Forwards Eg&G Idaho,Inc Rept, Electrical,Instrumentation & Control Aspects of Override of Containment Purge Valve Isolation & Other Safety Feature Signals. Tech Specs Should Require That Purge Valves Be Closed When Unit Is Operating
ML19344D886
Person / Time
Site: Arkansas Nuclear 
Issue date: 08/14/1980
From: Novak T
Office of Nuclear Reactor Regulation
To: Cavanaugh W
ARKANSAS POWER & LIGHT CO.
Shared Package
ML19344D887 List:
References
NUDOCS 8008260263
Download: ML19344D886 (3)


Text

,-

T

/

pn rec

%yG d

4 UNITED STATES f};,c/(h NUCLEAR REGULATORY COMMISSION

.p

/. ;

wAssincrow. o. c. 20sss N+v

/

August 14. 1980 Docket No. 50-313 Mr. William Cavanaugh, III Vice President, Generation and Construction Arkansas Power & Light Company P. O. Box 551 Little Rock, Arkansas 72203

Dear Mr. Cavanaugh:

By letter dated Deces er 29, 1978, as supplemented by letters dated January 30, April 2, Deceder 12, 1979 and February 22, 1980, you responded to the NRC's letter of November 29, 1978 concerning "Contain-ment Purging During Normal Plant Operations" at Arkansas Nuclear One, Unit No. 1 (ANO-1). The enclosed report (EGG-EA-5141) was prepared for us by EG8G, Idaho Falls, Idaho, under contract to us as part of our technical assistance program. This report provided a technical evalua-tion of the electrical instrumentation and control design aspects of the override of containment purge valves isolation and other engineered safety feature actuation signals and is based upon review of the design aspects against the six staff review guidelines provided for the review.

The isolation valves for venting and purging satisfy the staff review guidelines cited above, with two exceptions. The exceptions, cited in the report, are that containment isolation should be initiation by high radiation in addition to safety injection and containment high pressure l

and that the radiation monitors that initiate containment isolation should i

be safety-grade as recomended by Guideline Nos. 4 and 5 respectively. The report also concludes that the Technical Specifications (TSs) for ANO-1 should require purge valves be clo' sed whenever the unit is operating.

The NRC staff has reviewed your submittals and the enclosed consultant's technical evaluation. The staff agrees with the conclusion of the consul-tant that the electrical, instrumentation and control design aspects of the override of the containment purge valve isolation and other engineered safety features actuation signals are acceptable. The staff also agrees with the consultant's conclusions that containment isolation at ANO-1 should be i

l initiated by high radiation in addition to safety injection and high contain-ment pressures and that the TSs for ANO-1 should require the purge valves be closed whenever the unit is operating. The staff, however, wishes to l

clarify the consultant's conclusion that the radiation-monitoring equipment should be required to be qualified as safety-grade equipment at this time.

l l

l l

8008260 M3

~

Arkansas Power & Light Company ccw/ enclosure (s):

Mr. David C. Trimble Manager, Licensing Arkansas Power & Light Company P. 0. Box 551 Director, Bureau of Environmental Little Rock, Arkansas 72203 Health Services 4815 West Markham Street Mr. James P. O'Hanlon Little Rock, Arkansas 72201 General Manager Arkansas Nuclear One P. O. Box 608 Russellville, Arkansas 72801 Mr. William Johnson U.S. Nuclear Regulatory Cornission P. O. Box 2090 Russellville, Arkansas 72801 Mr. Robert B. Borsum Babcock & Wilcox Nuclear Power Generation Division Suite 420, 7735 Old Georgetown Road Bethesda, Maryland 20014 Mr. Nicholas S. Feynolds Debevoise & Liberman 120017th. Street, NU Washington, DC 20036 '

Arkansas Polytechnic College Russellville, Arkansas 72801 Honorable Ermil Grant Acting County Judge of Pope County Pope County Courthouse Russellville, Arkansas 72801 Mr. Paul F. Levy Director Arkansas Department of Energy 3000 Kavanaugh Little Rock, Arkansas 72205 Director, Technical Assessment Division e'

Office of Radiation Programs (AW-459)

U. S. Environmental Protection Agency Crystal Mall #2 Arlington, Virginia 20460 U. S. Environmental Protection Agency Region VI Office ATTN:

EIS COORDINATOR 1201 Elm Street First International Building Dallas, Texas 75270 e-9--

--*--m

-4w,,.

-e-ee

-e

,,,-w-e,--

wi

-r e-w-

v-se-sir