ML19343C044

From kanterella
Jump to navigation Jump to search
Forwards LER 81-010/03L-0
Date released: 12/23/2019 Download: ML19343C044


LER 81-010/03L-0:on 810113,w/unit at 100% Power,Overspeed Trip of Turbine Driven Auxiliary Feedwater Pump Occurred During Surveillance Testing.Caused by Failure of Turbine Governor to Control Speed.Governor Was Replaced
ML19343C052
Person / Time
Site: North Anna 
Issue date: 02/11/1981
From: Cartwright W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19343C052 (1)
Forwards LER 81-010/03L-0
ML19343C043
Person / Time
Site: North Anna 
Issue date: 02/11/1981
From: Cartwright W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19343C043 (2)