ML19341D054
| ML19341D054 | |
| Person / Time | |
|---|---|
| Site: | Sequoyah |
| Issue date: | 02/26/1981 |
| From: | Mills L TENNESSEE VALLEY AUTHORITY |
| To: | James O'Reilly NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| References | |
| 10CFR-050.55E, 10CFR-50.55E, NCR-SQN-CEB-800, NUDOCS 8103040775 | |
| Download: ML19341D054 (1) | |
Text
~ 5.'<h a = = = V. ' L T'
. J :, =
- a: n x - --, ( --
400 Chestnut Street Tower II iE]:
Q February 26, 1981 g
g 3
EB U
'M
% Qw #
i x
o Gf Mr.JamNes O'Reilly, Director N 5 Y
'[/
Office of Inhection and Enforcement
"[
U.S. Nuclear Risplatory Commission
'oi O ' <i g
Regian II - Suite 100 101 Marietta Street Atlanta, Georgia 30 '
1
Dear Mr. O'Reilly:
1 1
SEQUOYAH NUCLEAR PLANT UNIT 2 - INCORRECI INSULATICN WEIGHT USED IN PIPING ANALYSIS - NCR SCN CES 8008 - FOURTH INTERIM REPORT The subject deficiency was initially neported to NRC-0IE Inspector C. R. McFarland on April 24, 1980, in accordance with 10 CFR 50.55(e).
Interim reports were submitted on May 23, and October 16, 1980, and January 9, 1981.
TVA is continuing to review the as-constructed insulation drawings against the con:pleted analyses to determine if any reanalysis is required. We expect to submit our final report by April 8,1981.
If you have any questions, please get in touch with D. L. Lambert at FTS 857-2581.
Very truly yours, TENNESSEE VALLEY AUTHORITY L. M. Mills, Mat.ager Nuclear Regulation and Safety cc:
Mr. Victor Stello, Director Office of Inspection and Enforcement U.S. Nuclear Regulatory Conmiission Washington, DC 20555 g
_s
/
8103049ff s