. Bramer, DE MEB Meters F. Cherny, DE R. Birkel, DL ocket (50-764h NR m

R. Tedesco, DL Local POR L. Kintner DL MEB Reading NRR Reading

Contact:

RJBosnak A. J. Cappucci, DE:MEB X29476 st C

.. 1 OFFICE h SURNAME)

..lb.

..ECherny.

.RJBosna c.

DATE

..h

/.60

. 9/j7)./80.

9/df/.80.

j.

DU 1979-289 369 NAC FORM 318 (9-76) NRCM 0240 0 01 01 7<1 0 I I.S. GOVERNMENT PRINTING OFFICE.