' s~
S'\\)?
fj lowa Electric Light and her Company e o,g
/f
'A g %/[/
April 28, 1981 A.
DAEC-81-270 E
i, d
kiqy 0 U
1 Igg u.x klJg, eI o
Mr. James G. Keppler, Dire'ctor
[
tu Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission - Region III 799 Roosevelt Road Glen Ellyn, IL 60137
Subject:
Licensee Event Report No.80-036 UPDATE REPORT:
'(30 day)
Previous Report Date 8-15-80 File:
A-ll8a
Dear Mr. Keppler:
In accordance with Appendix A to Operating License DPR-49, Technical Specifications and Bases for Duane Arnold Energy Center and Regulatory Guide 10.1, please find attached a copy of the subject Licensee Event Report.
(Total of 3 copies transmitted).
Very truly yours, Daniel L. Mineck Chief Engineer Duane Arnold Energy Center Di}!/MSR/pl Docket 50-331 attachment cc:
Director, Office of Inspection and Enforcement (30)
U. S. Nuclear Regulatory Commission Washington, D. C.
20555 Director, Management Information.and Program Control (3)
U., S. Nuclear Regulatory Commission
. Washington, D. C.
20555 U. S. Nuclear Regulatory Commission g
c/o Document Management Branch Washington, D. C.
20555 cedar ane5se, kma suas
. aos ss v
e
[.
a
|
|---|
|
|
| | | Reporting criterion |
|---|
| 05000331/LER-1980-011, Forwards Updated LER 80-011/01X-1 | Forwards Updated LER 80-011/01X-1 | | | 05000331/LER-1980-011-01, Lower Crankshaft Main Thrust Bearing Found Wiped on Thrust & Journal Surfaces During Annual Insp of Standby Diesel Generator 1G-21.Caused by Startups W/Low Oil in Lube Oil Sump.Bearing Replaced | Lower Crankshaft Main Thrust Bearing Found Wiped on Thrust & Journal Surfaces During Annual Insp of Standby Diesel Generator 1G-21.Caused by Startups W/Low Oil in Lube Oil Sump.Bearing Replaced | | | 05000331/LER-1980-012, Forwards Updated LER 80-012/01X-1 | Forwards Updated LER 80-012/01X-1 | | | 05000331/LER-1980-012-01, Standby Diesel Generator 1G-31 Lower Crankshaft Thrust Bearing 13 Was Found Wiped on Journal Surface.Caused by Bearing/Crankshaft Clearance Out of Spec & Low Oil Sump Level.Sump Filled.Bearing Replaced | Standby Diesel Generator 1G-31 Lower Crankshaft Thrust Bearing 13 Was Found Wiped on Journal Surface.Caused by Bearing/Crankshaft Clearance Out of Spec & Low Oil Sump Level.Sump Filled.Bearing Replaced | | | 05000331/LER-1980-036, Forwards Updated LER 80-036/03X-1 | Forwards Updated LER 80-036/03X-1 | | | 05000331/LER-1980-036-03, During Power Ascension Following Shutdown,Rod Block Monitor B Failed.Caused by Improperly Seated Pin Connector at Rod Select Matrix Panel. Protective Panel Installed Over Pins.Pin Connectors Seated | During Power Ascension Following Shutdown,Rod Block Monitor B Failed.Caused by Improperly Seated Pin Connector at Rod Select Matrix Panel. Protective Panel Installed Over Pins.Pin Connectors Seated | | | 05000331/LER-1980-044, Forwards Updated LER 80-044/03X-1 | Forwards Updated LER 80-044/03X-1 | | | 05000331/LER-1980-044-03, /03X-1:on 800824,rod Block Monitor B Began Indicating Downscale Causing Continuous Rod Withdrawal Block.Caused by Improperly Seated Pin Connector at Rod Select Matrix Panel.Connector Seated | /03X-1:on 800824,rod Block Monitor B Began Indicating Downscale Causing Continuous Rod Withdrawal Block.Caused by Improperly Seated Pin Connector at Rod Select Matrix Panel.Connector Seated | | | 05000331/LER-1980-045-03, Condensate Storage Tank a Low Level Switch LS-5218 Was Found Inoperable.Caused by Corrosion on Probe Leads Due to Moisture.Leads Dried, Cleaned & Reconnected | Condensate Storage Tank a Low Level Switch LS-5218 Was Found Inoperable.Caused by Corrosion on Probe Leads Due to Moisture.Leads Dried, Cleaned & Reconnected | | | 05000331/LER-1980-045, Forwards Updated LER 80-045/03X-1 | Forwards Updated LER 80-045/03X-1 | | | 05000331/LER-1980-054, Forwards Updated LER 80-054/01X-1 | Forwards Updated LER 80-054/01X-1 | | | 05000331/LER-1980-054-01, During Plant Startup, Leaking Relief Valve PSV-4405 Stuck Open Causing Reactor Scram.Cause Unknown.Pilot Assembly Replaced | During Plant Startup, Leaking Relief Valve PSV-4405 Stuck Open Causing Reactor Scram.Cause Unknown.Pilot Assembly Replaced | | | 05000331/LER-1980-055, Forwards LER 80-055/01T-0 | Forwards LER 80-055/01T-0 | | | 05000331/LER-1980-055-01, /01T-0:on 801110,main Steam Relief Valve Stuck Open Resulting in Rx Scram.Caused by Wiring Error During 1980 Design Change Work & Inadequate post-installation Testing.Error Corrected & Test Procedure Revised | /01T-0:on 801110,main Steam Relief Valve Stuck Open Resulting in Rx Scram.Caused by Wiring Error During 1980 Design Change Work & Inadequate post-installation Testing.Error Corrected & Test Procedure Revised | | | 05000331/LER-1980-065-03, During Surveillance Testing Suppression Chamber Purge Inlet Valve CV-4308 Would Not Cycle,As Required by Tech Spec 3.7.D.1.Caused by Sticking Operator Mfg by Miller Fluid Power | During Surveillance Testing Suppression Chamber Purge Inlet Valve CV-4308 Would Not Cycle,As Required by Tech Spec 3.7.D.1.Caused by Sticking Operator Mfg by Miller Fluid Power | | | 05000331/LER-1980-065, Forwards Updated LER 80-065/03X-1 | Forwards Updated LER 80-065/03X-1 | |
|