ML19345A316

From kanterella
Jump to navigation Jump to search
Submits Proposed Change 20 to Tech Specs,Installing in Safety Injection Sys Piping,Two Valved & blanked-off Connections,Located in Safety Injection Pump Suction Header & Discharge Header
ML19345A316
Person / Time
Site: Yankee Rowe
Issue date: 03/12/1962
From: Coe R
YANKEE ATOMIC ELECTRIC CO.
To:
US ATOMIC ENERGY COMMISSION (AEC)
References
NUDOCS 8011190077
Download: ML19345A316 (3)


Text

t Pronosed Chance No. 20 YANKEE ATOMIC ELECTRIC COMPANY YA M.M 441 STUART STRE ET. BOSTON 16. MASSACHUSETTS March 12, 1962 hhh O ~ Ak IAR File Copy [.//ug.)

9 9

/@

h U. S. Atomic Energy Commission 4

Washington 25, D. C.

coc%w:

U g,y

_'1 9

Ucewn s'}!

fggy4,.s[gu,e.

Attention: Division of Licensing and Regulation 2

Refereno : License No. Dpa-3 (Docket No. 50-29) p A

Dear Sir.=

0)

,g pursuant to paragraph 3.A of License No. DPR-3, b

ed, Yankee Atomic Electric Company hereby requests authorization to make the following change FROPOSED CHANT : Reference is made to Section 212 of the license appli-cation, " Safety Injection System", and particularly to Drawing 646-J-644 which follows page 212:1 of the text. We propose to install in the Safety Injection Sy '

piping, two valved and blanked-off connections, one con-nection locat, in the safety injecticn pump suction header, the other s

located in the discharge header. The piping and valves to be used in maxing these connections will be of stainless steel construction.

Reascns for Chance:

In view of the possibility that reactor opera-tion at a higher power level than at present r.ay be authorized at some future time and based on preliminary analyses of reactor acci-dents at this higher power level, we feel that provision should be made now for future installation of an additional safety injection pump. The installation of the proposed blanked-off connections provides a means for connecting an additional safety injection pump to the system at any time in the future without requiring plant shutdown and cooling and depressurization of the main coolant system.

Safety Considerations:

In our opinion, the proposed change does not present cignificant hazards considerations not described or implicit in the license application, as amended to June 23, 1961, the date of iss"ance of Amendment No. 3 to License No. DFR-3, or as amended to the cate hereof, and does not affect the accident analysis set forth in Section 4 of the license application.

8011190077 g

(-

4.

U.S. Atomic Energy Coccission-Proposed Change No. 20 Attn.: Div. of Lic. and Reg.

March 12, 1962 Scheduling of Chance: The change will be made at the time of the next refueling shutdown to comply with paragraph D.2.e.(3) of the Technical Specifications.

. The proposed change requires authurization by the Commission pursuant to paragraph 3.A of the license, since it involves a change in the design specifications of the reactor which are set forth in the li-cense application and~ incorporated by reference in the Technical Speci-fications.

(See paragraph B-1 of Appendix A to License No. DPR-3.)

Enclosed herewith as supporting information for the proposed change is Drawing 646-J-644, revised to show the proposed connections.

Upon authorization of this change and upon completion of the work, a superseding drawing (Revision 5) will be submitted as an amend-ment to the license application.

Incorporation of the drawing in the license application will bring the document up to date so that it will reflect the actual physical condition of the plant.

Respectfully submitted, YANKEE ATQ4IC ELECTRIC COMPANY

)

ATLA l

Roger '. Coe,/Vi'ce President

(

Commonwealth of Massachusetts Suffolk, ss March 12, 1962 Then personally appeared before ce Roger J. Coe, who, being duly sworn, did state that he is a Vice President of Yankee Atomic Electric Company, that he is duly authorized to execute and file the foregoing request in the name and on behalf of Yankee Atomic Electric Company, and that the statements therein are true to the best of his knculedge and belief.

A~ of c% A-de%-

Donald G. Allen Notary Public My Co:=ission Expires Jan. 21, 1967

+

+.....

w:

.=

c--

~

-v

=

"o*' Yrr.kee Ato=1e Eleetric Com pny-...

^"*'"2*7'

^" "'CV5 Ec: ten 16, P.setschusetts Earch 12,1962 Esrch lb, 1062 2010

{ {p, 7 g, y }

LTR.

MEMO.

REPORTe CTHER.

Z TO.

L.

=

ORJG CC.

OTHER.

...(-.

Piv. cf Le 2h h L ei'd n {' k C, D. C.

ACTION NECESSARY O.

CONCURRENCE O

DATE ANSWEREDi NO ACTION NECESSARY Q COMMENT O

8 v' CLAS$tF.s PCST CFFICE FILE CODL Ur.cle.z sified 50-29

,, yo, DESCro.TICa (v nr 8. Mm ed) e REFERRED TO DATE RECE1YED BY DATE "Fropeusd Change Eo. 20" reEcrding the prom cd installctien to be r:cde into Dr. rrynn 3-1)-52

  • ea Ecfety In.icetien Eysten pipin~.

v/ file ey.(& folder not in Eiler. )

2-cen.11snce cre.

ENCLC5VRE5a

},gy{ygg h 'a EO. W J hh i

1-M00. TIS 7 1-T. nk 12m, T1 pg (g HAM U

"'"* hail Foca Distribution 1-Eolen Steele

{4

~ l 2-c3c d

1-h.b. roe. Rec..

871 1ve cr1 ym cr.

U O. 5. ATOMIC ENERGY CO""lSSON

  • u s. oomNuc.m m=N. omCc,.., _ m...

MAIL CONTROL FORM,0% AEC.m$

(8-60) r ww.MLt W

O p