ML19345C651
| ML19345C651 | |
| Person / Time | |
|---|---|
| Site: | Marble Hill |
| Issue date: | 11/24/1980 |
| From: | James Keppler NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| To: | Shields S PSI ENERGY, INC. A/K/A PUBLIC SERVICE CO. OF INDIANA |
| References | |
| NUDOCS 8012080071 | |
| Download: ML19345C651 (2) | |
Text
'
p @ ttoq 4
UNITED STATES
<y 8
3,,
NUCLEAR REGULATORY COMMISSION t
.e REGION lli g,
p*/
7se ROOSEVELT ROAD
- g GLEN ELLYN. ILLINOIS 60137 November 24, 1980 Those on Attached Address List:
The enclosed IE Information Notice No. 80-42 is provided as an early notification of a possibly significant matter. Recipients of this notice should review the information for possible applicability to their facilities. However, no specific action or response is requested at this time.
If further h3C evaluations so indicate, an IE Circular or Bulletin will be issued to reconnend or request specific licensee actions.
If you have questions regarding this matter, please contact this office.
Sincerely, M.k
. James G. Keppler
' Director
Enclosure:
IE Information Notice No. 80-42 i
l
+
d p p0&f1 L
'S DocketLNo. ISO-546' Docket No. 50-547' Public-Service of Indiana ATTN:
Mr. S. W.' Shields Senior Vice President
- Nuclear Division -
Post Office Box 190 New Washington, IN 47162
'cc w/ encl:
' Steve J. Brewer, Nuclear Safety a
Licensing Supervisor ral Files AD/ Licensing AD/ Operating Reactors
~
PDR Local PDR NSIC TIC LeBoeuf, Lamb, Leiby & MacRae Dave Martin, Office of the Attorney General John R. Galloway, Staff Director, Environment, Energy and Natural' Resources Subcommittee l
as vv Y
t^
E a
<>A5 w
cv r.x Aa1
.A
~ hhh
.{
w
'e r <
s I'.', $
Y*,
$f
' ((;
,8
..n.
e,. -,., -,
,. -c.
, y
.-m.. - -
SSINS No.:
6835 Accession No.:
UNITED STATES 8008220261 NUCLEAR REGULATORY COPHISSION IN 80-42 0FFICE OF INSPECTION AND ENFORCEMENT WASHINGTON,D.C.
20555 November 24, 1980
/
IE Information Notice No. 80-42:
EFFECT OF RADIATION ON HYDRAULIC SNUBBER FLUID Description of Circumstances:
On August 7, 1980, Florida Power Corporation (FPC) filed a report in accordance with 10 CFR Part 21 that identified an upper service limit of 10 Mrad (megsrad) of radiation on the General Electric Versilube F-50 fluid that was provided in Anker-Holth shock suppressors mounted on the reactor coolant pumps.
This upper limit was obtained from the results of a study performed for FPC by Rensselaer Polytechnic Institute (RPI).
These results contained two items of prime importance to the operation of the suppressors.
The first result was a significant increase of the viscosity of the fluid to the extent that incipient gelation of the fluid occurred at exposures of approximately 50 Mrad.
The viscosity increased linearly for exposures up to 20 Mrad and then increased exponentially for exposures greater than 20 Mrad.
The second result showed that hydrochloric acid (hcl) was formed in significant quantities when the fluid was subjected to radiation.
The following table lists the dose irradiation time and hcl formed.
Dose Irradiation hcl Formed (Mrad)
Time (ppm) 0 2.78 1.2 1 minute 70.3 5.8 5 minutes 329.
5.8 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> 335.
18.5 11.2 minutes 555 50.3 15.2 minutes 1592 One of the recommendations by the RPI personnel was that the fluid be replaced before a limit of approximately 6 Mrads was reached.
FPC reported that the fluid in service at Crystal River No. 3 plant had absorbed doses ranging from 2.3 to 3.6 Mrads,these values were determined by comparing the viscosity of the fluid in service to that of the test samples at RPI.
The Technical Instruction Manual that is provided by the vendor for these suppressors contains a recommendation that 12.5 Mrads should be the maximum service life for Versilube F-50.
This IE Information Notice is provided as an early notification of a possibly significant matter that is still under. review by the NRC staff.
Recipients should review the information for possible applicability to their facilities.
No specific action or response is requested at this time.
If NRC evaluations so indicate, further licensee actions may be :equested or required.
IN 80-42 November 24, 1980 Page 2 of 2 No written response to this IE Information Notice is required.
If you have any questions regarding this matter, please contact the Director of the appropriate NRC Regional Office.
T
.~-
IN 80-42 November 24, 1980 RECENTLY ISSUED IE INFORMATION NOTICES 1
i Information Date of Notice No.
Subject Issue Issued to 80-41 Failure of Swing Chcek 11/10/80 All power reactor Valve in the Decay Heat facilities with an OL Removal System at David-or CP Besse Unit No. 1 80-40 Failure Of Swing Check 11/10/80 All power facilities Valve In The Decay Heat with and OL or CP Removal System At Davis-Besse Unit No. 1 80-39 Malfunctions Of Solenoid 10/31/80 All light water reactor Valves Manufactured By facilities holding Valcor Engineering Corporation power reactor OLs or cps 80-38 Cracking In Charging Pump 10/30/80 All PWR facilities Casing Cladding with an OL or CP 80-37 Containment cooler leaks 10/24/80 All nuclear power and reactor cavity facilities holding flooding at Indian Point power reactor OLs Unit 2 or cps 80-36 Failure of Steam 10/10/80 All nuclear power Generator Support Bolting reactor facilities holding power reactor j
OLs or cps 80-35 Leaking and dislodged 10/10/80 All categories G and Iodine-124 implant seeds G1 medical licensees 80-34 Boron dilution of reactor 9/26/80 All pressurized water i
coolant during steam reactor facilities generator decontamination holding power reactor OLs 80-33 Determination of teletherapy 9/15/80 All teletherapy timer accuracy (G3) licensees 80-32 Clarification of certain 8/12/80 All NRC and agreement requirements.for Exclu-state licensees sive-use shipments of 4
radioactive materials
- Operating Licenses or Construction Permits i
1
, _...,. -.