ML19340F021

From kanterella
Jump to navigation Jump to search
Forwards LER 80-066/03X-2
Date released: 12/20/2019 Download: ML19340F021


LER 80-066/03X-2:on 800805,core Spray Sys Pipe Break Detection Switches 14-DPIS-43A & 43B Found Set Above Tech Spec Level.Caused by Instrument Drift.Instrument Calibr & Returned to Svc
ML19340F043
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 01/12/1981
From: W. Verne Childs
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19340F043 (1)
Forwards LER 80-066/03X-2
ML19340F020
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 01/12/1981
From: Pasternak R
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19340F020 (1)