05000260/LER-1981-016-03, /03L-0:on 810406,scram Discharge Tank Level Switch 2-LS-85-45A Setpoint Exceeded Tech Spec.Caused by Setpoint Drift.Switch Recalibr & Will Be Replaced

From kanterella
(Redirected from ML19343D357)
Jump to navigation Jump to search
/03L-0:on 810406,scram Discharge Tank Level Switch 2-LS-85-45A Setpoint Exceeded Tech Spec.Caused by Setpoint Drift.Switch Recalibr & Will Be Replaced
ML19343D357
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 04/27/1981
From:
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19343D347 List:
References
LER-81-016-03L, LER-81-16-3L, NUDOCS 8105040337
Download: ML19343D357 (2)


LER-1981-016, /03L-0:on 810406,scram Discharge Tank Level Switch 2-LS-85-45A Setpoint Exceeded Tech Spec.Caused by Setpoint Drift.Switch Recalibr & Will Be Replaced
Event date:
Report date:
2601981016R03 - NRC Website

text

U. S. NUCLEAR RE*,ULATORY COMMISSION NRC FOIM 366*

LICENSEE EVENT REPORT

~

.s l

l l

l l

l (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATIONI gNTROL BLOCK:

l o l i l l A ] L l B l R l F l 2 l@is0 l 0 l-l 0 l 0 l 0 l 0 l 0 l-l0 l 0 [Q 4l 1l 1l 1l 1l@ 7 CAT 58lJg LsCENSE NUMSER 2S 26 LICENSE TYPE Jo 5

14 7

8 9 LICENSEE CODE y',g l L j@l 015 l 0 l 0 l 0 l 2 l 6 l 0 @l 0 l 4 l 0 l6 l 8 l1 ]@l0 l 4 l 2 l 7 l 8 l1 l@

CON'T lolil 60 61 DOCKET NUMSER 68 69 EVENT DATE 74

'IS REPORT OATE 80 7

8 EVENT DESCRIPTION AND PROBA8LE CONSEQUENCES h l

I During normal operation while performinz SI 4.1. A-B (Reactor Protection Systein f o l2i (open I

l high water level in scram discharge tank), level switch 2-LS-85-45A setpoint lo ;3l There l

foT7] 1 on rise) was found at 51.5 gallons, exceeding T.S.3.1. A limit of 50 gallons.

[ o,, j iwas no eff ect on the health or safety of the public.

2-LS-85-45B, C, and D were l

Previous similar events

1 l o is i I operable. There were no significant resulting events.

J o i 7 ) l BFRO-260/81002, 81001, 80058: 259/8051, 7911, 8052: 296/8112.

l I

lo !a l I e0 E

CE SusCO E COMPCNENT CODE SUS O'E SU E

l R l B j@ l_Ej@ Wh l Il Nl Sl Tl RI Ulh ]@ W @

Io}9l 7

8 9

to 11 12 13 18 19 20 SEQUENTIAL OCCURAENCE REPORT REVISION LE4.8C EV ENT VE AR REPORT No.

CODE TYPE No.

@,aEgg l2f8 l1 l l-l l 0l 1l 6l y

l0l3l lL [

l-l W

22 2J 24 26 27 28 23 30 31 32 N ACT C o PLA T M

HOURS SB 1 Po 8.

SU LE MA PC RER IB l@l A]g l35 Zlg y@

l 0] 0l 0l 0[

]g

]g yg l Rl 2 l 9 l 0lg 33 J4 36 33 40 el 42 43 44 47 CAUSE CESCRIPTION AND CORRECTIVE ACTIONS h

) o l l Level switch 2-85-45A (Robertshaw Model SL-305-EI-X) setpoint exceeded T.S. 3.1. A I

ji lil: 1111mit because of setpoint drift. The switch was recalibrated and functionally I

rTT q l tested for repeatability. Recurrence control: replace switch with an analog l

l 1ii3l l switch on DCR 1398.

J LL.L_1 I ST S

% PCWER OTi4ER STATUS 65 0 Y

OtSCoVERY DESCRIPTION liI5llEl@ l1l0l0]@l NA l

l B l@l Surveillance test l

' ACTiviTv CO'0 RENT toCATioN OP REtEASE @

AMOUNT OP ACTiviTv @ l

.Ett. SED O a u tASE NA l

NA J

li 6 6 I Lz_1 @ Lz_J@l

.Easc~Na n.C,SSES DESCR,.7,0N@

Nyt,8ER

,.E l

l j il l 0 l 0 l 0 l@l Z l@l NA PEMSCNNEL NJu ES NUMBE4 DESCRIPriON l

li l 4 l[010i0!@l NA 80 r

s 3 11 82 WS$ OF OR OaMAGE TO 8 ACWTV tvst CESCRIPT!ON I

L'hJ W@l NA SO i

4 9 10 llllllll1IIIl$1 in E CRIPTION W dyt @l NA l

68 69 50,

i 4 g 10 PHONE-NAME CF #REPARER 810504o337

c, Tennessee Valley Authority Form BF-17 Browns Ferry Nuclear Plant BF 15.2 3/24/81 LER SUPPLEMENTAL INFORMATION

(..

3.1.A BFRO-50 260 / 81016 Technical Specification involved Reported Under Technical Specification

6. 7. 2. b (1)

Date of Occurrence 4/6/81 Time of Occurrence 1300 Unit 2

Identification and Description of Occurrence:

~

Level switch 2-LS-85-45A setpoint was found to be 51.5 gallons (open on rise) while performing SI 4.1.A-B.

The T.S. limit is 2.50 gallons.

Conditions Prior to Occurrence:

Unit 1 @ 94%

LMt 2 @ 100I Unit 3 @ 100%

Action specified in the Technical Specification Surveillance Requirements met due to inoperable equipment. Describe.

M r-Apparent Cause of Occurrence:

~~

Setpoint drift i

Analysis of Occurrence:

There was no damage to plant equipment. There was no activity release, no personnel exposure or injury and no danger to the health or safety of the public.

Corrective Action

t Recalibrated the Robertshaw Model SL-305-EI-I and tested for repeatability. This r-switch will be replaced with an analog switch on DCR 1398.

Failure Data:

BFR0 260/81002, 81001, 80058; 259/8051, 7911, 8052; 296/8112

  • Retention: Period - Lifetime; Responsibility - Document Control Supervisor

~~

  • Revision:

c i

s

,.m 9

e.

y.

..-4

,yf,.,

v e

- e a