O
.v NOTICE OF VIOLATION Based upon the results of the NRC inspection conducted on June 18, 1980, one of your activities appears to be in noncompliance with NRC regulations as indicated below:
Contrary to 10 CFR 71.5, a shipment of licensed material was delivered to a carrier for transport that did not comply with the applicable require-ments of the Department of Transportation.
Specifically, two containers in your shipment of June 3, 1980, contained sufficient radioactive material to yield exposure rates at contact of 80 and 70 mR/ hour.
These levels exceed radiation levels specified in 49 CFR 172.403(c)(1) for the radio-active yellow II label and the containers were therefore improperly labeled.
This item is considered category III.
l l
l l
l l
l l
l 8010140 yqo
U.S. Nuclear Regulatory Commission Office of Inspection and Enforcement Region IV IE Report No. 50-274/80-02 Docket No. 50-274 i
Licensee:
United States Department of Interior Geological Survey Denver Federal Building Denver, Colorado 80225 Facility Name:
USGS Research Reactor Inspection at:
Richland, Washington Inspection on: June 18, 1980 Inspector:
See attached report Approved by:
Glen D. Brown, Chief, FFMS Branch, RIV Date Summary:
See attached NRC RegionIV Report No.
80-74 1