05000366/LER-1980-118-03, /03L-0:on 800804,during Normal Operation,Drywell a hydrogen-oxygen Analyzer Failed.Caused by Instrument Drift of Reagent Gas Flowmeter.Reagent Gas Flow Was Adjusted to Correct Flow Rate.Analyzer Was Returned to Svc

From kanterella
(Redirected from ML19344E114)
Jump to navigation Jump to search
/03L-0:on 800804,during Normal Operation,Drywell a hydrogen-oxygen Analyzer Failed.Caused by Instrument Drift of Reagent Gas Flowmeter.Reagent Gas Flow Was Adjusted to Correct Flow Rate.Analyzer Was Returned to Svc
ML19344E114
Person / Time
Site: Hatch 
Issue date: 08/19/1980
From: Nix R
GEORGIA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19344E107 List:
References
LER-80-118-03L, LER-80-118-3L, NUDOCS 8008260644
Download: ML19344E114 (2)


LER-1980-118, /03L-0:on 800804,during Normal Operation,Drywell a hydrogen-oxygen Analyzer Failed.Caused by Instrument Drift of Reagent Gas Flowmeter.Reagent Gas Flow Was Adjusted to Correct Flow Rate.Analyzer Was Returned to Svc
Event date:
Report date:
3661980118R03 - NRC Website

text

...pm LICENSEE EVENT REPORT CONTROL BLOCK:'l l

l l

l l lh (PLEASE PRINT OR TYPE ALL REQUIRED INT ORMATION!

I b

l c l'A ! E f I l11 l 2 l@l 0 l0 l-l 0 l0 l0 l0 l0 l-l0 l0 l@l4 l1 l1 l1 l1l@l l

l@

O i 7

8 9 LICENSEE CODE 44 15 LICE N';L NUMBER 2b 20 LICLN5L T YPE JO b F 4A l M CON'T Eny l L l@l 0 l 5 l 0 l 0 l0 l 3 l 6 l6 @l0 l8 l0 l418 l0 l@l Ol 8l Il 91 8l 0l@

C 1 7

8 00 63 OOCKET NUUDER to 6'J EVEN'DATE 74 7b REPORTDATE 80 EVENT DESCRIPTION AND PROBABLE CONSCOUENCES h 1012ll During normal operation at steady state power of 2300 MWt oDerators dis-l 0 3 l covered the "A" Drywell 112 - 02 analyzer had failed.

Upon investigation it was I

ggl found the analyzer was giving a false high 09 reading due to an incorrect l

O s l reagent gas flow. The "B" analyzer was operabic. Tech Spec 3.3.6-4 allows 30 l

l0 lc l l days operation with one analper inoperable.

There were no effects upon public l

l0 l7l l health or safety due to this event. This is-a repetitive event as last l

I O Ia l l reported on R0 Report No. 50-366/1980-009.

l 60 7

8 9 C DE CODE SUBOO E COYPONENT CODE SL8C dE S

E lDl9]

[S lE l@ y@ l El@ l Il Nl S l Tl Rl Uj@ lC l@ lZ l@

v 8

9 10 11 12 12 18 19 20 SEOUEN TI AL OCCURRENCE REFORT REVISION

,_ EVENT YE AR REPORT NO.

CODE TYPE N O.

h,"LE Fi'f40l 8l 0l l_l l 111l 8]

y l0l3l y

b W

u'[gni j

.,_ 21 22 23 24 26 27 28 23 30 31 32 Kit A

O P t

HOURS 22 S8 IT FOR UB.

$ PLIE 5 MAN ACTLRER lE lgl34Z lg l33 Z [g l36Zl@ l 0l 0l 0l l gg l N jg l A lg l B l 4 l 4 l 0 lg 33 3'

40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h l The cause has been attributed to instrument drif t of the reagent gas flowmeter l

i O l3 iij l which is a Ikooks MOdel 1350. The reagent gas flow was adjusted to the i

l correct flow rate and the analyzer was returned to service.

l l

,11 131 l 1 4 l

l

'D 8 9 80

$1 5

% POWE R oTHE R ST ATUS DIS O FY DISCOVERY DESCRIPTION l E l@ l 0l 9 l 4lgl N/A l

W @l Operator Observation l

i s ACTIVITY CONTENT REL E ASED OF fit L E ASE AMOUNT OF ACTIVITY LOCATION OF RELE ASE y @ ggl N/A l

l N/A l

1 6 7

8 9 10 11 44 45 80 PE RSONNEL E XPOSURES I

NUU8E R TYPt DE SCRIP TION 33 li I 711010 l0 l@l Z l@l N/A l

i' PotSONd',NJES DESCniPnON@

l NovetR li ln l l 0 l 0 l 0 lgl N/A l

l7 8 9 11 12 80 LOSS OF OR DAYAGE TO FACellTY 1 YPI DESCRIP110N v

E lZJ@l N/A l

7 8 'J _

10 80 EE) [U@llElCR,PuO~@8008260 6 %

I"'"' '

N/A l

l l l l l l l l l l l l l r.;

7 8 9 to 68 69 80 5 NAME OF PREPARER PHONE:

r l

l 1

NARRATIVE

REPORT Georgia Power Company i

plant E. 1. llatch Baxicy, Georgia 31513 Reportable Occurrence Report No. 50-366/1980-118 2300 11W on August 4, 1980, during normal operation at a steady state power of thermal the operator discovered that the "A" Drywell 110,, analyzer had failed.

2 Upon investigation it was discovered the analyzer was giving a high 0 reading 2

due to an incorrect reagent gas flow. The "B" analyzer was operable and still in service. Tech Spec 3.3.6.4 requires two analyzers in service or be restored to operable status within 30 days. There were no ef fects upon public health or safety due to this event. This is a repetitive event as last reported on Reportable Occurrence Report 50-366/1980-009.

The cause has been attributed to instrumet.t drif t of the reagent gas flovmeter i

t which is a Brooks Model 1350. The reagent gas flow was adjusted to the correct flow rate and the analyzer was returned to service.

l The operation of the plant was not af fected. Unit II is the only unit that utilizes this type of analyzer, Consip Delphi !!odel K-4.

No inherent problems i

were found during the generic review.