ML19341C387
| ML19341C387 | |
| Person / Time | |
|---|---|
| Site: | Big Rock Point File:Consumers Energy icon.png |
| Issue date: | 02/13/1981 |
| From: | James Keppler NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| To: | Dewitt R CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.) |
| References | |
| NUDOCS 8103030279 | |
| Download: ML19341C387 (2) | |
Text
}*
j'.
Docket No. 50-155 Consumers Power Company 1
ATTN:
Mr. R. B. DeWitt Vice President Nuclear Operations 212 West Michigan Avenue P
m/
e,3 Jackson, MI 49201
/({h<
R cc w/ enc 1:
S-D. P. Hoffman, Nuclear 3
"fgg 2 II98I A 1
Licensing Administrator 11I 7
C. J. Hartman, Plant ggron 9
Superintendent x,<,,
Central Files
/4 AD/ Licensing N
AD/ Operating Reactors AEOD 4
j Resident Inspector, RIII
{
'14 1 Ronald Callen, Michigan Public Service Commission s
810s030 / 79
A p irt
+4
'o UNITED STATES 8
NUCLEAR REGULATORY COMMISSION n
E REGION 111 799 ROOSEVELT ROAD
- 4.
o GLEN ELLYN,lLLINOIS 60137 February 13, 1981 Gentlemen:
The enclosed IE Bulletin No. 80-17, Supplement 5, is forwarded to inform you of actions that are no longer required. A written response to this supplement is not required.
If you desire additional information regarding this matter, please contact this office.
Sincerely O
d [
L' NM vfJames G. Keppler l
Director
Enclosure:
IE Bulletin No. 80-17, Supplement 5
SSINS No.: 6820 Accession No.:
801104259 IEB 80-17, Supp. 5 UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C.
20555
- f February 13, 1981 i
J IE BULLETIN NO. 80-17, SUPPLEMENT 5:
FAILURE OF CONTROL RODS TO INSERT c
DURING A SCRAM AT A BWR Description of Circumstances:
On July 3, 1980, the NRC issued IE Bulletin No. 80-17, that required actions to be taken by licensees of all operating GE BWRs.
Among the actions required, Item 6(a) required a prompt notification report by telephone to the appropriate Regional Office followed by a telecopy or other written submittal.
These reports were required in the event that any of the systems (HPCI, RCIC, SLCS, RPT, RHR/ pool c70 ling, and main steam byps'.1) were found to be less than fully operable.
These reports have served the purpose of notifying NRC of cases of potential reduction in operability of systems important to the mitigation _ of consequences of an anticipated transient without scram (ATWS) event.
These reports are no longer necessary since improvements have been accomplished to increase the reliability of control rod scram.
Actions No longer Necessary by Licensees; Further reporting is not required in response to Item 6(a) of IE Bulletin No. 80-]'.
This does not change the reporting requirements set forth in your license technical specifications.
No written response to IE Bulletin 33-17, Supplement 5, is required.
If you have any questions regarding this matter, please contact the appropriatt NRC Regional Office.
Attachment:
Recently issued IE Bulletins i
s
1 4
Attachmsnt IEB 80-17, Supp. 5 February 13, 1981 4
RECENTLY ISSUED IE BULLETINS Bulletin No.
Subject Date Issued Issued To 81-01 Surveillance of 1/27/81 All power reactor Mechanical Snubbers facilities with an OL
& to specified facilities with CP 80-25 Operating Problems with 12/19/80 All BWR facilities Target Rock Safety-Relief with an OL & specified Valves at BWRs near term OL BWR facilities & all BWRs with a CP i
Supplement 4 Failure of Control Rods 12/18/80 To specified BWRs to 80-17 to Insert During a Scram with an OL & All at a BWR BWRs with a CP 80-24 Prevention of Damage 11/21/80 All power reactor Due to Water Leakage facilities with an Inside Containment OL or CP (October 17, 1980 Indian Point 2 Event) 80-23 Failures of Solenoid 11/14/80 All power reactor Valves Manufactured by facilities with Valcor Engineering OL or CP Corporation 80-22 Automation Industries, 9/11/80 All radiography Model 200-520-008 Sealed-licensees Source Connectors 80-21 Valve yokes supplied by 11/6/80 All light water Malcolm Foundry Company, Inc.
reactor facilities with OLs or cps-Supplement 3 Environmental Qualification 10/24/80 All power reactor to 79-018 of Class 1E Equipment facilities with an OL Supplement 2 Environmental Qualification 9/30/80 All power reactor 4
to 79-01B of Class IE Equipment facilities with an OL OL = Operating License CP = Construction Permit