Forwards IE Info Notice 80-37, Containment Cooler Leaks & Reactor Cavity Flooding at Indian Point Unit 2. No Written Response Required
ML19340C834
Person / Time
Site: Perry  
Issue date: 10/24/1980
From: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Davidson D
CLEVELAND ELECTRIC ILLUMINATING CO.
References
NUDOCS 8012170649
Download: ML19340C834 (1)


Text

_. - - - _

s* " 4 "t;. (

9'o UNITED STATES

~

! ' s yq NUCLEAR REGULATORY COMMISSION e

REGION 111 o,

f 790 ROOSEVELT ROAD g,.....,/

GLEN ELLYN ILUNOls 60m OCT 2 41990 Docket No. 50-440 Docket No. 504441 The Cleveland Electric Illuminating i

Company ATTN:

Mr. Dalwyn R. Davidson Vice President - Engineering P. O. Box 5000 Cleveland, OH 44101 Gentlemen:

This IE Infor:9ation Notice No. 80-37 is provided as an early notification of a possibly significant matter.

It is expected that recipients will review the information for possible applicability to their facilities. No specific action or response is requested at this time.

If further NRC evaluations so indicate, an IE Circular or Bulletin will be issued to recommend or request specific licensee actions.

If you have question, regarding this matter, please contact this office.

Sincerely, o.. n > A L L mes G. Kepp Director

Enclosure:

IE Information Notice No. 80-37 cc w/ encl:

Central Files Director, NRR/DPM Director, NRR/ DOR PDR Local PDR NSIC TIC Harold W. Kohn, Power Siting Commission Mr. Daniel D. Wilt, Attorney Helen Evans, State of Ohio

,--u..,~v


e

-r v v

r-

.w-~

f SSINS No.:

6835 Accession No.:

8008220249 UNITED STATES IN 80-37 NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 tg C October 24, 1980 IE Information. Notice No. 80-37:

CONTAINMENT COOLER LEAKS AND REACTOR CAVITY FLOODING AT INDIAN POINT UNIT 2 Discription of Circumstances:

This Notice contains information regarding multiple service water leaks into containment with resulting damage to reactor instrumentation and potential damage to the reactor pressure vessel.

Upon containment entry on October 17, 1980 at Incian Point Unit 2, to repair a malfunctioning power range nuclear detector, it was discovered that a significant amount of water was collected (approximately 100,000 gal) on the containment floor, in the containment sumps, and in tne cavity under the reactor pressure vessel (RPV).

This collected water probably caused the detector malfunction, and the water in the cavity under the RPV is believed to have been deep enough to wet several feet of the pressure vessel lower head, causing an unanalyzed thermal stress condition of potential safety significance.

This condition resulted from the following combination of conditions:

(1) Both containment sump pumps were inoperable., one due to blown fuses from an unknown cause and the other due to binding of its controlling float; (2) The two containment sump level indicating lights which would indicate increasing water level over the water level range present in the containment were stuck (on) and may have been for several days, leaving the operator with no operable instrumentation to measure water level in the contailment; (3) The moisture level indicators in the containment did not indicate high moisture levels, apparently because they are designed to detect pressurized hot water or steam leaks (i.e., a LOCA), and are not sensitive to the lower airborne moisture levels resulting from relatively small cold water leaks; (4) The hold up tanks which ultimately receive water pumped from the containment sump also receive Unit 1 process water, lab drain water, etc.

These other water sources masked the effect of cessation of water flows from the Unit 2 sump; (5) There were significant, multiple service water leaks from the containment fan cooling units directly onto the containment floor.

These coolers have a history of such leakage, which cannot be detected by supply inventory losses since the supply system (service water system) is not a closed system; (6) The two submersible pumps in the cavity under the Reactor Pressure Vessel were ineffective since they pump onto the con-tainment floor for ultimate removal by the (inoperable) contsinment sump pumps.

There is no water level instrumentation in the cavity under the RPV, nor was there any indication outside the containment when these pumps are running.

The licensee has installed redundant sump level annunciated alarms in the control room and has installed an annunciated alarm in the control room to indicate if either submersible pump in the reactor cavity activates.

The licensee has also repaired the service water leaks, installed guide bushings on the sump pump control floats to prevent their binding, and has repaired the cantainment sump water level indicators.

IN 80-37 October 24, 1980 i r Page 2 of 2 i

)

The licensee plans in the longer term to replace the containment fan unit cooling coils.

It is anticipated that results of a continuing NRC im stigati3n ihto this i

incident will result in issuance of an IE Bulletin ana 'or an ' ERR Generic Letter 'n the near future which will recommend or require srecific licensees and appHrant actions.

In the interim, we recommend that ai1 licensee ascertain tha* the potential does not exist for undetected water accumulation in the containment.

4 This Information Notice is provided to inform licensees of a possibly significant

~

matter.

No written response to this Information Notice is required.

i i

i J

IN 80-37 r

October 24, 1980 RECENTLY ISSUED IE INFORMATION NOTICES

~

Information Date of Notice No.

Subject Issue Issued to' 80-36

{ailure of steam 10/10/80 All nuclear power generator support bolting reacter facilities holding OLs or cps 80-35 Leaking and dislodged 10/10/80 All categories G and Iodine-124 implant seeds G1 medical licenstes 80-34 Boron dilution of reactor 9/26/80 All pressurized water coolant during steam reactor facilities generator decontamination holding power reactor OL 80-33 Determination of teletherapy 9/15/80 All teletherapy timer accuracy (G3) licem ees 80-32 Clarification of certain 8/12/80 All NRC and agreement requirements for Exclu-state licensees

'sive-use shipments of radioactive c.aterials 80-31 Maloperation of Gould-8/27/80 All light water r: actor Brown Boveri Type 480 facilities holding OLs volt type K-6005 and or cps K-DON 6005 circuit breakers 80-30 Potential for unaccept-8/19/80 All boiling water reactor able interaction between facilities holding power the control rod drive scram reactor OLs or cps.

function and non-essential control air at certain GE BWR 1

facilities 80-29 Broken studs on Terry 8/7/80 All light water reactor turbine steam inlet facilities holding flange power reactor OLs cr cps

  • Supplement to Notification of 7/29/80 All holders of reactor 80-06 significant events at and near-term OL operating power reactor applicants facilities 80-28 Prompt reporting of 6/13/80 All applicants for and required information holders of nuclear power to NRC reactor cps
  • Operating Licenses or Construction Permits