Amend 54 to License DPR-59,changing Tech Specs in Response to 810326 Application Re Interim Mod of Safety Relief Valve Setpoints
ML19345G764
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 04/13/1981
From: Ippolito T
Office of Nuclear Reactor Regulation
To:
Shared Package
ML19345G765 List:
References
NUDOCS 8104220240
Download: ML19345G764 (5)


Text

.

O

/pa roog)

UNITED STATES yy g

NUCLEAR REGULATORY COMMISSION g

C WASHINGTON, D. C. 20555

%...../

POWER AUTHORITY OF THE STATE OF NEW YORK DOCKET NO. 50-333 yAMES A. FITZPATRICK NUCLEAR POWER PLANT AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 54 License No. DPR-59 1.

The Neclear Regulatory Comission (the Comission) has found that:

A.

',he application for amendment by Power Authority of the State of New York (the licensee) dated March 26, 1981, complies with the standards and req)uirements of the Atomic Energy Act of 1954, as amended (the Act and the Comission's rules and regulations set fortn in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issue.nce of this amendment will not be inimical to the comon defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifi-cations as indicated in the attachment to this license amendment, and paragraph 3.8 of Facility Operating License No. DPR-59 is hereby amended to read as follows:

18G0422e $o

W (B) Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No 54, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of its issuance.

FOR THE NUCLEAR REGULATORY COMMISSION

-- ?

Thomas ppolito, Chief Operating Reactors Branch #2 Division of Licensing

Attachment:

Changes to the Technical Specifications Date of Issuance: April ' 13,1981 i

l l

l e

---.,----,-,e

~,,., -

~.,,., _,. - - -,,,, -

-.., - ~,

ATTACHMENT TO LICENSE AMENDMENT NO. 54

{

FACILITY OPERATING LICENSE NO. OPR-59 DOCKET N0. 50-333 Replace the following pages of the Appendix "A" Technical Specifications with the enclosed pages.

Remove Insert 27 27 27a i

e l

l l

l

, - - -, ~,,,,,,...

,n----,-,w.

,,,,-.c

-c..n-,

w

,,--r,,,,,

JAFNPP l

1.2 REACTOR coo!. ANT SYSTEM 2.2 REACTOR COOIJufr SYSTEM APPLICABILITY:

APPI.ICABII.ITY:

Applies to limits on reactor coolant Applies to trip settings of the instru-system pressure.

ments and devices which are provided to prevent the reactor coolant system safety limits from being exceeded.

I OBJECTIVE:

OBJECTIVE:

To establish a limit below which the To define the level of the process integrity of the Reactor Coolant System variables at which automatic protective is not threatened due to an overpressure action is initiated to prevent the safety condition, limits from being exceeded.

SPECIPICATION:

SPECIFICATION:

1.

The reactor coolant system pressure 1.

The Limiting Safety System setting shall not exceed 1,325 psig at any shall be specified below:

time when irradiated fuel is present in the reactor vessel.

A.

Reactor coolant high pressure scram shall be 5 1,045 psig.

B.

Reactor coolant system safety / relief valve nominal settings shall be as follows:

Safety / Relief Valves 2 valves at 1090 psig 2 valves at 1105 sasig 7 valves at 1140 psia The allowable setpoint error for each safety / relief valve shall be + 1 percent.

Effective for fuel cycle 6 and thereafter. 27 l

Amendment No. [ fs,pf 54

JAFNPP 1.2 REACTOR CDOt. ANT SYSTEM 2.2 REACTOR COOIJuff SYSTEM i

APPLICABILITY:

APPI.ICABILITY:

Applies to limits on reactor coolant Applies to trip settings of the instru-1 system pressure.

ments and devices which are provided to prevent the reactor coolant system safety limits from being exceeded.

OBJ ECTIVE:

OBJECTIVE:

To establish a limit below which the To define the level of the process integrity of the Reactor Coolant System variables at which automatic protective is not threatened due to an overpressure action is initiated to prevent the safety condition.

limits from being exceeded.

l i

SPECIFICATION:

SPECIFICATION:

l 1.

The reactor coolant system pressure 1.

The Limiting Safety System setting shall not exceed 1,325 psig at any shall be specified below:

time when irradiated fuel is present in the reactor vessel.

A.

Reactor coolant high pressure scram shall be 6 1,045 psig.

B.

Reactor coolant system safety / relief

'~

s valve nominal settings shall be as l

follows:

I Safety / Relief Valves i

3 valves at 1090 peig l

i 2 valves at 1105 usig 6 valves at 1140 psia l

l The allowable setpoint error for each I

safety / relief valve shall be + 1 percent.

l 2h This page is effective until a cold shutdown of sufficient duration but 4

Amendment No. 54

~

in any case no later than the next cald shutdown for refueling.

i