ML19345D848

From kanterella
Jump to navigation Jump to search
Forwards LER 80-052/03L-0
Date released: 12/25/2019 Download: ML19345D848


LER 80-052/03L-0:on 801118,recirculation Discharge Valve Activation Pressure Switch 3-PS-68-95,switch 1,found Below Tech Spec Limit by 8%.Caused by Instrument Drift.Switch Recalibr & Tested.Switch to Be Replaced
ML19345D854
Person / Time
Site: Browns Ferry 
Issue date: 12/15/1980
From:
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19345D854 (2)
Forwards LER 80-052/03L-0
ML19345D847
Person / Time
Site: Browns Ferry 
Issue date: 12/15/1980
From: Green H
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19345D847 (1)