05000366/LER-1980-121-03, /03L-0:on 801211,all Points of 1T47-RG11,drywell Temp Recorder,Were Reading Higher than Redundant Recorder 1T47-R612.Caused by Faulty Slide Wire Contacts & Printhead Mechanism.New Parts Installed

From kanterella
(Redirected from ML19340E221)
Jump to navigation Jump to search
/03L-0:on 801211,all Points of 1T47-RG11,drywell Temp Recorder,Were Reading Higher than Redundant Recorder 1T47-R612.Caused by Faulty Slide Wire Contacts & Printhead Mechanism.New Parts Installed
ML19340E221
Person / Time
Site: Hatch 
Issue date: 12/30/1980
From: Nix R
GEORGIA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19340E211 List:
References
LER-80-121-03L, LER-80-121-3L, NUDOCS 8101060669
Download: ML19340E221 (2)


LER-1980-121, /03L-0:on 801211,all Points of 1T47-RG11,drywell Temp Recorder,Were Reading Higher than Redundant Recorder 1T47-R612.Caused by Faulty Slide Wire Contacts & Printhead Mechanism.New Parts Installed
Event date:
Report date:
3661980121R03 - NRC Website

text

I NHC FORM CGG U. S. NUCLL AH HEGUL AT ORY COMMISSION (7 77)

LICENSEE EVENT REPORT CONTROL BLOCK: l l

l l

l l

h (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) lo lil lG l Al El IlH l ll@l 0 l Ol Oi 0l 0101010101010 l@l 4l ll ll 1l 1l@l l

l@

7 8 9 LICENSEE CODE 14 15 LICENSE NUM8kN h

26 LICENSE TY PE JO S i L A 3' 58 CON'T lolil

$'RC l L l@l 0 ] 510 l 01013 l 616 l@l ll 211 11 1810 l@l 11213 l 018 l 0 l@

7 8

60 61 DOCisET NUMBER 68 69 EVENT DATE 14 75 REPORT DATE 80 EVENT DESCRIPTION AND PROB ABLE CONSEQUENCES h lo l2l l With the plant in steady operation at 1942 MWT, all points of IT47-R611,I [O ;3 ; ; D rywel l Temperature Recorder, were found to be reading higher than l

Io l4i l redundant recorder IT47-R612.

Tech Spec 4.2-1 requires two operable l

lo isl l instrument channels.

The unit was placed in a 30 day limiting conditiong la ls l l of operation as a result of this event.

This a repetitive event as last lol71l reported on~ Reportable Occurrence Report No. 50-321/1980-75.

The health i o m i l and safety of the public was not af fected by this event.

I 80 7

8 9 SYSTEV

CAUSE

CAUSE COVP.

VALVE CODE CODE SUBCOCE COUPONENT CODE SUBCODE SUBCODE l0l9]

l I l Dl@ lE l@ l 8 l@ [I l Nl S l Tl R l Ul@ {@ y @

1 8

9 10 11 12 13 18 19 20 SEQUE NTI AL OCCURRENCE REPORT REVISION LE EVENTYEAR REPORT NO.

CODE TYPE NO, O aj,;R HO 1 8101 l_I 11 12l Il l/l l 01 31 l Ll l-l l0l o,1

_ 21 22 23 24 26 27 28 29 30 31 32 AK f ACT ON ON PL NT T D HOURS 22 SB IT D FOF UB.

SUPPLI MAN FA TURER lAl@lZl@

l Zl@

lZl@

l 0l 0 l 0] u l l Y l@

W@

lAl@

l Tl 0 l 3l 9 l@

33 J4 35 36 3/

40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS li lol l The cause of this event has been attributed to faulty slide wire con-l lilijitacts and printhead mechanism.

New parts were installed, the instrumenq i,i,,,Iwas recalibrated and returned to service.

Because of the poor relia-l l

i,i,i l bility of this recorder, a design change has been implemented to re-l l

l i,,Ai l place it with a more reliable instrument.

l 80 7

8 9 l

STA S

  • hPOWER OTHER STATUS ctSCO RY DISCOVERY OESCRIPTION li Is l l El@ l 01 7l 9l@]

N/A l

l B l@l Operator Observation l

I A TSVITY CO TENT RELE ASEO OF RELE ASE AVOUNT OF ACTIVITY LOCATION OF RELEASE liIcllZl@lZl@l N/A l

l N/A l

l PERSONNEL EXPOS ES f

NUV8E H TYPE DE SCRIP TION l i l 2 l l 010 l0 l@l Zl@l N/A l

PE R SON N E l. NJU IES NUV8EH OESCHipitON l i 1-l l 01 0 l0 l@l N/A l

7 8 9 ft 12 80 1 OLS OF OH DAVAGE TO FACillTY TVPE DE SC HIP T ION li 191 l Zl@l N/A l

7 6

'l 10 80 12 l o l I N j@I>'tSen.nioN@ 8101060 %

c.U E' ""

l N/A l

lllllllllllllj 7

8 9 TG 68 69 80 ;

NAVE OF PREPARER PHONE:

~

l L.

r s

LER No.:

50-321/1980-121 Licensee: Georgia Power Company Facility Name:

Edwin I. Hatch Docket No.:

50-321

Narrative

Report for LER 50-321/1980-121 With the plant in steady operation at 1942 MWT, all points of IT47-R611, Drywell Temperature Recorder, were found to be reading higher than redundant recorder IT47-R612.

Tech Spec 4.2-1 requires two operable instrument channels.

The unit was placed in a 30 day limiting condition of operation as a result of this event.

This is a repetitive event as last reported on Reportable Occur-rence No. 50-321/1980-75.

The health and safety of the public was not affected by this event.

The cause of this event has been attributed to faulty slidewire contacts and printhead mechanism.

New parts were installed and the instrument was recali-brated and returned to service.

Because of the poor reliability of this re-corder, a design change has been implemented to replace it with a more reli-able instrument.

The generic review did not reveal any inherent problems. Unit II does not use this type of recorder.

l I

\\