ML19344F101

From kanterella
Jump to navigation Jump to search
Forwards LER 80-149/03L-0
Date released: 12/24/2019 Download: ML19344F101


LER 80-149/03L-0:on 800807,during Preoperational Tests, Turbine Driven Feedwater Pump Failed to Maintain Rated Rpm. Caused by Overheated Automatic Governor.Ventilation Damper Linkage Repaired & Governor Controls Replaced
ML19344F122
Person / Time
Site: Sequoyah 
Issue date: 09/04/1980
From: Gelston A
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19344F122 (3)
Forwards LER 80-149/03L-0
ML19344F100
Person / Time
Site: Sequoyah 
Issue date: 09/04/1980
From: Calhoun J
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19344F100 (1)