Forwards Supplemental Response to Noncompliance Noted in IE Insp Repts 50-338/80-25 & 50-339/80-26.Corrective Actions: Sodium Bisulfite Now Utilized in Milk Sample Preservation Technique.Infraction Should Be Deleted or Made Open Item
ML19344E347
Person / Time
Site: North Anna  
Issue date: 08/25/1980
From: Sylvia B
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
585-A, NUDOCS 8008280431
Download: ML19344E347 (3)


Text

.

VINGINIA EI.ucrHIC AND POWHH COM PA NY H a cnwoxn,Vziao M ZA 20261 August 25, 1980 Mr. Jr.mes P. O'Reilly, Director Serial No. 585A Office of Inspection and Enforcement N0/RMT:ms Atta:

Mr. J. Philip Stohr, Chief Docket Nos. 50-338 Fuel Facility and Materials 50-339 Safety Branch License Nos. NPF-4 U. S. Nuclear Regulatory Commission NPF-7 Region II 101 Marietta Street, Suite 3100 Atlanta, Georgia 30303

Dear Mr. O'Reilly:

In reference to your letters of August 12, 1980 and June 24, 1980, and our letter dated July 18, 1980, Serial Number 585, regarding an apparent item of non-compliance reported in IE Report Numbers 50-338/80-25 and 50-339/80-26, we are forwarding the attached supplemental response.

Although previous corrective action was taken, we still recommend that the infraction be deleted or changed to an open item and we support that recommen-dation with Attachment 2 which corroborates our view.

Very ruly yours, k

B. R.

ylvia Manager - Nuclear Operations and Maintenance Attachment' cc:

Mr. Robert A. Clark, Chief Operating Reactors Branch No. 3 Mr. B. Joe Youngblood, Chief Licensing Branch No. 1 l

Division of Licensing

.8 0 0 8 280 af3;

ATTACHMENT 1 SUPPLEMENTAL RESPONSE TO NOTICE OF VIOLATION ITEM REPORTED IN IE INSPECTION REPORT NOS. 50-338/80-25 AND 50-339/80-26 Corrective Action Taken:

The procedure in question was revised and sodium bisulfite is now utilized in the milk sample preservation technique.

Date Full Compliance Was Achieved:

July 2, 1980.

T l

i

,[.

'rTEl-ME Page 1 of 2 ISOTOPES M VAN 0;. U. 4 6 uE WEMM% :.inJEassy OMrs (20'3 5%W3 TELid 13 4474 July 16,1980

'gg 2 2 ML 1930 S.P.S.

Mr D.H PPer gg g g g g W,W,C, Virginia Electric and Power Co.

North Anna Power Station P O Box 402 Mineral, VA 23117

Dear Mr. Hopper:

In the attached table are our results of stable iodide content in VEPCO nilks from February 1979 through June 1980. The pre-June 1980 samples have concentrations between < 0.03 (listed as 0.0) and 0.77 mg/ liter while the June 1980 values were between 0.56 and 0.81.

In the forper case there are 46 resuits; in the latter, only three.

Since there are only three results representing no addition of fomhldehyde I believe it is too early to draw a conclusion, especially since there are a few formaldehyde results in the range of the June 1980 results.

My interpretation of the Health Physics article by Montgomery and Gibson is that there can be a protein-bound iodine problem with milk samples using formaldehyde but that the data in the article is insufficient, even by the admission of the authors, to extrapolate the results to a generalization of the issue.

For example, according to the article the temperature of the milk at the time of the addition of formaldehyde can have a significant affect on the protein-binding.

The authors also admit that milk from other areas of the country (as opposed to the Cincinnati, Ohio area)..."may differ in oxidase activity, stable iodide concentration and other constituents that could affect protein hinding of formaldehyde-preserved milk".

Therefore as I mentioned in the first paragraph that I would consider it too soon after the change of the sample collection procedure of not adding formal-dehyde to pass judgement on this issue.

Sincerely, 0, AM 75@

J. David Martin, Manager Environmental Analysis Department JDM:a1 Enclosure

Attechm:nt 2 i..

1.

<5 Page 2 of 2 Stable Iodide Content in VEPCO Milk Samples Collection Date T I#

Iodide (ng/1) 2/26/79 63405 0.77 63406 0.14 63407 0.2S 3/19 64842 0.11 64843 0.11 64844 0.14 4/26 66752 0.77 66753 0.14 66754 0.28 5/23 68459 0.0 68460 0.04 68461 0.070 6/27 70367 0.0

'?36S 0.07

/

70369 0.07 7/19 72017 0.25 72018 0.42 72019 0.21 S/16 73635 0.07 73636 0.07 73637 0.11 9/17 75670 0.07 75671 0.46

,g 75672 0.04 10/18 77556 0.07 77557 0.11 11/15

-79099 0.39 79100 0.39 12/17 809S6 0.07 80987 0.07 809S3 0.11 1/16/80 82596 0.0 82597 0.07 82598 0.07 2/14 84340 0.14 84341 0.11 l

S4342 0.18 3/26 86175 0.56 86176 0.14 86177 0.11 4/24 SS122 0.63 88123 0.11 l

88124 0.14 5/22 90058 0.14 90059 0.14 90060 0.18 6/24 92131 0.56 92132 0.74 92133 0.81

.