ML19343B429

From kanterella
Jump to navigation Jump to search
Forwards LER 80-049/03L-0
Date released: 12/23/2019 Download: ML19343B429


LER 80-049/03L-0:on 801119,containment Isolation Valve CFV-12 Would Not Close After Bubbling Nitrogen to CFT-1B. Caused by Broken Can in Torque Switch.New Switch Installed & Adjusted
ML19343B430
Person / Time
Site: Crystal River 
Issue date: 12/16/1980
From: Hernandez V
FLORIDA POWER CORP.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19343B430 (2)
Forwards LER 80-049/03L-0
ML19343B428
Person / Time
Site: Crystal River 
Issue date: 12/16/1980
From: Hancock J
FLORIDA POWER CORP.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19343B428 (1)