ML19345G242

From kanterella
Jump to navigation Jump to search
Forwards LER 81-019/03L-0
Date released: 12/25/2019 Download: ML19345G242


LER 81-019/03L-0:on 810214,at 100% Power,Auxiliary Feedwater Overspeed Trip Valve Tripped Twice,Rendering Feedwater Pump Inoperable.Caused by Improper Alignment of Linkage Parts.Parts Machined & Pump Returned to Svc
ML19345G243
Person / Time
Site: North Anna 
Issue date: 03/13/1981
From: Cartwright W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19345G243 (3)
Forwards LER 81-019/03L-0
ML19345G241
Person / Time
Site: North Anna 
Issue date: 03/13/1981
From: Cartwright W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19345G241 (1)