Fowards LER 80-086/03L-0
Date released: 12/25/2019 Download: ML19345A896


LER 80-086/03L-0:on 801024,during Routine Surveillance, Reactor Instrument Penetration Isolation Valve X51D Found W/O Position Indication.Caused by Valve Position Limit Switches Out of Adjustment.Switches Readjusted
ML19345A897
Person / Time
Site: Brunswick Duke Energy icon.png
Issue date: 11/19/1980
From: Tollison A
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19345A897 (2)
Fowards LER 80-086/03L-0
ML19345A895
Person / Time
Site: Brunswick Duke Energy icon.png
Issue date: 11/19/1980
From: Tollison A
CAROLINA POWER & LIGHT CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19345A895 (1)