ML19344E737
| ML19344E737 | |
| Person / Time | |
|---|---|
| Site: | Westinghouse |
| Issue date: | 07/28/1980 |
| From: | Kenna W NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| To: | Damore M WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP. |
| Shared Package | |
| ML19344E733 | List: |
| References | |
| NUDOCS 8009110139 | |
| Download: ML19344E737 (2) | |
Text
ETERntTPX5Y!TTTIETIl O
C0ill/SS 2.7S31:JC." Mil 0N y.ag'o r
UNITED STATES es8 g
NUCLEAR REGULATORY COMMISSION o
E E
,E REGION il o
101 MARIETTA ST N.W., sus (E 3100 o
ATLANTA, GEORGIA 30303 In Reply Refer To:
L 2 a 1980 RII: GAT 70-1151/80-18 Westinghouse Electric Corporation ATTN:
M. D' Amore, Manager Columbia Plant Nuclear Fuel Division Drawer R Columbia, SC 29205 Gentlemen:
This ref2rs to the inspection conducted by G. A. Todd of this office on June 24-26, 1980, of activities authorized by NRC License No. SNM-1107 at Westinghouse Eleciaic Corporation and to the discussions of our findings held with M. D' Amore at the conclusion of the inspection.
Areas examined during this inspection included your program for nuclear material control and accountability under the applicable provisions of Title 10, Code of Federal Regulations, Part 70, "Special Nuclear Material", and specific license conditions. Within these areas, the inspection consisted of selective examina-tions of procedurt.s and representative records, interviews with personnel, performance tests, and observations by the inspector.
During the inspection, it was found that certain activities under your license appear to be t noncompliance with NRC requirements. This item and references to pertinent requirements are listed in the Notice of Violation enclosed herewith as Appendix A.
This notice is sent to you pursuant to the provisions of Section 2.201 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regula-tions. Section 2.201 requires you to submit to this office, within 20 days of your receipt of this notice, written statement or explanation in reply including:
(1) corrective steps which have been taken by you and the results achieved; (2) corrective steps which will be taken to avoid further acncompliance; and (3) the date when full compliance will be achieved.
Details of activities involving safeguards and security measures are exempt from disclosure in i
accordance with 10 CFR 2.790(d).
Therefore, your response should be incorporated in a separate paper and referenced in your reply.
I In accordance with Section 2.790(d) of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations, activities involving safeguards and security measures are exempt from public disclosure; therefore, the enclosures to this letter with the exception of the report cover page, which is an inspec-tion summary, will not be placed in the Public Document Room.
l 8009110/} }
mTmtTemsme.m CONIAli;S 2.75D IUO2!.Mir33
r exmiAtrm!smica maiTH JU L 2 31980 1
CONTA;t:5 2.12I:i?Di?.ria:t Westinghouse Electric Corporation Should you have any questions concerning this letter, we will be glad to discuss them with you.
- Siperely,
,f
/
W
/. B. '
rnna, Chief Safegu ds Branch
Enclosures:
1.
Appendix A, Notice of Violation (Exempt from Disclosure) 2.
Inspection Report No. 70-1151/80-18 (Exempt from Disclosure) 3.
Inspection Summary (Not Exempt) i l
i l
l
.t l
l l
MABIALTRANS.tiTTED llEREY!!TH c:m:::s.a rr m
s