Forwards Design Criteria for Effluent Monitoring,Sampling & Analysis.Components Possibly Beyond Current state-of-the-art Included in Design.Ability to Meet Schedule Depends on Availability of Required Components
ML19345F589
Person / Time
Site: Sequoyah  
Issue date: 02/12/1981
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: Schwencer A
Office of Nuclear Reactor Regulation
Shared Package
ML19345F590 List:
References
RTR-NUREG-0737, RTR-NUREG-737, TASK-2.F.1, TASK-TM NUDOCS 8102180473
Download: ML19345F589 (1)


Text

. '.

7 E.N N E 5 M E '/ A L L E Y A UT"C R!~Y

..-.,....-,.-3 400 Chestnut Street Tower II February 12, 1981 C

Director of Nuclear Reactor Regulation Attention:

Mr. A. Schwencer, Chief Licensing Branch No. 2 Division of Licensing U.S. Nuclear Regulatory Co= mission 7

Washington, DC 20555 s

Dear Mr. Schwencer*

In the Matter of the Application of

)

Docket Nos. 50-327 Tennessee Valley Authority

)

50-328 In response to NUREG-0737 Item II.F.1, Additional Accident Monitoring Instru=entation, Part 1, Noble Gas Effluent Monitor, and Part 2, Sampling and Analysis of Plant Effluents, enclosed is TVA's design criteria for these syste=s at Sequoyah Nuclear Plant.

The design described in the enclosure requires components which may be beyond the current state of the art. TVA is continuing to work on pro-curement of the required components and installation of the system in accordance with the schedule described in our letters to you dated December 19 and December 31, 1980. However, our ability to meet this schedule depends on the availability of the required components.

Interim measures for additional accident monitoring instrumentation were described in our response to NUREG-0578.

If you have any questions, please get in touch with D. L. Lambert at FTS 857-2581.

Very truly yours, TENNESSEE VALLEY AUTHORITY L. M. Mills, Manager Nuclear Regulation and Safety Sworn to d subscribed before me this7/

day o. /_.1,

1981 g[

Aid I

/11LKr Not'aryj ublic

~

&[

ADD.'

4E j

My Ce ssion Expires I[

/ /

Dy. b2., DN '

Enclosure Don, D G I

I l

put, D L DeRD$t i I 8102180 Q D ok. bS T