ff: :,
L.
L'. J;
~;
Telephons bl7 366-90\\\\
mi
/
m
,%, -. u.
\\A
. w....
g> t/,
n YANKEE ATOMIC ELECTRIC COMPANY 5 WW N
(,
RCCW ' ry
- Ta Cy.
30 20 Turnpoke Road Westboroughlhiassac'h*vsetts 01581
,Yxmxse ha Wya 74-48
[,L
!dj,9, December 5, 1974 United States Atomic Energy Co =ission f" " S I s
I!'
I,.
Washington, D.C.
20545 DEC101974 m
Attention: Directorate of Licensing
Subject:
Revised ECCS Evaluation
References:
1)
License 1:o. DPR-3 (Docket 1;o. 50-29),
2)
Proposed Change t;o. 117, " Revised ECCS Analysis",'N-.#
submitted to DOL /AEC on July 31, 1974
Dear Sir:
Pursuant to 10 CFR 50.46, a revised ECCS analysis
, performed in accordance with Appendix K, was submitted to the Directorate of Licensing on July 31, 1974. The following additional information is hereby forwarded to you as verbally requested by members of your staff on December 2, 1974.
As you already know, Westinghouse concludes that the worst single active failure during a loss-of-coolant accident (LOCA) is failure of a residual heat removal (RER) pu.p.
This is based on consideration of the effect of the failure on both energency core cooling (ECC) flow and con-tain ent heat removal capacity.
The Yankee !;uclear Power Staticn does not have power operated contain-ment cooling equipment. Thus, the worst single active failure was determined only cn the basis of its ef fect on ECC flow as su.marized below. Cceponents may be identified by referring to Figure 212.2-1 of the Final Hazards Sumary Report.
CC"PCNEI;T FAILURE CCISEQUEl:CES Valve 1:o. CS-MOV-536, Valve fails to close when 1;cne since series backups 537, 538, or 539 operator attempts closing (SI-MCV-22, 23, 24, or 25) if a break in a particular is provided.-
locp is indicated.
Valve :c. SI-MOV-1 Valvejailstocloseat Accumulator will blowdown 150 ft level of water somewhat further, however in the accumulator, relief valve operation will lower accumulator pressure.
SI-2 will prevent backficw when pressure decreases sono 20 bF9 f
m20
'TO:
'U.S. Atomic Energy Conmission WYR 74-48 Page Two
+
December 5, 1974 l
i i
Accumulator limit Failure to operate at Parallel redundant switch switches design level will operate.
f HPSI and LPSI pumps Failure of any one of the Reduced flow, however l
pumps to start SI system is designed for diesel failure which l
is a worse case.
I Diesel Failure of any one of One LPSI and one HPSI the diesels to start pump fail to start re-sulting in reduced flow.
Safety injection valves l
still operate since they l
are powered through an auto threwover switching arrangement.
l Valve No. SI-PR-58 Regulator fails closed Parallel redundant or 59 regulator supplies required flow.
Regulator fails open Not considered an active failure since to fail I
open the diaphram must fail.
i Accumulator pilot Fails to open Parallel backup operates.
operated relief (SI-15, 16)
In conclusion, the failure of an emergency diesel to start yields the greatest reduction of ECC flew and is the worst single active failure in 1
the referenced revised ECCS analysis.
Respectfully, i
l-YANKEE ATOMIC ELECTRIC COMPANY l
Y i
i D. E. Vandenburgh Vice President dm S
t h
..-a.+<
~
M AEC DISTRIBUTION FOR PART 50 DOCKET MATERI AL D EMPORARY FORM) 12410 CONTROL NO:
FILE:
FROM: Enkee Atocic Elec. Co.
DATE OF DOC DATE REC'D LTR TWX RPT OTHER
'Jestborcuch, Mass. 01531 12-5-Th 12-10.7h v
D. E. 'Jm 5 enbu,.9 TO:
ORIG CC OTHER SENT AEC PDR vv SENT LOCAL PDR EFL 3 signed 37 CLASS UNCLASS PROPINFO INPUT NO CYS REC'D DOCKET NO:
50-29
'co2 ho DESCRIPTION: Ltr pursuant to 10 CFR 50.46 ENCLOSURES:
furnishing addl info re CCCS info re Yid)C ltr cf T-31-74.......
.,e......... -,,. r.A zu O... $k PL ANT N ATi,1E: YAEC FOR ACTION /INFORMATION DHL 12-10-7h BUTLER (L)
SCHWENCER (L) ZIEMANN (L)
REG AN (E)
W Cca:es W/ Copies W/ Copies W/ Copies CLARK (L)
STOLZ (L)
DICKER (E)
LEAR (L)
W' Copies W/ Copies W/ Copies W/ Copies PARR (L)
VASSALLO (L)
KNIGHTON (E)
V/ Copies W/ Copies W/ Copies jPUjPLE (L)
W/ Ccpies YOUNGBLOOD (E)
KNIEL (L)
W/ Copies W(llfopies W/ Ccpies W/ Copics INTERNAL DISTRIBUTION TECH REVIEW CENTON LIC ASST A/T IND hG Fl@IX 4 et'TC GRIMES BR AITr/ AN GC. RC OM P-50EA SCHROEDER G AMMILL DIGGS (L)
SALTZMAN 1U NTZiN G/STAF F MACCARY KASTNER GE ARIN (L)
- 8. HURT ASE KNIGHT BALLARD GOULBOURNE (L) l AM BUSSO PAWLICKl SPANGLER KREt"icER (E)
PLANS LEF (L)
MCDONALD OYD SHAO g
- 00RE (L) (BWR)
MTELLOD)
ENVIRO M/oGRET (L)
CHAPMAN D E Y O U N G ( L) 8,?'.'.' R )
WOUSTON MULLER REED (E)
U B E===nem MOVHOLT iL)
MOVAK DICKER SERVICE (L) c COUPE dOLLER (L)
MOSS KNIGHTON e6HEPPAR D (L)
P. CO L LINS IPPOLITO YOUNGBLOOD SLATER (E)
D. THOMPSON (2)
D E TI S E TEDESCO REGAN SMITH (L)
KLECKER REG OFR LONG PROJECT LDR TEETS (L)
EISENHUT dFILE 5 REGION i LAI N AS WI L LI Ai.1S (E )
/
k MORRIS BENAROYA HA R LESS WILSON (L)
ST E E L E VOLlMER EXTERN AL DISTRIBUT!ON FCCC M
- 1. - L O C ", L P D R _. _ ___ __.
Li T :C ( A S E r, J-T.C i (1)(2)(10) - N ATIO'! AL L ASS 1 - POR SAN /L A/NY b(-7.5Z WUCH.s ;AN) 1 - ASLBP.E W Ea!: Rm E2E) 1 - BROOKH AVEN '!? T L AE 1_. t. s L E 1 - W. PE.N,NGTO:1, Rm E 201 GT 1 - G ULRsKSON. OR' L 1-:., e:.n u r.-
1 - BC.M Si..EE ROAD. Rm E 201 GT 1 - /,G T.1 E D ( R U T H G L S E */ A.. '
' IC -
CrSC L,J S r.
TO 1 - CC';Su c '. TS Rm S127 GT 1: 7. I " U. F C. J '-' 12-10-74 N E V. M A R /. E L J.'.i E
'.G C A ! A N 1 - R. D. f.;U E L LE F. R r E-::
2 GT