ML19344E400

From kanterella
Jump to navigation Jump to search
Forwards IE Info Notice 80-30, Potential for Unacceptable Interaction Between Control Rod Drive Scram Function & Nonessential Control Air at Certain GE BWR Facilities. No Written Response Required
ML19344E400
Person / Time
Site: FitzPatrick 
Issue date: 08/19/1980
From: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Pasternak R
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
References
NUDOCS 8008280520
Download: ML19344E400 (1)


Text

2 : erg e

!(

UNITED STATF.S NUCLEAR REGULATORY COMMISSION o

,E REGION 1 e,

g 631 PARK AVENUE KING oF PRUSSIA, PENNSYLVANIA 19406 August 19, 1980 Docket No. 50-333 Power Authority of the State of New York J~nes A. FitzPatrick Nuclear Power Plant ATTN:

Mr. R. J. Pasternak Resident Manager P. O. Box 41 Lycoming, New York 13093 Gentlemen:

The enclosed IE Information Notice No. 80-30, " Potential for Unacceptable Interaction Between the Control Rod Drive Scram Function and Non-Essential Control Air at Certain GE BWR Facilities," is forwarded to you for information.

No written response is required.

If you desire additional information regarding this matter, please contact this office.

Sincerely, Tt?d6 W

i Bo ce H. Grier rector

Enclosures:

1.

IE Information Notice No. 80-30 2.

List of Recently Issued IE Information Notices CONTACT:

D. L. Caphton (215-337-5266) cc w/encls:

George T. Berry, President and Chief Operating Officer J. P. Bayne, Senior Vice President-Nuclear Generation A. Klausmann, Director, Quality Assurance M. C. Cosgrove, Site Quality Assurance Engineer J. F. Davis, Chairman, Safety Review Committee j

C. M. Pratt, Assistant General Counsel G. M. Wilverding, Manager-Nuclear Licensing l

.8 0 0 8 2 8 0 pp.o

(

SSINS No.:6870 Accession No.:

8006190057 IN 80-30 UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 August 19, 1980 IE Information Notice No. 80-30:

Pt,TENTIAL FOR UNACCEPTABLE INTERACTION BETWEEN THE CONTROL ROD DRIVE SCRAM FUNCTION AND NON-ESSENTIAL CONTROL AIR AT CERTAIN GE BWR FACILITIES Continued NRC evaluation of possible failure modes of the control rod drive system related to the Browns Ferry event (IE Bulletin 80-17), has identified a potentially significant single failure mechanism which could degrade the scram function.

The slow loss of non-essential control air pressure could degrade the scram function at certain facilities which have relatively poor communica-tion between the scram discharge volume (SDV) and the scram discharge instru-mented volume (SDIV) such that the SDIV drains more rapidly than the SDV drain rate into the SDIV.

The significance of such a single failure warrants transmission of an interim assessment by the NRC Office for Analysis and Evaluation of Operational Data as an early notification of a possibly significant matter that is still under review by the NRC staff.

It is expected that recipients will review the information for possible applicability to their facility.

No specific action or response is requested at this time.

If you have any questions regarding this matter, please contact the Director of the appropriate NRC Regional Office.

Enclosure:

Memo from C. Michelson to H. Denton, dated August 18, 1980 DUPLICATE DOCUMENT a

j Entire document previcusly entered into syster unier:

ENO WCClePf CO TW n

No. of pages:

[

._