AO 73-08:23 Steam Generator Seismic Support Holddown Bolts Found Broken or Bolt Head Raised Up from Ring Girder Flange as If Backed Off Several Turns.Caused by Thread Overstress. Bolts to Be Replaced Using Full QA & QC Procedures
ML19343C338
Person / Time
Site: Haddam Neck File:Connecticut Yankee Atomic Power Co icon.png
Issue date: 09/28/1973
From: Hartley F
CONNECTICUT YANKEE ATOMIC POWER CO.
To: Anthony Giambusso
US ATOMIC ENERGY COMMISSION (AEC)
References
AO-73-08, AO-73-8, CYH-2476, NUDOCS 8103100291
Download: ML19343C338 (2)


Text

RegU!atTf Lv$02 53 50-213 C-[~

CONNECTICUT YANKEE AT O M I C POWER COMPANY HADDAM NECK PLANT RR 21. BOX 127E. EAST HAMPTON, CONN. 06424 k

eptember 28, 1973 8' S N CYH-2476 a'~

7. /.

e

~

~

N

/*

Mr. A. Giambusso D

6 l'

s C

f Deputy Director for Reactor Projectk/

p\\ \\#

Directorate of Licensing Y jO'

.j j _^

j[ y' - /

iy.gge U. S. Atomic Energy Commission n

J, i-

~

Office of Regulation

/

( x '- a,

/

'I ~Q".

Dear Mr. Giambusso:

In accordance wit.1 Section 5.7.2 of the Connecticut Yankee Technical Specifications the following report involving failure of steam generator seismic support hold-down bolts is hereby sub-mitted as Abnormal Occurrence Number 73-8.

The Connecticut Yankee steam generator supports consist of a 13' - 11" I.D. x 14' - 11 1/2" 0.D.

truncated conical skirt 16' -

8.8" high furnished at its upper end with four radial linear ball bearing sliding blocks to which the steam generator mounting feet are bolted. At the lower end of the skirt eight linear ball bearing sliding blocks, all parallel to each other, and parallel to the skirt's radial center line to the reactor, fasten the skirt to its foundation. Each of the sliding block assemblies consists of

'wo fixed outer sections and a sliding inner section. The inner section is keyed to its mating outer sections through two linear ball bearing assemblies, that allow the inner section to translate without restriction but restrain it against the five remaining possible modes of motion. The fixed outer sections are bolted to the upper skirt ring girder in the case of the steam generator mounts and to the skirt support ring girder in the case of the skirt support mounts. Each of the fixed outer sections are keyed to its mating ring girder so that the hold-down bolts can only be tensily loaded.

During assembly, all of the hold-down bolts were equally pre-loaded to a level in excess of the maximum bolt load that could be induced in tha event of a design level earthquake or a primary loop piping rupture. The preloading was accomplished by heating the bolts and nuts in an electric oven to 725 F, inserting the bolt in place and, when thermocouple measurement showed that the bolt had cooled to 675/670 F, the nut was drawn up hand tight.

A total of 256 hold-down bolts are installed - 64 per steam generator. These bolts are approximately 2 5/8" in diameter by 3' long, threaded on one end. Twenty three bolts were found to be broken or with the bolt head' raised up from the ring girder 73i3

??03/662=7/

o-Mr. A. Giambusso September 28, 1973 flange--as if ~the-bolts were backed off several turns. Eight broken bolts have been identified and the remaining fifteen are also suspected of being broken. These twenty three are distrib-utedt

as follows: Ho.1 steam generator one (1); No. 2 steam generator eleven (11); No. 3 steam generator three (3); No. 4 steam generator eight (8).

The Architect-Engineer-Installer (Stone & k'ebster Engineering Corp.) has investigated these failures and reached the following conclusions:

"In our judgement, on review of the pattern of bolt failures, it is clear that those bolts that failed were set before cool-ing down to 675/670 F thereby overstressing the threads with resulting failure. Since less than 10% of all of the bolts have thus failed in a period of over seven years, it is clear that the metalurgy of the bolt material used is adequate for the designed preload applied and since this preload constitutes, the maximum possible loading that these bolts can be subjected too, they may be considered safe and the concept of overheating at installation of the 5% that did fail be accepted as the cause."

Although the Architect-Engineer initially stated that all bolts were required, analyses are presently being conducted to determine whether some number of bolt failures can be tolerated and still assure that the hold down support will satisfactorily perform its design function. For example, the No. I steam gen-erator support structure has only one (1) broken bolt out of sixty four (64).. '.

As bolt replacement is shown to be necessary, replacement will be accomplished with new bolts and nuts of the same material and heat treatment as the original installation using full quality assurance and control procedures in their manufacture and install-ation. Clearance holes will be required to be cut in the upper and lower flanges of the skirt lower ring girder to allow bolt replace-ment; analysis will also be completed to determine the extent of restoration required. Procedures will be developed before comencing repair activities. These will be performed using full quality assurance and control procedures.

A special report suimiarizing this repair activity will be submitted in accordance with section 5.7.3 of the Technical Specif-ications.

Very trtily yours, y