Form NRC411s tji NUCLEAR REGULATORY CoMMISSloN CERTIFICATE OF COMPLIANCE 10 R 71 For Radioactive Materials Packsges 1.(d) Pages No. 1.(e) Total No. Pages I

  • toontification No.

1.(a) Certifw:ste Number 1.(b) Revision No.

1.(c)

Pack YSA/6581/B( )F 1

4 6581 14

2. PREAMBLE 2.lal This certificate is issued to satisfy Sections 173.393a,173.394.173.395, and 173.396 of the copertment of Transportation Hazardous Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146--19-100 of the copertment of Transportation oangerous Cargoes Regulations (46 CFR 146-149), as amended.

2.(b)

The packaging and ccMtents described in item s below, meets the safety standards set forth in Subpart C of Title 10 Code of Federal Regulations, Part 71," Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions."

2.tc)

This certificate does not relieve the consignor fro n compliance with any recuirement of the regulations of the U.S. Copartment of Transportation or other aoolicaole regulatory agencies.ncluding the government of any country through or into which the package will be transoorted.

3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.(a)

Prepared by (Name and address):

3.(b)

Title and identification of report or application:

EXXON Nuclear Company, Inc.

EXXON Nuc' lear Company, Inc. application dated 2955 Geroge Washingten Way June 15, 1979, as supplemer.ted.

Richland, WA 99352 3.(c)

Docket No.

71.ggg]

4.

CCNDITIONS This ce tificate is conditional uper_ the fulfilling of tMe requererMnts of Subpart D of 10 CFR 71, as applicaolo, and tne conditions scecified in item s below.

5. Oescr:ption of Pacmaging and Autnented Centents, Yodel Nurr-ber. Fissile Class. Other Conditions, and Aeferences:

(a) Packaging (1) Model Nos.:

51032-1 and 51032-la (2) Description A steel shipping container for fuel bundles, consisting of a strongback and fuel bundle clarping assembly, shock mounted to a steel outer container.

Minimum 3/8" thick wall, 6" x 8" x 8-1/2" long steel separators are bolted between fuel bundles. Outer container is approximately 43" diameter by 216" long. The maximum weight of the package is 7,400 pounds for the Model No. 51032-1 and 8,300 pounds for the Model No. 51032-la.

(3) Drawings The Model Nos. 51032-1 and 51032-la are constructed in accordance with EXXON Nuclear Company, Inc. Drawing Nos.:

l XN-NF-303,359, Sheet 1, Rev.1 XN-NF-303,360, Sheet 1, Rev. 1 XN-NF-303,364, Sheet 1, Rev.1; end Package-separate block, shock mount, and fuel elemerit clamp assembly requirements must be in accordance with Tables 2-II thru 2-IX (pp 2-16 thru 2-23) of the application; and 810422023I.

1

~

Page 2 - Certificate No. 6581 - Revision No. 14 - Docket No. 71-6581 5.

(a) Packaging (continued)

(3) Drawings (continued)

The Model No. 51032-1 is constructed in accordance with EXXON Nuclear Company, Inc. Drawing Nos.:

XN-NF-303,890, Sheet 1, Rev. 0 XN-NF-303,891, Sheet 1, Rev. 0 XN-300,609, Sheet 1, Rev. 1 XN-NF-303,898, Sheet 1, Rev. 0 XN-NF-303,897, Sheet 1, Rev. O and Jersey Nuclear Company Drawing Nos.:

JN-300,607, Sheet 1, Rev. 0 JN-600,843, Sheet 1, Rev. 3 JN-600,844, Sheet 1, Rev. 2; or The Model No. 51032-la is constructed in accordance with EXXON Nuclear Company, Inc. Drawing Nos.:

XN-NF-303,354, Sheet 1, Rev. 2 XN-NF-303,357, Sheet 2, Rev. 1 XN-NF-303,355, Sheet 1, Rev. 1 XN-NF-303,358, Sheet 1, Rev.1 XN-NF-303,356, Sheet 1, Rev. 1 XN-NF-303,818, Sheet 1, Rev. 0 XN-NF-303,357, Sheet 1, Rev. 1 (b) Contents Type, form, and maximum quantity of material per package must be as follows:

fuel assemblies as follows:

(1) UO or unpressurized (Atm pressure) Pu0 -UO2 2

2 Maximum No. of Radioactive Material Fissile Constitutents Assemblies per Fuel Type" (kg/ Package)

(kg/ Package)

Package TYPE I U

362 U-235 7.6 2

Pu 2.5 Pu 2.0 f

TYPE II U

510 U-235 16.0 4

Pu 6.0 Pu 4.8 f

3 TYPE III U

510 U-235 23.0 4

Pu 6.3 Pu 5.0 f

3 aSee Tables 2-XV thru 2-XIX and 12-XIV of application for the limiting physical characteristics of each fuel type.

Page 3 - Certificate No. 6581 - Revision No. 14 - Docket No. 71-6581 5.

(b) Contents (continued)

Maximum No. of Radioactive Material Fissile Constitutents Assemblies per a

Fuel Type (kg/ Package)

(kg/ Package)

Package TYPE IV U

240 U-235 5.0 2

Pu 1.8 Pu 1.4 f

D A

U 700 U-235 24.5 2 or 4 b

B U

1,500 U-235 52.5 2 or 4 b

C U

1,500 U-235 60.0 2 or 4 b

D U

1,500 U-235 60.0 2 or 4 b

E U

1,500 U-235 60.0 2 or 4 b

F U

1,500 U-235.

75.0 2 or 4 c

AA U

1,100 U-235 38.5 2

bTwo (2) fuel elements of standard length or four (4) short elements of equivalent weight.

cAuthorized for shipment only in Model No. 51032-la container.

A single (1) fuel rod may be added to the above packaging in accordance with Paragraph 12.4.3.4 (pp 12-19 and 12-20) of the application.

(2) Sintered uranium oxide pellets as Zr clad fuel rods packaged within the inner wooden container described by EXXON Nuclear Company, Inc. Drawing No. XN-301,901, Rev. 1.

The package may contain up to nine (9) fuel rods having a maximum enrichment of 5.0 wt% U-235 with a maximum pellet diameter of 0.5 inches.

Inert Zr rods may be additionally included.

(3) Contents as described and limited by Exxon Nuclear Company, Inc. letter dated January 2, 1981.

(c) Fissile Class I and III (1) Class I

' Types I, II, IV, A, 8, and AA described and limited in 5(b)(1).

(2) Maximum number of packages (1) Types III, C, D, E, and F, per shipment as Class III assemblies described and limited in 5(b)(1);

Eight (8) packages

Page 4 - Certificate No. 6581 - Revision No.14 - Docket No. 71-6581 (c) Fissile Class (continued)'

(ii) For the contents described and limited in 5(b)(2) or 5(b)(3);

One (1) package 6.

Each fuel assembly must be enclosed in an unsealed polyethylene sheath which will not extend beyond the ends of the fuel assemblies. Tha ends of the sheaths must not be folded or taped in any manner that would prevent the flow of liquids into or out of the sheathed fuel assemblies.

Polyethylene shims and ethafoam pads may be used in the packaging of fuel assemblies in accordance with p. 2-6 and Table 12-XIV of the application.

7.

The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).

8.

Expiration date:

July 31, 1985.

REFERENCES EXXON Nuclear Company, Inc. application dated June 15, 1979.

Supplements dated:

Novemcer 30, 1979; June 13 and August 6 and 15, 1980; and January 2 and ' 5,1981.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION Mk Charles E. MacDonald, Chief Transportation Certification Branch j

Division of Fuel Cycle and Material Safety Date:

l l

5

,n.

-