Responds to NRC Re Violations Noted in IE Insp Rept 50-483/80-27.Corrective Actions:Engineer Will Address All Questions in Surveillance close-out Memo & Not Rely on Info Stated in Surveillance Procedures
ML19341D234
Person / Time
Site: Callaway Ameren icon.png
Issue date: 02/02/1981
From: Bryan J
UNION ELECTRIC CO.
To: Fiorelli G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML19341D228 List:
References
ULNRC-414, NUDOCS 8103050192
Download: ML19341D234 (4)


Text

j

.' /^T k_)

UNION ELECTRIC COMPANY e

1908 GRATIOT STREET ST. Louis. Missoums JoMNOC.savAN O gom gas vaca pnessosset ST. Louse. edsesouns estee February 2, 1981

~

Mr. Gaston Fiorelli, Chief Reactor Construction & Engineering Support 3 ranch US Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, IL 60137 ULNRC-414

Dear Mr. Fiorelli:

INSPECTION REPORT NO. 50-48'/80-27 a

This is in response to your letter of January 6, 1981 reporting results of an inspection at Union Electric Company's callaway Plant Site on November 3-7 and 12-14, 1980 and as detailed in inspertion report number 50-483/80-27.

None of the material in the inspection report or in this response is considered proprietary by Union Electric Company.

This is a partial response to the items in Appendix A, Notice of Violation, of the inspection report.

Item 1-a is addressed in this letter.

We expect to provide a complete response to items 1 and 2 by February 18, 1981.

Our constructor, Daniel, is continuing to evaluate the items and is working on responses to them.

The following is in response to the items in Appendix A, Notice of Violation, of the inspection report.

1.) Severity Level V Violation (483/80-27-05) 10 CFR 50, Appendix B, Critorion XVI, stated in part, " Measures shall be established to assure that... defective material and equipment and nonconformances are promptly identified and corrected.

In the case of significant conditions adverse to quality, the measures shall assure that the cause of the condition is determined and correc-tive action taken to preclude repetition. "

81030 50 /9a2.

nse 4 es

e l

Mr.;Gaston Florelli

.3 -

February 2, 1981 Documentary evidence that the material and equipment conform-to the procurement requirements shall be

('

available at the nuclear power plant or fuel reprocess-l ing plant site prior to installation or use of such j

. material or equipment."

l

'Resoonse 9

This item will be responded to at a later date.

-If you have any question regarding this response or if additional ~information is required, please let me know.

l_rytrulyyours,LLa V

\\

P-John K B yan RHR/jds cc:

Mr. II. M. Wescott, NRC Region III Mr. W. A.

Ilansen, NRC Resident Inspector, Callaway Plant Missouri Public Service Commission 4

{

I e

4 i

~ _ _

.. _ ~.

's,.

)

)

SS l

CITY OF ST. LOUIS

)

Robert J.

Schukai,of_ lawful age, being first duly sworn l

upon oath says that he is General Manager-Engineering (Nuclear) for Union Electric Company; that he has read the foregoing document and knows the content thereof; that he has executed the same for and l

on behalf of said company with full power and authority to do so; i

and that the facts'therein stated are true and correct to the best of his knowledge, information and belief.

i By,

Robert J.

S hukai Genera ger-Engineering Nuclear SUBSCRIBED and sworn to before me this 2nd day of February, 1981 bHS b

0 ti:An3GET S. HDDA 2

Is0TO:Y FCJUO-STATE OF MISSOUR1 GT. LOU;S COUNTY MY C0:214:5310:4 EXPICES JANUARY 2.1982

'.s f

l 9

+y-w y

,?

Mr. Gaston Fiorelli 2-

. February 2, 1981 I

Contrary to the above, inadequate corrective' action was taken in the following instances:

a.

Surveillonce report 9/79-12 dated September 25, 1979, wr.s closed on November 12, 1980, even though two questions raised in the surveillance report requesting guidance on acceptance criteria for meas"*ing defects remained un-answered.

Response

Item a CORRECTIVE ACTION TAKEN AND THE RESULTS ACHIEVED:

The close out engineer considered tha't there was sufficient information in the surveillance to address both questions, however his close out did not address the two items in question.

He was instructed, on November 14, 1980, to address eJery open question in a surveillance close out memo, and not to rely on information stated in the surveillance.

The surveillance in question was reopened on January 23, 1981, and will remain so until the two outstanding questions have been adequately addressed, and closed out.

CORRECTIVE ACTION TO BE TAKEN TO AVOID FURTHER NONCOMPLIANCE:

We feel that the action stated above will avoid any recurrence of this noncon.pliance.

DATE WHEN FULL COMPLIANCE WILL BE ACHIEVED:

Full compliance was achieved on January 23, 1981.

Items b, c, and d These items will be responded to at a later date.

2.) Severity Level V Violation (483/80-27-06) 10 CFR 50, Appendix B, Criterion VII, stated in part, " Measures shall be established to assure that purchased material, equipment and services whether purchased directly or through contractors and subcontractors, conform to procurement documents.

These measures shall include provisions as appro-priate, for... examination of products upon delivery.

1

--