Docket Nos: 50-369/370 MEMORANDUM FOR:
B. J. Youngblood, Chief Licensing Branch 1, 00L FROM:
Olan D. Parr, Chief Auxiliary Systems Branch, DSI
SUBJECT:
MEETING SUNRY FOR VISIT TO MCGUIRE NUCLEAR STATION Attached are our minutes to the McGuire site visit of October 28 and 29, 1980, for your issuance.
arr ef Auxiliary Systems Branch Division of Systems Integration
Attachment:
As stated cc:
D. Ross D. Eisenhut P. Check R. Tedesco R. Birkel V. Leung
Contact:
V. Leung x28241 l
j
.8012120 237 t
i i
Docket No. 50-369/370 Applicant: Duke Power Company Facility:
McGuire Nuclear Station, Units 1 and 2 Summary of meeting held to discuss McGuire Auxiliary Feedwater System Reliability Evaluation
Background
The Reliability and Risk Assessment Branch (RRAB), utilizing the Sandia Laboratory personnel as consultants, are evaluating the Duke Power Company's reliability evaluation of the auxiliary feedwater system as prepared for the McGuire Nuclear Station. A visit was made to the McGuire site to provide RRAB and Sandia personnel as well as Auxiliary Systems Branch personnel, i
an opportunity to view the actual installation of the auxiliary feedwater system and to discuss RRAB and Sandia questions.
A list of meeting attencees is provided in Enclosure 1.
Discussion A meeting was held with the Duke Power Company on October 28 and 29,1980, to discuss the applicant's reliability evaluation of the auxiliary feedwater system for the McGuire Nuclear Station. The morning portion of the October 28, 1980 meecing took place at the McGuire site. Duke personnel provided a description of the auxiliary feedwater system design.
The McGuire system is unique in the manner in which the two train system is evaluated. One train consists of two sub-trains each consisting of a motor driven pump. Each sub-train will supply flow to two steam generators.
A second train utilizing a single turbine driven pump will supply flow to all four steam generators.
_2 Water to the suction of the pumps is supplied from several non-safety grade water sources; upper surge tanks, condenser hot well, condensate storage tanks and condensate hot well; and one safety grade water source, the nuclear service water.
In order to provide the minimum auxiliary feedwater (AFW) flow requirement (450 gpm) to the steam generators in the event of a main feed line break accident, the control valves in the AFW intake line to each steam generator are provided with mechanical stops. This arrangement will ensure that 450 gpm of feedwater can be pumped to the three intact SGs automatically as the control valve in the line to the fourth steam generator acts as an orifice which limits the loss of flow from the system.
This presentation was followed by a visit into the plant to view the actual installation.
The remaining portion of the meeting took place 'at the Duke Power headquarters office in Charlotte. The applicant and their NSSS vendor, Westinghouse, presented a detailed description of McGuire's AFW system reliability analysis report. Westinghouse personnel described the assumptions, data and the mechanical model used to evaluate the system reliability.
As indicated in the reliability analysis report, the McGuire system falls below the reliability characterizations for many of the operating Westing-house plants (as given in NUREG-0611), especially in a loss of main feed-water accident.
In an attempt to explain the McGuire system's low reliability,
the applicant suggested that it was caused by the inclusion of an additional consideration, i.e. rupture of main feedwater line, when loss of main feedwater accident was evaluated. For the operating Westinghouse plants some form of operator action is required in 10 minutes. For McGuire this tine has been increased to 30 minutes.
In order to obtain this time change, however, the control valves weit orificed as discussed above. Otherwise the McGuire system'would have the same reliability as the other operating plants.
The applicant indicated that a formal response to the questions previously forwarded by the NRC, and modified during the two days of discussio,n, would be provided later.
Subsequent to the site visit, the applicant by letter dated November 10, 1980, submitted a respond to the above cited questions.
I i
l
4 l
Auxiliary Feedwater Reliability NRC - E - Duke Meeting October 28, 1980 Bill Shopsky E
PRA Doug Wood W
PRA G. A. Copp Duke Steam Production Ilmar Raisep E
Licensing Ken Canady Duke Steam Production S. D. Alexander Duke Design M/N D. L. Camp Sandia Division 1222 Armand Lakner NRC NRR,RRAB O. D. Parr NRR.DSI,ASB Branch Chief V. Leung NRR.DSI,ASB G. L. Fidler E
, Projects d
I
.i-i N
-.---e c-
.m,
NOV-25 1939 h[gil![shhkfhb
SUMMARY
D@!BUTION Docket File G. Lear NRC PDR 1900 NOV 28 iM. 9 07 V. Noonan Local PDR
- 5. Pawlicki TIC /MSIC/ Tera V. Benaroya NRR Reading c3 NRC Z. Rosztoczy LBal Reading F3i";JiiON SERV!CES W. Haass H. Denton Nd D. Muller E. Case R. Ballard D. Eisenhut W. Ret,an R. Purple D. Ross B. J. Youngblood P. Check A. Schwencer R. Satterfield F. Miraglia
- 0. Parr J. Miller F. Rosa G. Lainas W. Butler R. Vollmer W. Kreger J. P. Knight R. Houston R. Bosnak T. Murphy F. Schauer L. Rubenstein R. E. Jackson T. Speis Project Manager R. A. Bi rkel W. Johnston Attorney, OELD J. Stolz M. Rushbrook S. Hanauer OIE (3)