ML19340E787

From kanterella
Jump to navigation Jump to search
Forwards LER 80-042/03L-0
Date released: 12/20/2019 Download: ML19340E787


LER 80-042/03L-0:on 801211,control Rod Block Was Not Received as Required Per Tech Spec.Caused by Arm on GE Limit Switch Model CR-1156 Working Loose & Being Bent by Platform.Arm Straightened & Tightened
ML19340E789
Person / Time
Site: Vermont Yankee File:NorthStar Vermont Yankee icon.png
Issue date: 01/12/1981
From: Murphy W
VERMONT YANKEE NUCLEAR POWER CORP.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19340E789 (1)
Forwards LER 80-042/03L-0
ML19340E786
Person / Time
Site: Vermont Yankee File:NorthStar Vermont Yankee icon.png
Issue date: 01/12/1981
From: Murphy W
VERMONT YANKEE NUCLEAR POWER CORP.
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19340E786 (1)