- E WASHINGTON, D. C. 20655 JAP.' 0 7 ggp Docket No. 50-409 LS05-81-1-004 2;
a Mr. Frank Linder General Manager Dairyland Power Cooperative 2615 East Avenue, South Lacrosse, Wisconsin 54601
Dear Mr. Linder:
RE: LACROSSE - SEP TOPIC V-10.A, " RESIDUAL HEAT REMOVAL SYSTEM HEAT EXCHANGER TUBE FAILURES" By letter dated January 11, 1979, we forwarded to you our draft evaluation of SEP Topic V-10.A.
You were requested to examine the facts upon which the evaluation was based and respond by confirming the facts were correct or by identifying any errors.
Since you did not connent on our draft evaluation, we assume that the facts'upon which the evaluation is based are correct.
We therefore, consider our evaluation of SEP Topic V-10.A to be final.
Sincerely, f
7M.
D nnis M. Crutch leid, ief Operating Reactors Branch #5 Division of Licensing cc: See next page O
1 t
I Mr. Frank Linder LA CROSSE BOILING WATER REACTOR DOCKET NO. 50-409 i
CC Fritz Schubert, Esquire Director Technical #ssessment Staff Attorney Division Dairyland Power Cooperative Of fice of Radiation Programs 2615 East Avenue South (AW-459)
La Crosse, Wisconsin 54601 U. S. Environmental Protection Agency O. S. Heistand, Jr., Esquire Crystal Hall #2 Morgan, Lewis & Bockius Arlington, Virginia 20460 1800 M Street, N. W.
Washington, D. C.
20036 U. S. Environmental Protection Agency Mr. R. E. Shimshak Federal Activities Branch La Crosse Boiling Water Reactor Region V Office Dairyland Power Cooperative ATTN: EIS COORDINATOR P. O. Cox 135 230 South Dearborn Street Genoa, Wisconsin 54632 Chicago, Illinois 60604 Coulee Region Energy Coalition Charles Bechhoef er, Esq., Chairman ATTN: George R. Nygaard Atomic Safety and Licensing Beard P. O. Box 1583 U. S. Nuclear Regulatory Comission La Crosse, Wisconsin 54601 Washington, D. C.
20555 La Crosse Public Library Dr. George C. Anderson 800 Main Street Department of Oceanography La Crosse, Wisconsin 54601 University of Washington Seattle, Washington 98195 U. 5. Nuclear Regulatory Comission Resident inspectors Office Mr. Ralph S. Decker Rural Route 71, Box 225 Route 4, Box 1900 Genoa, Wisconsin 54632 Cambridge, Maryland 21613 Town Chairman Dr. Lawrence R. Quarles Town of Genoa Kendal at Longwood, Apt. 51 Route 1 Kenneth Square, Pennsylvania 19348 Genoa, Wisconsin 54632 Thomas S. Moore Chairman, Public Service Comission Atomic Safety and Licensing Appeal Board of Wisconsin U. S. Nuclear Regulatory Comission.
Hill Farms State Of fice Building Washington, D. C.
20555 Madison, Wisconsin 53702 Ms. Anne K. Morse l
Alan S. Rosenthal, Esq., Chairman Coulee Region Energy Coalition I
Atomic Safety and Licensing Appeal Board Post Office Box 1583 U. S. Nuclear Regulatory Comission Lacrosse, Wisconsin 54601 Washington, D. C.
20555 U. S. Nuclear Regulatory Comission Mr. Frederick Milton Olsen,111 Resident Inspectors Office 609 North lith Street Rural Route #1, Box 225 Lacrosse, Wisconsin Genoa, Wisconsin 54632
.-