ML19341C392

From kanterella
Jump to navigation Jump to search
Forwards Suppl 5 to IE Bulletin 80-17, Failure of Control Rods to Insert During Scram at Bwr. No Written Response Required
ML19341C392
Person / Time
Site: LaSalle  Constellation icon.png
Issue date: 02/13/1981
From: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Reed C
COMMONWEALTH EDISON CO.
References
NUDOCS 8103030292
Download: ML19341C392 (2)


Text

7669 orar 8

'c UNITED STATES 8"

O NUCLEAR REGULATORY COMMISSION n

,8.

{

.. E REGION 111 o

799 ROOSEVELT ROAD o

GLEN ELLYN, ILLINOIS 60137 February 13, 1981 Gentlemen:

Enclosed is IE Bulletin No. 80-17, Supplement 5, which is transmitted for information with regard to your nuclear power facility.

Should you have any questions regarding this bulletin supplement, please contact this office.

Sincerely a Mk kJamesG.Keppler V

Director

Enclosure:

IE Bulletin No. 80-17, Supplement 5 l

l

-l

-o.

1 t

Docket-No. 50-373 Docket No. 50-374 Commonwealth Edison Company ATTN:

Mr. Cordell Reed Vice President 3

Post Office Box 767 g

4 Chicago, IL 60690 S

cc w/ enc 1:

J. S. Able, Director p8

(

8

[7 of Nuclear Licensing

$ g 7I 0

/g9"3.

"j L. J. Burke, Site

/A j

Construction Superintendent g

%e T. E. Quaka, Quality Assurance Supervisor g

g R. II. llolyoak, Station Superintendent' B. B. S phenson, Project M

ger tral Files AD/ Licensing AD/ Operating Reactors AEOD Resident Inspector, RIII PDR Local PDR NSIC TIC Dean llansell, Office of Assistant Attorney General

SSINS No.: 6820 Accession No.:

801104259 IEB 80-17, Supp. 5 UNI'ED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C.

20555 February 13, 1981 IE BULLETIN N0. 80-17, SUPPLEMENT 5:

FAILURE OF CONTROL RODS TO INSERT DURING A SCRAM AT A BWR Description of Circumstances:

On July 3, 1980, the NRC issued IE Bulletin No. 80-17, that required actions to be taken by. licensees of all operating GE BWRs.

Among the actions required, Item 6(a) required a prompt notification report by telephone to the appropriate Regional Office followed by a telecopy or other written submittal.

These reports were required in the event that any of the systems (HPCI, RCIC, SLCS, RPT, RHR/ pool cooling, and main steam bypass) were found to be less than fully operable.

These reports have served the purpose of notifying NRC of cases of potential reduction in operability of systems important to the mitigation of consequences of an anticipated transient without scram (ATWS) event.

These reports are no longer necessary since improvements have been accomplished to increase the reliability of control rod scram.

Actions No longer Necessary by Licensees:

Further reporting is not required in response to Item 6(a) of IE Bulletin No. 80-17.

This does not change the reporting requirements set forth in your license technical specifications.

No written response to IE Bulletin 80-17, Supplement 5, is required.

If you have any questions regarding this matter, please contact the appropriate NRC Regional Office.

Attachment:

Recently issued IE Bulletins

Attachment IEB 80-17, Supp. 5 February 13, 1981 RECENTLY ISSUED IE BULLETINS Bulletin No.

Subject Date Issued Issued To 81-01 Surveillance of 1/27/81 All power reactor Mechanical Snubbers facilities with an OL

& to specified facilities with CP 80-25 Operating Problems with 12/19/80 All BWR facilities Target Rock Safety-Relief with an OL & specified Valves at BWRs near term OL BWR facilities & all BWRs with a CP Supplement 4 Failure of Control Rods 12/18/80 To specified BWRs to 80-17 to Insert During a Scram with an OL & All at a-BWR BWRs with a CP 80-24 Prevention of Damage 11/21/80 All power reactor Due to Water Leakage facilities with an Inside Containment OL or CP (October 17, 1980 Indian Point 2 Event) 80-23 Failures of Solenoid 11/14/80 All power reactor Valves Manufactured by facilities with Valcor Engineering OL or CP Corporation 80-22 Automation Industries, 9/11/80 All radiography Model 200-520-008 Sealed-licensees Source Connectors 80-?1 Valve yokes supplied by 11/6/80 All light water Malcolm Foundry Company, Inc.

reactor facilities with OLs or cps Supplement 3 Environmental Qualification 10/24/80 All power reactor to 79-01B of Class IE Equipment facilities with an OL Supplement 2 Environmental Qualification 9/30/80 All power reactor to 79-01B of Class 1E Equipment facilities with an OL OL = Operating License CP = Construction Permit