ML19343A081

From kanterella
Jump to navigation Jump to search
Forwards IE Info Notice 80-30, Potential for Unacceptable Interaction Between Control Rod Drive Scram Function & Nonessential Control Air at Certain GE BWR Facilities. No Specific Action or Response Requested
ML19343A081
Person / Time
Site: Grand Gulf  Entergy icon.png
Issue date: 08/19/1980
From: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Stampley N
MISSISSIPPI POWER & LIGHT CO.
References
NUDOCS 8009160036
Download: ML19343A081 (1)


Text

o.

gnerg UNITED STATES NUCLEAR REGULATORY COMMISSION O

na REGION ll

[f

~

g 101 MARIETTA ST., N.W., SUITE 3100

%g ATLANTA, GEORGIA 30303 In Reply Refer To:

I 8 1980 RII:JPO 7

50 4T6*

50-417 Sississippi Power and Light Co'opany ~

au ATTN:

N. L. Stampley Vice President of Production P. O. Box 1640 Jackson, MS 39205 Gentlemen:

This Information Notice is provided as an early notification of a possibly signi-ficant-matter.

It is expected that recipients will review the information for possible applicability to their facilities. No specific action or response is requested at this time. If further NRC evaluations so indicate, an IE Circular or Bulletin will be issued to recommend c,r request specific licensee actions. If you have questions regarding this matter, please contact the Director of the appro-priate NRC Regional Office.

Sincerely, James P. O'Reill Director

Enclosures:

1.

IE Information Notice No. 80-30 2.

List of Recently Issued IE Information Notices cc w/ encl:

C. K. McCoy, Plant Manager 8009160 C,*S 6

SSINS No.:6870 Accession No.:

8006190057 IN 80-30 UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 August 19, 1980 IE Information Notice No. 80-30:

POTENTIAL FOR UNACCEPTABLE INTERACTION BETWEEN THE CONTROL ROD DRIVE SCRAM FUNCTION 1

AND NON-ESSENTIAL CONTROL AIR AT CERTAIN GE BWR FACILITIES Continued NRC evaluation of possible failure modes of the control rod drive system related to the Browns Ferry event (IE Bulletin 80-17), has identified a potentially significant single failure mechanism which could degrade the scram function. The slow loss of non-essential control air pressure could degrade the scram function at certain facilities which have relatively poor communica-tion between the scram discharge volume (SDV) and the scram discharge instru-mented volume (SDIV) such that the SDIV drains more rapidly than the SDV drain rate into the SDIV.

The significance of such a si..;1e failure warrants transmission of an interim assessment by the NRC Office for Analysis and Evaluation of Operational Data as an early notification of a possibly significant matter that is still under review by the NRC staff.

It is expected that recipients will review the information for possible applicability to their facility.

No specific action or response is requested at this time.

If yoi have any questions regarding this matter, please contact the Director of the appropriate NRC Regional Office.