ML19340D647
| ML19340D647 | |
| Person / Time | |
|---|---|
| Site: | Trojan File:Portland General Electric icon.png |
| Issue date: | 11/20/1980 |
| From: | Crews J NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V) |
| To: | Withers B PORTLAND GENERAL ELECTRIC CO. |
| Shared Package | |
| ML19340D648 | List: |
| References | |
| NUDOCS 8012310535 | |
| Download: ML19340D647 (2) | |
See also: IR 05000344/1980026
Text
. -
--
--
-
-
.
@ 81tGg
[
o
UNITED STATES
'g
[N
g
NUCLEAR REGULATORY COMMISSION
j
REGION V
r;
c
o,
1990 N. CALIFORNIA DOULEVARD
%
,,,e
SUITE 202, WALNUT CREEK PLAZA
+
WALNUT CREEK, CALIFORNI A 94596
iMV 2 ' $20
.
Docket No. 50-344
4
Portland General Electric Company
121 S. W. Salmon Street
Portland, Oregon 97204
4
Attention: Mr. Bart D. Withers
Vice President, Nuclear
Gentlemen:
Subject: NRC Inspection of the Trojan Nuclear Plant
This refers to the inspection conducted by Messrs. M. H. Malmros and G. W.
Johnston of this office on October 1-31, 1980, of activities authorized by
NRC License No. NPF-1, and to the discussion of our findings held by Messrs.
Malmros and Johnston with Mr. Yundt and other members of your staff periodically
during the inspection.
Areas examined during this inspection are described in the enclosed inspection
report. Within these areas, the inspection consisted of selective examinations
of procedures and representative records, interviews with personnel, and
observations by the inspectors.
!
No items of noncompliance with NRC requirements were identified within the
i
scope of this inspection.
In accordance with Section 2.790 of the NRC's " Rules of Pratice," Part 2,
Title 10, Code of Federal Regulations, a copy of this letter and the enclosed
inspection report will be placed in the NRC's Public Document Room.
If this
report contains any information that you believe to be proprietary, it is
necessary that you submit a written application to this office, within 20
days of the date of this letter, requesting that such information be withheld
from public disclosure. The application must-include a full statement of
the reasons why it is claimed that the information is proprietary. The-
application should be prepared so that any proprietary information identified
is contained .in an enclosure to the application, since the application without
the enclosure will also be placed in the Public Document Room.
If we do not
i
hear from you in this regard within the specified period, the report will
be placed in the Public Document Room.
,
t
- 8012310535
-- -.
-. . -
--.
.
- - - - - - .. - .
- - -
,
NOV 2 01990
Portland General Electric Company
-2_
Should you have any questions concerning this inspection, we will be glad
to discuss them with you.
Sincerely,
/// '/?,0
I
.
/
J
f I
f
peactorOperationsand
,
Nuclear Support Branch
Enclosure:
IE Inspection Report
No. 50-344/80-26
cc w/o enclosure:
C. P. Yundt, PGE
F. C. Gaidos, PGE
J. W. Lentsch, PGE